Implement PowerHA SystemMirror on both VIO servers.
Configure Etherchannel between the client LPARs and the two VIO servers.
Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.
Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.
第1题:
What restrictions apply to using virtual Ethernet within a cluster containing VIO clients?()
第2题:
A proposed server architecture includes SAN LUNs being presented to client LPARs using shared HBAs to reduce infrastructure cost. The customer requires minimal management efforts for the dual VIO Servers. Which technology is recommended for this proposal?()
第3题:
A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()
第4题:
A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()
第5题:
A customer needs to create a number of LPARs on a new POWER6 server with some LPARs requiring a dedicated network and other LPARs utilizing Virtual Ethernet via a VIO server. Which limitation must be considered when planning the system configuration?()
第6题:
When configuring Shared Ethernet Adapter (SEA) failover between two VIO servers, which of the following attributes must have a different value on both VIO servers?()
第7题:
ImplementPowerHA SystemMirror on both VIO servers.
ConfigureEtherchannel between the client LPARs and the two VIO servers
Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.
Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.
第8题:
A VIO server requires a dedicated LHEA port.
There is a limit of 32 LPARs per virtual LAN.
Two VIO servers will be required. A single VIO server can only provide virtual storage or virtual Ethernet.
Two VIO servers will be required. One to provide virtual networking and another to provide dedicated networking.
第9题:
Implement PowerHA SystemMirror on both VIO servers.
Configure Etherchannel between the client LPARs and the two VIO servers
Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.
Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.
第10题:
HA Mode
Trunk priority
Control Channel
Default VLAN ID
第11题:
lspath
sdd query adapter
pcmpath query adapter
datapath query device
第12题:
When managing more than four VIO servers.
When installed with Power 570 and larger hardware.
When hosting both Linux and AIX on the same physical hardware.
When unexpected outage on a single HMC would prove an untenable risk for the hosted LPARs.
第13题:
LPAR1 is configured to have the same 2 LUNs virtualized by a redundant pair of VIO servers. Which command will validate that both storage paths are available?()
第14题:
Which of the following is a situation where dual (redundant) HMCs are recommended()?
第15题:
Which of the following can be used to re-deploy a system configuration in a disaster recovery scenario?()
第16题:
A system is being designed with many LPARs which will be clients of dual VIO Servers. The VIO Servers must be redundant so that, in the event of scheduled maintenance, the clients do not need to be shut down. Which of these strategies could be used to ensure that the client LPARs continue to be able to use the network in the event of a VIO Server being shut down?()
第17题:
A Power 720 customer using IVM wants to implement dual VIO servers, but is unable to create the second server. What is the most likely reason for this?()
第18题:
IPAT via Aliasing must be used
IPAT via Replacement must be used
Resilience must be provided by the use of dual VIO servers
Hardware Address Takeover (HWAT) must be used to ensure a consistent virtual MAC address
第19题:
Implement PowerHA SystemMirror on both VIO servers.
Configure Etherchannel between the client LPARs and the two VIO servers.
Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.
Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.
第20题:
ImplementPowerHA SystemMirror on both VIO servers.
ConfigureEtherchannel between the client LPARs and the two VIO servers
Configure Network Interface Backup between the two VIO servers and use each VIO server to access the network.
Implement Shared Ethernet Adapter failover and have all client partitions access the network through the shared adapters.
第21题:
NPIV
vSCSI
Arbitrated loop
Converged adapter
第22题:
Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAs
Move the existing physical network and storage adapters to the new system and virtualize the I/O using a single VIO Server.
Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC connectors and dual HBAs.
Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC connectors and the other with dual HBAs.
第23题:
Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.
Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.
Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.
Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.
第24题:
An HMC is required for dual VIO servers.
Dual VIO servers require a split backplane.
A dual VIO enablement code must be entered from the ASMI interface.
The second VIO server must be created using the IVM command line interface.