A two-node cluster is attached via SAN to shared disk. The customer has requested that one of the nodes be moved to another room 300 feet away. However, this distance exceeds the length specified by the RS232 specifications. What solution would resolve the RS232 specification issue with the fewest additional components?()
第1题:
A customer synchronizes the cluster in a virtualized environment. During the process the following warning isdisplayed: "For nodes with a single Network Interface Card per logical network configured, it is recommended to includethe file ’/usr/es/sbin/cluster/netmon.cf’ with a pingable IP address as described in the PowerHA PlanningGuide". What should the customer do next?()
第2题:
A customer has a combination of fifteen Windows file servers with direct attached storage and three Power Systems with AIX database servers SAN attached to a DS4700. They would like to upgrade and plan for 40 TB capacity. The customer needs to move to a more scalable storage system to include all servers.Which of the following would be most appropriate to ask first?()
第3题:
A cluster administrator has been asked to install HACMP on two nodes with the following hardware: -two CPUs, - 1GB RAM, - one 1 36GB drive, -two 10/100/1000 Ethernet adapters, and -GB Fibre Channel adapters dual attached to SAN storage. In order to eliminate single points of failure,the administrator should first add which of the following:()
第4题:
A customer has Direct Attached Storage (DAS) storage for their Windows servers. They are allocating money in next year’s budget for additional storage. Which of the following questions should be asked first to determine the proper storage solution to propose?()
第5题:
An administrator has a two-node PowerHA cluster in a mutual takeover configuration. He needs to updatefrom 5.5 service pack 1 to 5.5 service pack 2. Which of the following actions will perform the updates with norisk of disruption to applications running in the cluster?()
第6题:
A customer has a combination of fifteen Windows file servers with direct attached storage and three Power Systems with AIX database servers SAN attached to a DS4700. They would like to upgrade and plan for 40 TB capacity. The customer needs to move to a more scalable storage system to include all servers. Which of the following would be most appropriate to ask first?()
第7题:
You are designing a Hyper-V solution. You plan to virtualize an application server. The application server requires failover clustering that uses shared storage. You need to choose the correct storage solution. What should you choose?()
第8题:
SAN switches
Fibre channel Hub(s)
IBM Storage Manager Agents
IBM Subsystem Device Driver
第9题:
A
B
C
D
第10题:
x3250
x3200
x3650
x3400
第11题:
A solution sizing questionnaire
Verify the customer has the proper racks
A Technical Delivery Assessment
Verify the customer has enough cooling in the computer room
第12题:
On one of the nodes,add the users via C-SPOC ’Add a User to the Cluster’smit menu.
Use C-SPOC to synchronize the password files between cluster nodes.
On all of the nodes,add the users to the /etc/passwd and system security files,and then synchronize the cluster.
On one of the nodes,add the users to the /tec/passwd and system security files,add home directories,and use cron to automate the movement of system security files between nodes.
第13题:
A customer has two single cluster IBM TS7700 Virtualization Engines at the same site. The customer wants to move one to a remote site and set up a grid configuration with the two clusters. The customer has fibre between the two sites. What is the most important factor to consider when planning the new configuration?()
第14题:
A customer has been working with your company to purchase an iDataPlex cluster. They have a configuration from IBM and are getting ready to place an order. Which should be done of the following?()
第15题:
The user base of a three-node cluster has increased. In order to add clustered users to all nodes, which of the following steps should be performed?()
第16题:
Company.com environment consists of 10 volume groups and 4 physical networks. The customer Desires the fastest possible fallover for a two-node cluster. Which of the following configuration alternatives will provide the fastest fallover?()
第17题:
An administrator has had a request from the data center for method to monitor the status of an HACMP cluster. The monitoring software environment currently used is not compatible with SNM at this time, and there is not time to crate a new tool. There is also a restriction that the data center personnel not be allowed to login to the HACMP cluster nodes. What method will provide the solution for customer?()
第18题:
A customer has a requirement for a storage solution that meets the following criteria: (1)Heterogeneous hosts attached (2)Support for block I/O (3)High Speed (4)Scalable Which solution would satisfy the customer’s requirement?()
第19题:
A pre-event
Error notification
Application monitoring
Custom verification methods
第20题:
an additional 1GB RAM to each node.
Another bootable mirrored disk drive.
A 10/100/1000 GB Ethernet adapter to be attached to a redundant switch.
Nothing,because this is a viable cluster solution with no single points of failure.
第21题:
A DS3000 iSCSI-based solution.
One MegaRAID 8480 card with 4 EXP3000 units.
An N3700 network attached solution.
A DS6000 Fibre Channel solution with EXP710 expansion units.
第22题:
Target mode fiber channel can be used with a SAN solution.
The heartbeat could be established by using a disk heartbeat.
An RS232 line driver can be used to extend the existing serial connection.
The NIM for the serial connection can be altered to compensate for the additional delay caused by the increased distance.
第23题:
IPAT via IP Aliasing,default shared volume groups
IPAT via IP Replacement default shared volume groups
IPAT via IP Aliasing,enhanced concurrent volume groups
IPAT via IP Replacement,enhanced concurrent volume groups