Use the 60 Amp line cords
Change the 100 Amp connector to a 60 Amp circuit
Submit an RPQ to order the p5 590 with 100 Amp power cords
Change the configuration and order the p5 590 with the 100 Amp power cords
第1题:
Companycom is considering a partitioned solution which will require cumulative rPerf total of 150. The original sizing came back recommending a 32-way p5 590. However, they have a requirement for future scalability and availability is important. Which of the following would be the best reason to recommend a p5 595?()
第2题:
Companycom is considering a large partitioned p5 590 to consolidate several smaller systems in their data center. Due to the complexity of the consolidation, the customer is asking the technical support specialist to give them a report which shows pre order PCI adapter placement and validates them against IBM's recommendations. The concern is that the factory will not install the adapters in the appropriate slots as the customer pre-selected. What IBM tool is available to provide this?()
第3题:
Companycom has a p690 server with unused fiber (HBA) host bus adapters (feature code 6228) that they would like to reuse. They are interested in implementing Advanced Power Virtualization features particularly Virtual IO. What is the best way to proceed?()
第4题:
Companycom is purchasing a 64-way p5 595. They have determined the location for the server is in a datacenter which does not have a raised floor. Which of the following would best meet the server requirements?()
第5题:
Companycom is purchasing a p5 590 which was configured with 60 Amp line cords. They have just indicated that their large datacenter is already wired for 100 Amp power circuits in the location where the server will be installed. What would be the recommended action?()
第6题:
During the Solution Assurance for a p5 590, Companycom states there is a plan to install OEM Emulex cards in the p5 590. The customer assumes there will be no problem with the plan since IBM resells the Emulex cards. What is the correct response for the customer?()
第7题:
A CD or DVD with installation media
An internal SCSI adapter in the target LPAR
An Ethernet adapter for access to an FTP server
Advanced Power Virtualization feature of the p5 590
第8题:
Enable DHCP server on the HMC
Configure host name and IP address on DNS server
Manually set the IP address of the service processor
Connect a RS-232 cable from the HMC to the service processor
第9题:
The Bulk Power Controllers are dependent upon the HMC to provide them with DHCP addresses.
A firewall is required to isolate the private network from any of the open networks to which the HMC is attached.
Network communications can be implemented through an open network. No private network is required but it is recommended.
All p5 590 and 595 servers are shipped with one service processor card. A private network is required to manage DHCP addresses.
第10题:
IBM System p5 570
IBM System p5 575
IBM System p5 590
IBM System p5 595
第11题:
The routes on the HMC
The firewall setting of the LAN adapter
The name resolution protocol on the p5 590 server
The subnet mask settings on the Ethernet adapters
第12题:
Add CPU and memory COD so they have room to grow if required
Make the server configuration twice as large as the current requirement
Configure the server for the current capacity requirements
Make the server configuration a little larger than the current capacity requirements
第13题:
Companycom has just added some new disk drives to a p5 590. The customer needs to know the largest Logical Track Group that these drives will support. What is the best way to locate this information?()
第14题:
A system administrator is installing a p5 590 server with an HMC. After pulling the websm client down, it is not possible to connect to the HMC. The HMC can be pinged from the client. Which of the following settings should be verified next?()
第15题:
A client has an existing Logical Partition (LPAR) on a p650 running AIX 5.2 and will be porting this LPAR to a p5 590. A mksysb has been run to tape, and a compatible tape drive is available and allocated to the target LPAR on the p5 590. What additional resource needs to be available on the p5 590?()
第16题:
Companycom wants the application server LPAR to communicate with the database LPAR on a p5 590 without using network adapters. What does the customer need to install?()
第17题:
A client tried to upgrade the system firmware on a p5 590, but it failed. What is the minimum requirement to update the system firmware from the HMC if inventory scout is already installed?()
第18题:
Which server houses the database partitions in the AIX BCU V2.1? ()
第19题:
The IBM CE will install the card
The card will not be supported by IBM
The AIX device driver should work fine
The customer is correct, there should be no problem
第20题:
New install of AIX
Migrate the 7040-61D
Utilize alt_disk_install
Use the enterprise back up strategy
第21题:
From the HMC
From a NFS mount
From a FTP server
From any CD or DVD drive on another server
第22题:
Two p5 570 16 way 1.9 MHz machines
One p5 590 32 way 1.65 MHz machines
One p5 595 32 way 1.65 MHz machines
Two p5 570 16 way 1.65 MHz machines
第23题:
An 8-port adapter to the HMC
A hub for the private network
An additional Ethernet card to the HMC
An additional Ethernet card for each partition
第24题:
A public internet connection
All of the Logical Partitions need to be active
One partition must be configured with Service Authority
A local Repository must be configured prior to the update