A VIO server has two fibre channel adapters, fcs0 fcs1, attached for redundant access to a storage subsystem. If fcs1 has failed, what is the correct procedure to rectify this problem? ()
第1题:
An administrator has a requirement to mirror the operating system on a VIO server. Which of the following IOS commands will achieve this?()
第2题:
Best practices would have no single point of failure between mirrored resources. In setting up virtual, internal boot disks for two client LPARs, how would this be accomplished?()
第3题:
Which action enables an administrator to make a VIO Server automatically activate when the physical machine is powered on?()
第4题:
Company.com recently experienced an unanticipated system outage when the VIO server was upgraded. The current p5-570 has six Micro-Partitions and a VIO server partition. How can a similar outage be avoided in the future?()
第5题:
A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()
第6题:
Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.
Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.
Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.
Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.
第7题:
mksysb -t vio /mountpoint
backupios -file /mountpoint
mksysb -i /mountpoint/vio.mksysb
backupios -mksysb -file /mountpoint/vio.mksysb
第8题:
Use smitty install on the client partitions.
Use padmin command in the VIO Server.
Use the oem_setup_env environment in the VIO Server.
Use cfgmgr to detect/configure the devices within the client AIX partition.
第9题:
A VIO server requires a dedicated LHEA port.
There is a limit of 32 LPARs per virtual LAN.
Two VIO servers will be required. A single VIO server can only provide virtual storage or Virtual Ethernet.
Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.
第10题:
Which of the following has an integrated database?()
第11题:
ompany.com has a Micro-Partitioned p5-570 4-way with six application partitions and two VIO servers. Each VIO server has been allocated 0.5 CPU and the application servers have been allocated 0.4 CPUs. The marketing department wants to deploy a new Web server to support the release of a product. The systems architect has recommended that the Web server will require a whole CPU. Which of the following should the technical specialist suggest to provide the most cost-effective deployment?()
第12题:
Company.com has a p5-570 with an application running on each of three Micro-Partitions. The disk I/O is shared through a VIO server. A technical specialist has been asked to upgrade the VIO server. Which of the following procedures should be taken to maintain the integrity of the partitions?()
第13题:
An administrator is trying to diagnose as to why a new VIO client (vio_client1) cannot see an allocated disk (hdisk4) from a VIO server (VIOS-A). The client virtual SCSI adapter has a slot ID of 5 and the corresponding VIO server virtual SCSI adapter has a slot ID of 3. The administrator checks the virtual SCSI configuration from the HMC using the following lshwres command. lshwres –r virtualio --rsubtype scsi -m 9117-570*65ABCDE --level lpar -F / lpar_name,slot_num,remote_lpar_name,remote_slot_num,backing_device VIOS A,5,vio_client2,2,hdisk3 VIOS-A,4,vio_client1,4,hdisk4 VIOS-A,3,vio_client1,6,hdisk5 VIOS-A,2,vio_client3,2,hdisk6 vio_client2,2,VIOS-A,5,hdisk0 vio_client1,4,VIOS-A,4,hdisk0 vio_client1,5,VIOS-A,3,null vio_client3,2,VIOS-A,2,hdisk0 From the output above, what is the most likely reason why the client cannot see the mapped storage?()
第14题:
A Power 720 customer using IVM wants to implement dual VIO servers, but is unable to create the second server. What is the most likely reason for this?()
第15题:
Design the solution and present it confidently so the customer does not question it.
Design the solution and ensure the customer understands the unknowns with the new technology.
Explain to the customer that the VIO Server does not benefit them when doing server consolidation so it has not been configured.
Explain to the customer that the details surrounding the VIO Server have not been clearly defined so designing a solution is premature.
第16题:
mirrorvg
iosmirror
mirrorios
mkiosmirror
第17题:
On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#
On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_name
On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi# On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_name
On the VIO Server: rmdev -dev rootvg_disk, rmlv rootlv_name On the AIX LPAR: rmdev -dl hdisk#, rmdev -dl vscsi#