更多“If a refrigeration system compressor crankcase is sweating,”相关问题
  • 第1题:

    The sensing line for the low pressure cutout switch to a refrigeration system is located ______.

    A.in the chill box(冰箱)

    B.before the receiver

    C.on the suction side of the compressor

    D.on the discharge side of the compressor


    正确答案:C

  • 第2题:

    单选题
    The sudden reduction of pressure occurring within the crankcase of a refrigeration compressor during starting causes the ().
    A

    sudden evaporation of wax crystals in the lubricant

    B

    sudden evaporation of entrapped air in the lubricant

    C

    release of refrigerant from the oil/refrigerant mixture

    D

    release of dissolved lubricant from the refrigerant


    正确答案: B
    解析: 暂无解析

  • 第3题:

    单选题
    When liquid reaches the compressor of a refrigeration system through the suction line, the condition is called ().
    A

    flooding back

    B

    superheating

    C

    overflowing

    D

    recycling


    正确答案: C
    解析: 暂无解析

  • 第4题:

    单选题
    If a refrigeration crankcase compressor were short cycling on the low pressure cutout switch, the cause might be that the ().
    A

    system was overcharged with refrigerant

    B

    system was low on refrigerant

    C

    suction valves were leaking slightly

    D

    relief valve was leaking slightly


    正确答案: D
    解析: 暂无解析

  • 第5题:

    单选题
    The refrigeration compressor in a water cooled refrigeration system is short cycling on the high pressure cutout switch, One reason for this could be the ().
    A

    system is low on refrigerant

    B

    high pressure cutout switch is improperly adjusted

    C

    discharge valves are leaking slightly

    D

    discharge valves are leaking excessively


    正确答案: A
    解析: 暂无解析

  • 第6题:

    单选题
    If the refrigeration compressor crankcase is sweating, the cause may be due to ().
    A

    a shortage of refrigerant

    B

    the compressor running continuously

    C

    liquid refrigerant returning to the compressor

    D

    the compressor short cycling on the high pressure cutout


    正确答案: C
    解析: 暂无解析

  • 第7题:

    单选题
    Excessive oil foaming in the crankcase of a refrigeration compressor at start up can cause().
    A

    compressor damage from improper lubrication

    B

    refrigerant absorption by the lubricant

    C

    increased viscosity in the lubricant

    D

    carbon deposit on the compressor suction valves


    正确答案: C
    解析: 暂无解析

  • 第8题:

    单选题
    In the () refrigeration compressor one end of the crank shaft extends through the crankcase house for connection, via a coupling or pulley, to an external drive motor.
    A

    open-type

    B

    hermetic

    C

    semi-hermetic

    D

    all the above


    正确答案: C
    解析: 暂无解析

  • 第9题:

    单选题
    The purpose of the refrigeration system low pressure cutout switch is to ()
    A

    protect the compressor from liquid flood back

    B

    protect the compressor from low discharge pressure

    C

    start and stop the compressor upon system demand

    D

    start the compressor after a drop in the evaporator pressure


    正确答案: B
    解析: 暂无解析

  • 第10题:

    单选题
    An increase in the heat load to a refrigeration system will cause ().
    A

    the suction pressure to decrease

    B

    the suction temperature to increase

    C

    increased ice formation on the evaporator coil

    D

    excessive short cycling of the compressor


    正确答案: A
    解析: 暂无解析

  • 第11题:

    单选题
    The sensing line for the low pressure cutout switch to a refrigeration system is located ().
    A

    in the chill box

    B

    before the receiver

    C

    on the suction side of the compressor

    D

    on the discharge side of the compressor


    正确答案: C
    解析: 暂无解析

  • 第12题:

    单选题
    Excessive oil foaming in the crankcase of a refrigeration compressor is most likely to occur() when the compressor.
    A

    has continuously for a long period

    B

    suction pressure is below normal

    C

    oil level is below normal

    D

    starts after a long idle period


    正确答案: C
    解析: 暂无解析

  • 第13题:

    单选题
    Low compressor head pressure in a refrigeration system can be caused by().
    A

    insufficient condenser cooling water

    B

    excessive condenser cooling water

    C

    air in the refrigeration system

    D

    excessive refrigerant in the system


    正确答案: A
    解析: 暂无解析

  • 第14题:

    单选题
    A refrigeration system compressor crankcase is sweating or unusually coldThis is an indication of().
    A

    a shortage of refrigerant in the system

    B

    air in the system

    C

    an accumulation of liquid refrigerant in the crankcase

    D

    a shortage of oil in the crankcase


    正确答案: C
    解析: 暂无解析

  • 第15题:

    单选题
    Excessive oil foaming in the crankcase of a refrigeration compressor can result in ().
    A

    overheated compressor bearings

    B

    excess lube oil viscosity

    C

    carbon deposits on the compressor piston rings

    D

    wax crystals forming in the lubricant


    正确答案: A
    解析: 暂无解析

  • 第16题:

    单选题
    In a refrigeration system, foaming of the crankcase oil may cause the ().
    A

    expansion valve to overfeed

    B

    compressor to knock

    C

    water regulating valve to fail

    D

    crankcase drains to plug


    正确答案: B
    解析: 暂无解析

  • 第17题:

    单选题
    When a refrigeration compressor is in the ‘off’ cycle, the thermal expansion valve will().
    A

    always be wide open when the compressor restarts

    B

    continue to operate as if the system were in operation

    C

    remain open until evaporator pressure equalizes, then close until the compressor restarts

    D

    always be completely closed until the compressor restarts


    正确答案: B
    解析: 暂无解析

  • 第18题:

    单选题
    Foaming of the oil in a refrigeration compressor crankcase is caused by ().
    A

    refrigerant boiling out of solution from the lube oil

    B

    liquid refrigerant flooding the compressor and system

    C

    lube oil viscosity being reduced by refrigerant dilution

    D

    compressor suction pressure suddenly increasing


    正确答案: C
    解析: 暂无解析

  • 第19题:

    单选题
    Refrigerant entering the compressor of a refrigeration system should be in which of the following conditions?()
    A

    Sub-cooled liquid

    B

    Sub-cooled vapor

    C

    Superheated vapor

    D

    Liquid


    正确答案: B
    解析: 暂无解析

  • 第20题:

    单选题
    Crankcase sweating in a refrigeration system is caused by ().
    A

    a stuck solenoid valve

    B

    a shortage of refrigerant

    C

    too much oil in circulation

    D

    too much superheat


    正确答案: D
    解析: 暂无解析

  • 第21题:

    单选题
    The accumulation of air and other non-condensable gases in a refrigeration system will ().
    A

    cause a loss of the liquid seal

    B

    create a vapor lock in the liquid receiver

    C

    collect in the condenser

    D

    cause foaming of the oil in the crankcase


    正确答案: B
    解析: 暂无解析

  • 第22题:

    单选题
    Under normal conditions, the refrigerant enters the compressor in an operating refrigeration system as a ().
    A

    liquid

    B

    dry saturated gas

    C

    wet saturated gas

    D

    superheated vapor


    正确答案: D
    解析: 暂无解析

  • 第23题:

    单选题
    Sweating of the refrigeration system compressor crankcase is caused by ().
    A

    too much superheat

    B

    insufficient superheat

    C

    suction pressure too low

    D

    excessive refrigerant returning to the compressor


    正确答案: D
    解析: 暂无解析