第1题:
An administrator has removed a SATA hard drive from a failed server. Which of the following adapters would MOST likely be used by the administrator to transfer files from the drive to a laptop?()
第2题:
An administrator installs a new server with five 146GB drives and implements RAID 5 for hardware redundancy.How much disk space will be available for the OS, tools and regular files?()
第3题:
The administrator has just installed a new memory module into the server. Now, the server is not showing the new memory. Which of the following should the administrator perform FIRST?()
第4题:
An administrator will replace five current servers. Which of the following is the MOST important to review before installing new servers?()
第5题:
An administrator adds a new SATA hard drive into a functional server and attempts to boot the server. The server will no longer boot into the operating system. The administrator checks all the connections and reboots the server. The server still will not load the operating system. Which of the following is the MOST probable cause?()
第6题:
A server has 500GB of data that must be backed up nightly. The administrator has upgraded the oldLTO2 drive to an LTO3, but the data still will not fit on a single tape. Which of the following additional stepsshould the administrator perform to accommodate the data?()
第7题:
An administrator reboots a ten drive server, with a RAID 10 array, after a power failure and receives an error logical drive failed. Which of the following is the MOST likely cause?()
第8题:
Companycom has five LPARs, but only one CD drive. How should the CD drive be shared among all the users without system administrator action?()
第9题:
The BIOS is set with the wrong boot order.
The jumpers have not been set on the hard drive.
The hard drive is not compatible with the system board.
The boot.ini file needs to be modified.
第10题:
Check the backplane cabling.
Check the server BIOS.
Update the RAID controller firmware.
Install the latest hard drive firmware
第11题:
From the computer, install a local printer.
From the computer, install a network printer.
From the Active Directory domain, add the computer account for the Windows XP Professional computer to the Print Operators group.
From the Windows Server 2003 server, add the computer account for the Windows XP Professional computer to the Print Operators group.
第12题:
Restart the installation via WDS.
Shut down the server and check that all RAID drives are connected properly.
Restart the installation from CD and press F6 to install RAID drivers.
Go into the BIOS and set all RAID drives to compatibility mode.
第13题:
An administrator attempts to install the latest security patches for an older server. When the administrator runs the patch installer, the install fails. The administrator tries again, and the installer fails again. Which of the following is the MOST likely reason for this?()
第14题:
An administrator has added a new hard drive to a server that is running out of space on its C Drive and is experiencing slow performance. The administrator needs to free up space on the C Drive.Which of the following is the BEST action for the administrator to take to free up space on the drive?()
第15题:
An administrator has a rack server that is 5.25 inches (13.3 cm) tall, which of the following is the correct U size for this server?()
第16题:
The technician is working on a system and has determined that the hard drive must be reimaged. However, the customer wants to retain all the data. Which of the following would take the LEAST amount of time to implement?()
第17题:
An administrator has been instructed to add four additional drives to a server configured with RAID5. The server is using 146GB drives for the data. Without changing the configuration, how much additional data space would be available if the administrator purchased 300GB drives and added them to the existing array?()
第18题:
An administrator has a rack server that is 3.5 inches (8.9 cm) tall. Which of the following is the correct U size for this server?()
第19题:
An administrator is installing Windows Server 2003 via CD on a new server with an SAS RAID array.When the administrator reaches the option to select the target installation drive, there are no drives listed. Which of the following is the FIRST thing the administrator should do?()
第20题:
One
Three
Four
Five
第21题:
Replace the second drive with a hot swappable one.
Swap the drive boot order in the BIOS
Make the second disk active under the disk management tool.
Rebuild the array using the hardware RAID tool at boot.
第22题:
The jumpers are not set correctly on the drives.
The power supply is not rated high enough to support the additional drives.
The BIOS is not compatible with the drives.
The drives are not powered on.
第23题:
Verify uninterruptible power supply (UPS) load
Verify if server consumes 220V
Verify CPU load
Verify if server consumes 110V
第24题:
The hard drives were not plugged into the server correctly.
The controller driver is outdated and needs to be updated from the OEMs website.
The firmware for the server is too old and does not support the new RAID controller card.
The cable from the controller to the hard drive backplane is not connected.