Replace the newly installed memory modules with another known-working unit.
Remove and reseat the memory, and recheck the memory reported.
Leave the configuration intact, and check cabling to ensure nothing was loose during the installation.
Perform a BIOS upgrade on the machine.
第1题:
The network technician is troubleshooting a network issue by implementing a new security device.After installing and configuring the device, which of the following steps should the technician takeNEXT?()
第2题:
A technician is performing a memory upgrade by installing an additional 1GB stick of DDR RAM into a system. When the installation is complete, the computer shows 2GB of RAM at POST; however, it now indicates a lower speed setting for the memory. Which of the following is the MOST likely cause?()
第3题:
A technician has to populate a server motherboard with memory. The board has a memory bus speed of 800 MHz. Which of the following memory types should be used?()
第4题:
A technician has just completed a CPU upgrade on a motherboard. Which of the following will MOST likely cause the PC not to boot?()
第5题:
A user is receiving an error about not having enough virtual memory. A technician wants to manually set the amount of available virtual memory for the computer. At a MINIMUM, the technician should set the virtual memory to be which of the following?()
第6题:
The newly installed RAM has a lower clock speed than the existing RAM.
The CPU is not configured to work with the additional RAM.
The system is incompatible with the new RAM.
The new RAM is of lower quality, and not dependable at higher speeds.
第7题:
Memory and virtual memory compatibility
Memory and speed compatibility
Memory and HDD compatibility
ESD standards were followed
第8题:
0.5 times the amount of physical memory
1.5 times the amount of physical memory
2 times the amount of physical memory
Equal to the amount of physical memory
第9题:
DDR3
SDRAM
DDR
DDR2
第10题:
RIMM
DDR RAM
SDRAM
SODIMM
第11题:
Verity full system functionality
Identify the main problem and question the user
Document their findings, actions, and outcomes
Escalate the issue to upper management
第12题:
MSCONFIG
DEBUG
EVENTVIEWER
REGEDIT
第13题:
A technician finished installing antivirus software. Which of the following should the technician perform NEXT?()
第14题:
An administrator is adding memory to a server. Once the system boots up, the same amount of memory appears as before the upgrade. Which of the following is the MOST likely cause?()
第15题:
A technician is installing new memory in a server. The technician would consult the HCL to ensure which of the following?()
第16题:
A technician is installing a memory upgrade for a remote user. The technician notes that the machine is not reporting the correct amount of memory that was installed during the POST step. Which of the following actions should the technician perform FIRST?()
第17题:
A user reports that they are unable to print to a remote printer. Which of the following should the technician check FIRST?()
第18题:
DDR2
DDR
SDRAM
DDR3
第19题:
Replace the newly installed memory modules with another known-working unit.
Remove and reseat the memory, and recheck the memory reported.
Leave the configuration intact, and check cabling to ensure nothing was loose during the installation.
Perform a BIOS upgrade on the machine.
第20题:
The technician used generic thermal paste.
The processor had pins broken during installation.
The memory is incompatible with the new CPU.
An incorrect fan size was installed on the heatsink.
第21题:
Run a full scan on the local disk.
Remove infected files.
Update antivirus signatures.
Quarantine infected files
第22题:
The memory is failing.
The CPU is overheating.
The hard drive is not attached properly.
The operating system is not installed.
第23题:
The memory is not the correct CAS latency.
The memory is not installed in the correct slot.
The memory does not have the correct timing.
The memory is not the correct speed.
第24题:
The memory is not the correct CAS latency.
The memory is not installed in the correct slot.
The memory does not have the correct timing.
The memory is not the correct speed.