either all the way open or all the way closed
normally fully open
throttled depending on load
controlled by liquefied pressure
第1题:
around the engine
around the cooler
to the expansion tank
overboard
第2题:
open
close
remain in its position
flood the evaporator with refrigerant
第3题:
nonexistent
for controlling pressure
for controlling superheat
for controlling the solenoid valve
第4题:
foreman
operator
opener
stevedore
第5题:
inter cooler
cylinder
outlet pipe
inlet pipe
第6题:
with the axis of the solenoid horizontal, sensing temperature of the box, and upstream of the thermal expansion valve
upright, sensing temperature of the box, and upstream of the thermal expansion valve
upright, sensing temperature of the box, and downstream of the thermal expansion valve
upright, sensing heat of the tail coil, and upstream of the thermal expansion valve
第7题:
Dehydrators must be used continuously in a refrigeration system
A 25 ton refrigeration system has the same cooling effect as melting 25 tons of ice in 24 hours
A thermostatic expansion valve is used to control refrigerated space temperature
The liquid receiver functions to collect and remove non- condensable gases
第8题:
At the designed operating temperature, the liquid refrigerant charge has changed to a vapor
The liquid refrigerant tends to collect at the bellows or diaphragm and reduces the valve sensitivity
The sensing bulb is empty of liquid refrigerant charge at the designed operating temperature
The sensing bulb is never emptied of liquid refrigerant under normal operating conditions
第9题:
vapor
liquid
solid
None of the above is tree
第10题:
expansion valve to the compressor
receiver to the expansion coil
expansion valve to the evaporator
condenser to the expansion valve
第11题:
chief engineer
surveyor
the engineer
the technique personnel of the shipyard
第12题:
regulating the level of corrosion inhibitor in the primary cooling system
the level of the freshwater expansion tank
varying the engine load to meet temperature requirements
the operation of the thermostatic valve
第13题:
a low level in the engine expansion tank
excessively high coolant pressure
improper temperatures
malfunctioning of the jacket water heater
第14题:
king valve and the expansion valve
solenoid valve and expansion valve
evaporator and receiver
compressor and evaporator
第15题:
either all the way open or all the way closed
normally open
throttled depending on load
controlled by suction pressure
第16题:
The liquid receiver functions to collect and remove non-condensable gases
A thermostatic expansion valve is used to control refrigerated space temperature
Refrigerant temperature in an evaporator is directly related to refrigerant pressure
Dehydrators must be used continuously in a refrigeration system
第17题:
evaporator pressure decrease
evaporator coil over-feed
evaporator capacity increase
expansion valve diaphragm rupture
第18题:
return to a neutral position
flood the evaporator
open
close
第19题:
stop the refrigerant from flowing
force the refrigerant to flow
cause the refrigerant pressure to rise
cause the refrigerant pressure to fall
第20题:
the expansion valve will move toward the wide open position
the expansion valve will move toward the closing position
the feeler bulb will conveys the high temperature
the superheat degree will raise
第21题:
re-adjust the discharge pressure
clean the expansion valve screen
add refrigerant
adjust the expansion valve
第22题:
The expansion tank should be topped off
The thermostatic water regulating valves should be manually opened
The fuel filters should be changed
The engine should be turned over slowly with the indicator cocks open
第23题:
loose expansion valve control bulb
low differential setting on the H-Pcutout
blown fuse in the motor circuit
faulty suction pressure regulator