单选题Companycom is currently using a p690 and has just ordered a p5 590. They prefer to run in full system partition mode, since their application will utilize all the resources in the machine, and they don't want the overhead of an LPAR. What is the best r

题目
单选题
Companycom is currently using a p690 and has just ordered a p5 590. They prefer to run in full system partition mode, since their application will utilize all the resources in the machine, and they don't want the overhead of an LPAR. What is the best response to the customer about the POWER5 capabilities?()
A

POWER5 runs in an SMP mode as default

B

POWER5 can run in a full system mode the same as the p690

C

POWER5 can run in full system mode with the purchase of PLM

D

POWER5 can run in a full system mode, but it is in LPAR mode


相似考题

1. Companycom has a 16 way 1.65 GHz p5 590 and wants to install a i5/OS partition on their server. The customer wants to keep installation costs to a minimum by sharing devices between all LPARs. Before the operating system can be installed in this partition, the customer was told that there are certain limitations that must be observed. What are these limitations?()A、When the i5/OS partition is housed in the p5 590, the HMC allows seamless installation in a partition as long as the minimum one processor, 256 MB of memory, one Ethernet and one boot adapter/disk is available from internal hardware. B、V5R3 and later releases of i5/OS can be installed on a POWER5 server partition. Only one processor can be assigned to the i5/OS. A special expansion tower must be ordered. This expansion tower and its devices can be shared with other OS partitions. C、When the i5/OS partition is housed in the p5 590, the 5250 Twinaxial console must be used to set up the partition. Only one processor can be assigned to the i5/OS partition. A special expansion tower must be ordered to house the IOPs. Devices in the special expansion tower can be shared with other Linux partitions.  D、V5R3 and later releases of i5/OS can be installed on IBM eServer p5 servers. i5/OS can run on two processors in the p5 590. A special expansion tower must be ordered. This expansion tower and its devices cannot be shared with other OS partitions. The iSeries expansion towers are seen by the IBM eServer p5 server as an I/O subsystem.

更多“单选题Companycom is currently using a p690 and has just ordered a p5 590. They prefer to run in full system partition mode, since their application will utilize all the resources in the machine, and they don't want the overhead of an LPAR. What is the best r”相关问题
  • 第1题:

    After using the alt_disk_install command to clone a system image to another disk, the system administrator noticed a large number of defined devices not allocated to the LPAR. Which of the following is the most likely cause of this situation?()

    • A、The cfgmgr command was not run to reconfigure the devices
    • B、The machine was not booted into SMS MultiBoot mode after configuration
    • C、The machine was not in full system partition mode when the volume was created
    • D、The alt_disk_install command was not run with the -O option to remove references in the ODM

    正确答案:D

  • 第2题:

    Companycom has seven days of vmstat data on a p5 590. The server has a total of four test/dev LPARs and 4 production LPARs of one processor each. On the four test/dev LPARs, the data shows 90-95% peak utilizations with a duration of from 5 to 10 minutes. The average utilizations of all LPARs were between 15-30%. All of the applications have different times when they peak.  What is the best configuration to fully utilize the processor resource?()

    • A、Set up the server in SMP mode and use WLM to manage resources effectively
    • B、Set up eight dedicated LPARs and use DLPAR to manage resources effectively
    • C、Set up a shared pool with eight capped LPARs including production and test/dev
    • D、Set up a shared pool with eight uncapped LPARs with priority weight to Production

    正确答案:D

  • 第3题:

    A solution for two batch applications was proposed in Companycom meeting. They are currently running in two LPARs on a p690. On a daily basis, both applications use 15% of the machine for their workload, and increase to 100% when their weekly reports are run. Since the reports are not run on the same day, what is the best solution?()

    • A、COD
    • B、DLPAR
    • C、One big LPAR
    • D、Two separate p690 machines

    正确答案:B

  • 第4题:

    Companycom has just installed a p5 595 with four uncapped LPARs in a shared processor pool. The system and profile settings are still in their default states. One of the LPARs has an application that is consuming all of the available shared processor resources. Users of this application are complaining about response time. Which of the following changes to the slow LPAR would improve response time?()

    • A、Enable SMT
    • B、Reduce the weight
    • C、Renice the process
    • D、Increase the weight

    正确答案:D

  • 第5题:

    单选题
    Companycom purchased a new p5 570 without a HMC. The customer does not know how to power the full frame/system off since there does not appear to be an on/off button. What can be done to accomplish this task?()
    A

    Telnet into the machine and do a shutdown -Fr

    B

    Log into ASMI as Administrator and use ASMI menus

    C

    Log into the service processor using WebSM and use ASMI menus

    D

    Use the off button which is located to the left below the LEDs


    正确答案: B
    解析: 暂无解析

  • 第6题:

    单选题
    Companycom has seven days of vmstat data on a p5 590. The server has a total of four test/dev LPARs and 4 production LPARs of one processor each. On the four test/dev LPARs, the data shows 90-95% peak utilizations with a duration of from 5 to 10 minutes. The average utilizations of all LPARs were between 15-30%. All of the applications have different times when they peak.  What is the best configuration to fully utilize the processor resource?()
    A

    Set up the server in SMP mode and use WLM to manage resources effectively

    B

    Set up eight dedicated LPARs and use DLPAR to manage resources effectively

    C

    Set up a shared pool with eight capped LPARs including production and test/dev

    D

    Set up a shared pool with eight uncapped LPARs with priority weight to Production


    正确答案: A
    解析: 暂无解析

  • 第7题:

    单选题
    Companycom has a requirement for an LPAR in their p5 595 to run SUSE Linux. They also require an adapter that is not currently supported in Linux. Which of the following would be the best solution to recommend?()
    A

    Assign the adapter to an IO Hosting partition

    B

    Use AIX 5L affinity to move the application from SUSE to AIX

    C

    Use AIX 5.3 drivers to install the adapter in the Linux LPAR

    D

    Assign the adapter to an AIX 5.3 partition running Linux Affinity


    正确答案: A
    解析: 暂无解析

  • 第8题:

    单选题
    Companycom is currently using a p690 and has just ordered a p5 590. They prefer to run in full system partition mode, since their application will utilize all the resources in the machine, and they don't want the overhead of an LPAR. What is the best response to the customer about the POWER5 capabilities?()
    A

    POWER5 runs in an SMP mode as default

    B

    POWER5 can run in a full system mode the same as the p690

    C

    POWER5 can run in full system mode with the purchase of PLM

    D

    POWER5 can run in a full system mode, but it is in LPAR mode


    正确答案: A
    解析: 暂无解析

  • 第9题:

    单选题
    Company.com has a single pSeries server with two shared processor logical partitions. The first partition has peak resource requirements during weekdays. The second partition has peak resource requirements during weekends. During the peak times, the total workload between the partitions does NOT exceed the capacity of the server. However, the partitions are not able to utilize the full capacity of the system during peak times, because the necessary CPU and memory resources are not always allocated to the busiest partition. Which of the following options would best balance these resources?()
    A

    Configure AIX Workload Manager

    B

    Configure Partition Load Manager

    C

    Configure eServer Workload Manager

    D

    Use DLPAR from the HMC


    正确答案: B
    解析: 暂无解析

  • 第10题:

    单选题
    Companycom has just added some new disk drives to a p5 590. The customer needs to know the largest Logical Track Group that these drives will support. What is the best way to locate this information?()
    A

    Use lquerypv to read the drive

    B

    Use lspv and look at PP Size value

    C

    Look on the outside of the drive itself

    D

    Use bootinfo to find the LTG on the drive


    正确答案: B
    解析: 暂无解析

  • 第11题:

    单选题
    Companycom has just installed a p5 595 with four uncapped LPARs in a shared processor pool. The system and profile settings are still in their default states. One of the LPARs has an application that is consuming all of the available shared processor resources. Users of this application are complaining about response time. Which of the following changes to the slow LPAR would improve response time?()
    A

    Enable SMT

    B

    Reduce the weight

    C

    Renice the process

    D

    Increase the weight


    正确答案: B
    解析: 暂无解析

  • 第12题:

    单选题
    After using the alt_disk_install command to clone a system image to another disk, the system administrator noticed a large number of defined devices not allocated to the LPAR. Which of the following is the most likely cause of this situation?()
    A

    The cfgmgr command was not run to reconfigure the devices

    B

    The machine was not booted into SMS MultiBoot mode after configuration

    C

    The machine was not in full system partition mode when the volume was created

    D

    The alt_disk_install command was not run with the -O option to remove references in the ODM


    正确答案: C
    解析: 暂无解析

  • 第13题:

    Companycom has just added some new disk drives to a p5 590. The customer needs to know the largest Logical Track Group that these drives will support. What is the best way to locate this information?()

    • A、Use lquerypv to read the drive
    • B、Use lspv and look at PP Size value
    • C、Look on the outside of the drive itself
    • D、Use bootinfo to find the LTG on the drive

    正确答案:A

  • 第14题:

    Companycom is currently using a p690 and has just ordered a p5 590. They prefer to run in full system partition mode, since their application will utilize all the resources in the machine, and they don't want the overhead of an LPAR. What is the best response to the customer about the POWER5 capabilities?()

    • A、POWER5 runs in an SMP mode as default
    • B、POWER5 can run in a full system mode the same as the p690
    • C、POWER5 can run in full system mode with the purchase of PLM
    • D、POWER5 can run in a full system mode, but it is in LPAR mode

    正确答案:D

  • 第15题:

    Companycom has a p690 server with unused fiber (HBA) host bus adapters (feature code 6228) that they would like to reuse. They are interested in implementing Advanced Power Virtualization features particularly Virtual IO. What is the best way to proceed?()

    • A、Upgrade the p690 to a p5 590 server running AIX 5.3
    • B、Upgrade the p690 server to AIX 5.3 and implement Advanced Power Virtualization
    • C、Purchase a p5 590 with minimum resources and simply reuse the p690 unused fiber HBA adapters
    • D、Purchase a p5 590 that has all the needed resources and adapters for Advanced Power Virtualization

    正确答案:D

  • 第16题:

    Companycom has a requirement for an LPAR in their p5 595 to run SUSE Linux. They also require an adapter that is not currently supported in Linux. Which of the following would be the best solution to recommend?()

    • A、Assign the adapter to an IO Hosting partition
    • B、Use AIX 5L affinity to move the application from SUSE to AIX
    • C、Use AIX 5.3 drivers to install the adapter in the Linux LPAR
    • D、Assign the adapter to an AIX 5.3 partition running Linux Affinity

    正确答案:A

  • 第17题:

    单选题
    Companycom has a 16 way 1.65 GHz p5 590 and wants to install a i5/OS partition on their server. The customer wants to keep installation costs to a minimum by sharing devices between all LPARs. Before the operating system can be installed in this partition, the customer was told that there are certain limitations that must be observed. What are these limitations?()
    A

    When the i5/OS partition is housed in the p5 590, the HMC allows seamless installation in a partition as long as the minimum one processor, 256 MB of memory, one Ethernet and one boot adapter/disk is available from internal hardware. 

    B

    V5R3 and later releases of i5/OS can be installed on a POWER5 server partition. Only one processor can be assigned to the i5/OS. A special expansion tower must be ordered. This expansion tower and its devices can be shared with other OS partitions. 

    C

    When the i5/OS partition is housed in the p5 590, the 5250 Twinaxial console must be used to set up the partition. Only one processor can be assigned to the i5/OS partition. A special expansion tower must be ordered to house the IOPs. Devices in the special expansion tower can be shared with other Linux partitions.  

    D

    V5R3 and later releases of i5/OS can be installed on IBM eServer p5 servers. i5/OS can run on two processors in the p5 590. A special expansion tower must be ordered. This expansion tower and its devices cannot be shared with other OS partitions. The iSeries expansion towers are seen by the IBM eServer p5 server as an I/O subsystem.


    正确答案: A
    解析: 暂无解析

  • 第18题:

    单选题
    After using the alt_disk_install command to clone a system image to another disk, the system administrator noticed a large number of defined devices not allocated to the LPAR. Which of the following is the most likely cause of this situation?()
    A

    The cfgmgr command was not run to reconfigure the devices

    B

    The machine was not booted into SMS MultiBoot mode after configuration

    C

    The machine was not in full system partition mode when the volume was created

    D

    The alt_disk_install command was not run with the -O option to remove references in the ODM


    正确答案: C
    解析: 暂无解析

  • 第19题:

    单选题
    Companycom has a p690 server with unused fiber (HBA) host bus adapters (feature code 6228) that they would like to reuse. They are interested in implementing Advanced Power Virtualization features particularly Virtual IO. What is the best way to proceed?()
    A

    Upgrade the p690 to a p5 590 server running AIX 5.3

    B

    Upgrade the p690 server to AIX 5.3 and implement Advanced Power Virtualization

    C

    Purchase a p5 590 with minimum resources and simply reuse the p690 unused fiber HBA adapters

    D

    Purchase a p5 590 that has all the needed resources and adapters for Advanced Power Virtualization


    正确答案: D
    解析: 暂无解析

  • 第20题:

    单选题
    A solution for two batch applications was proposed in Companycom meeting. They are currently running in two LPARs on a p690. On a daily basis, both applications use 15% of the machine for their workload, and increase to 100% when their weekly reports are run. Since the reports are not run on the same day, what is the best solution?()
    A

    COD

    B

    DLPAR

    C

    One big LPAR

    D

    Two separate p690 machines


    正确答案: D
    解析: 暂无解析

  • 第21题:

    单选题
    A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()
    A

     Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.

    B

     Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.

    C

     Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.

    D

     Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.


    正确答案: D
    解析: 暂无解析

  • 第22题:

    单选题
    Companycom is currently using a p690 and has just ordered a p5 590. They prefer to run in full system partition mode, since their application will utilize all the resources in the machine, and they don't want the overhead of an LPAR. What is the best response to the customer about the POWER5 capabilities?()
    A

    POWER5 runs in an SMP mode as default

    B

    POWER5 can run in a full system mode the same as the p690

    C

    POWER5 can run in full system mode with the purchase of PLM

    D

    POWER5 can run in a full system mode, but it is in LPAR mode


    正确答案: C
    解析: 暂无解析

  • 第23题:

    单选题
    A client has an existing Logical Partition (LPAR) on a p650 running AIX 5.2 and will be porting this LPAR to a p5 590. A mksysb has been run to tape, and a compatible tape drive is available and allocated to the target LPAR on the p5 590. What additional resource needs to be available on the p5 590?()
    A

    A CD or DVD with installation media

    B

    An internal SCSI adapter in the target LPAR

    C

    An Ethernet adapter for access to an FTP server

    D

    Advanced Power Virtualization feature of the p5 590


    正确答案: B
    解析: 暂无解析

  • 第24题:

    单选题
    Companycom has just purchased a p5 570 with AIX 5.3. The customer would like to add a training LPAR to the system, but no processors are available. All of the partitions are using dedicated resources. The test LPAR is using one processor and has a 90% CPU idle rate. What can be done to setup this training LPAR quickly without disabling their current environment?()
    A

    Use AIX 5.3 which supports micro-partitioning for both the test and training LPARS

    B

    Use DLPAR to move resources from the test LPAR to training when training is active

    C

    Install Partition Load Manager to share resources between the test and training environments

    D

    Install Advanced Power Virtualization and then use micro-partitioning for both the test and  training LPARs


    正确答案: D
    解析: 暂无解析