The hard drives were not plugged into the server correctly.
The controller driver is outdated and needs to be updated from the OEMs website.
The firmware for the server is too old and does not support the new RAID controller card.
The cable from the controller to the hard drive backplane is not connected.
第1题:
An administrator has just upgraded a server from non-hot plug storage to all hot plug storage. The administrator powers up the server, during POST the RAID controller is recognized but none of the drive lights flash. Which of the following should the administrator do FIRST to troubleshoot the problem?()
第2题:
An administrator just installed a new RAID controller card into a server. The firmware is current for the controller card. When the server is powered up the administrator notices that the RAID controller card is not recognized during POST. Which of the following is the cause of the problem?()
第3题:
An administrator notes that after a recent power outage, some open files were corrupted on oneaffected file server. Which of the following items should the administrator consider to determine the cause of this corruption?()
第4题:
An administrator has just finished physically replacing the system board in a Windows domain controller. Which of the following must be done before booting the server back into Windows?()
第5题:
An administrator recently installed a new array controller into a server. When the server is running POST the controller does not appear as present. Which of the following could be the reason for this?()
第6题:
disk utilization
installation date
adapter baselines
location slot of the RAID controller
status of the adapter card installation
RAID controller information (warranty, specifications etc.)
第7题:
Update the time and date in the BIOS.
Update the firmware on the SCSI controller.
Update the firmware to the latest version.
Configure IPMI on the new board.
第8题:
292GB
438GB
584GB
728GB
第9题:
The power supply is not sufficient to power the server.
The voltage regulator module (VRM) was not installed.
The IRQ setting was not set.
The DMA setting was not set.
第10题:
Update the time and date in the BIOS.
Update the firmware on the SCSI controller.
Update the firmware to the latest version.
Configure IPMI on the new board.
第11题:
The hard drives were not plugged into the server correctly.
The controller driver is outdated and needs to be updated from the OEMs website.
The firmware for the server is too old and does not support the new RAID controller card.
The cable from the controller to the hard drive backplane is not connected.
第12题:
Check the backplane cabling.
Check the server BIOS.
Update the RAID controller firmware.
Install the latest hard drive firmware.
第13题:
An administrator notes that after a recent power outage, some open files were corrupted on one affected file server. Which of the following items should the administrator consider to determine the cause of this corruption?()
第14题:
Before installing a firmware update on a RAID controller which of the following should be done?()
第15题:
Which three should be documented after upgrading a SCSI RAID controller?()
第16题:
After installing a second processor and corresponding heatsink into a server, an administrator notices that the new processor is not showing up during POST. Which of the following could be the cause of this issue?()
第17题:
A technician installs a SATA controller card and moves the hard drive cable from the system board to the SATA controller. The system POSTs and the controller BIOS recognizes the hard drive but does not boot to the hard drive and start Windows. Which of the following is the MOST likely cause of the problem?()
第18题:
The servers memory
The servers RAID controller battery
The servers processor
The servers NIC teaming configuration
第19题:
The server BIOS firmware is out-of-date.
The server does not have the correct drivers.
The server hard drives have not begun to spin.
The server has too little memory installed.
第20题:
Check the backplane cabling.
Check the server BIOS.
Update the RAID controller firmware.
Install the latest hard drive firmware
第21题:
The server BIOS firmware is out-of-date.
The server does not have the correct drivers.
The server hard drives have not begun to spin.
The server has too little memory installed.
第22题:
The server's memory
The server's RAID controller battery
The server's processor
The server's NIC teaming configuration
第23题:
Windows cannot be booted from a controller card.
The hard drive must have Windows reinstalled because a new controller card was installed.
The SATA controller card was not set as a boot device in the computer BIOS.
The new controller must have the correct jumper settings for Windows mode.
第24题:
Move the RAID adapter to another slot.
Perform a baseline of the system.
Contact the reseller of the adapter for a replacement card.
Check the RAID adapter’s manufacturer for the latest drivers.