Low compressor head pressure in a refrigeration system can be caused by ___.
A.insufficient condenser cooling water
B.excessive condenser cooling water
C.air in the refrigeration system
D.excessive refrigerant in the system
第1题:
Which of the following problems could cause the high pressure cutout switch to shut down the compressor in a refrigeration system?
A.A shortage of liquid refrigerant.
B.Excessive frost on the evaporator.
C.Excessive condenser cooling water.
D.Insufficient condenser cooling water flow.
第2题:
increase
reduce
maintain constant
None of the above is true
第3题:
Shortage of refrigerant oil
Slight shortage of refrigerant
Excessive condenser cooling water flow
Faulty expansion valve
第4题:
Latent heat of vaporization
Heat of compression
Superheat
All of the above
第5题:
too much cooling water going through the condenser
not enough refrigerant in the system
a leak in the evaporator coils
no enough cooling water going through the condenser
第6题:
purge the condenser if the waterside is dirty
check for proper water flow through the condenser
increase the high pressure cutout setting
reduce the cooling water flow
第7题:
insufficient cooling water flow to the condenser
a low refrigerant charge in the system
the liquid valve is open too much
high evaporator superheat
第8题:
too much superheat
insufficient superheat
suction pressure too low
excessive refrigerant returning to the compressor
第9题:
A shortage of liquid refrigerant
Excessive frost on the evaporator
Excessive condenser cooling water
Insufficient condenser cooling water flow
第10题:
increase the amount of cooling water to the condenser
decrease the amount of cooling water to the condenser
add more refrigerant to the system
remove some refrigerant from the system
第11题:
maintain adequate coil back pressure
prohibit flashing in the liquid line
reduce refrigerant volume in the system
reduce compressor discharge line loading
第12题:
excessive condenser cooling water
warm food in the refrigerator
a shortage of refrigerant
s shortage of compressor oil
第13题:
insufficient condenser cooling water
excessive condenser cooling water
air in the refrigeration system
excessive refrigerant in the system
第14题:
a shortage of compressor oil
warm food in the refrigerator
excessive condenser cooling water
a shortage of refrigerant
第15题:
restriction in refrigerant piping
air and non-condensable gases in the condenser
water in the refrigerant
flooding back of liquid refrigerant from the evaporator
第16题:
compressor;condenser
condenser;evaporator
throttle valve;evaporator
evaporator;condenser
第17题:
the compressor suction pressure is not too high
all air is purged from the pump and charging fittings
the high pressure cutout switch is held open to prevent accidental starting
the condenser is completely shutdown first
第18题:
change the expansion valve adjustment
readjust the water regulating valve to increase the flow of water
purge air from the condenser
clean the waterside of the condenser
第19题:
protect the compressor from liquid flood back
protect the compressor from low discharge pressure
start and stop the compressor upon system demand
start the compressor after a drop in the evaporator pressure
第20题:
box temperature solenoid valve will close
expansion valve will close
compressor will shutdown
king valve will open
第21题:
Condenser leakage
A shortage of liquid refrigerant
Excessive frost on the evaporator
Not enough condenser cooling water
第22题:
the compressor short cycling on high pressure cut out switch
high suction pressure
high head pressure
bubbles in the sight glass
第23题:
The condenser and the expansion valve
The king valve and the solenoid valve
The compressor and the expansion valve
The condenser and the solenoid valve