A banking customer plans to implement a BladeCenter H chassis. They plan for seven HS22 blades, six HX5 blades with MAX5, one 1U external Fibre Channel switch, and two 3U Fibre Channel storage devices with fourteen 146GB drives. Which of the following is 

题目

A banking customer plans to implement a BladeCenter H chassis. They plan for seven HS22 blades, six HX5 blades with MAX5, one 1U external Fibre Channel switch, and two 3U Fibre Channel storage devices with fourteen 146GB drives. Which of the following is the minimum amount of rack space required to implement the solution?()

  • A、32U 
  • B、25U 
  • C、22U 
  • D、21U

相似考题
更多“A banking customer plans to implement a BladeCenter H chassis. They plan for seven HS22 blades, six HX5 blades with MAX5, one 1U external Fibre Channel switch, and two 3U Fibre Channel storage devices with fourteen 146GB drives. Which of the following is ”相关问题
  • 第1题:

    A customer has provided the pSeries technical specialist with details of an HACMP solution that they would like validated.  The solution is for two POWER4+ p630 servers directly attached to a FAStT600 storage server as the shared storage.  Each system has the following: ? 2 integrated network ports ?   2 fibre channel adapter cards   ? 1 power supply and redundant cooling   ? HACMP v5.1   In addition to a second power supply, what further requirements, if any, are needed to validate this solution and ensure no single point of failure? ()

    • A、One fibre channel switch
    • B、Two fibre channel switches
    • C、Two Ethernet cards
    • D、Nothing

    正确答案:B

  • 第2题:

    Which of the following describes the advantage of using Fibre Channel over Ethernet (FCoE) in POWER6 and POWER7 Blades?()

    • A、The FCoE card provides both LAN and fibre channel function from a single card on the blade. 
    • B、The FCoE advanced technology removes the need for any BladeCenter switching to support this function.
    • C、Component reliability on the fibre channel over Ethernet is higher than on regular Ethernet and fibre channel adapters.
    • D、The AIX device driver for FCoE has been completely rewritten for the current adapter, eliminating errors and performance issues.

    正确答案:A

  • 第3题:

    A banking customer plans to implement a BladeCenter H chassis. They plan for seven HS22 blades, six HX5 blades with MAX5, one 1U external Fibre Channel switch, and two 3U Fibre Channel storage devices with fourteen 146GB drives. Which is the minimum amount of rack space required to implement the solution of the following?()

    • A、32U
    • B、21U
    • C、25U
    • D、22U

    正确答案:C

  • 第4题:

    A banking customer orders three IBM BladeCenter E chassis and thirty-four HS22 blades. Theustomer wants to fully populate the chassis with blades where possible. Which of the following is the minimum number of power cables required to provide redundancy? ()

    • A、12 
    • B、10 
    • C、8 
    • D、6

    正确答案:B

  • 第5题:

    A customer is ready to order a pSeries solution.  However, the pSeries technical specialist is unsure whether the customer preferred the fibre channel or the external SCSI disk attachment option.  What is the most appropriate action for the specialist to take next?()

    • A、Ask the customer to confirm which option is best for their environment.
    • B、Order the fibre channel option and purchase a converter later if necessary.
    • C、Order both SCSI and fibre channel adapters to cover both potential options.
    • D、Inform the customer that fibre channel was selected for performance reasons.

    正确答案:A

  • 第6题:

    A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch.Which of the following should be mentioned to the customer regarding the NPIV switch?()

    • A、You can not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch 
    • B、Using blade servers with the NPIV switch will require more fibre ports on the external fibre switch 
    • C、Storage devices like Fibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switch
    • D、The NPIV switch will count against the number of domains in a fabric

    正确答案:C

  • 第7题:

    A banking customer has the following requirements for an IBM BladeCenter solution with high speed fibre channel: (1)four 4-socket Microsoft SQL servers with two hot swap SAS drives  (2)two physical Microsoft Active Directory Servers  (3)twenty-two physical Citrix servers  (4)three physical Web servers (5)one physical vCenter server   (6)eight vSphere hosts  Which configuration minimally satisfies these requirements?()

    • A、Three IBMBladeCenter S chassis, three Brocade Fibre modules, six Ethernet modules
    • B、Three IBMBladeCenter E chassis, three Brocade Fibre modules, six Ethernet modules
    • C、Four IBMBladeCenter H chassis, four QLogic Fibre Channel modules, eight Ethernet modules
    • D、Three IBMBladeCenter H chassis, three QLogic Fibre Channel modules, six Ethernet modules

    正确答案:D

  • 第8题:

    A customer is deploying a new database on a PS701 Blade in a BladeCenter H, and requires redundant network and SAN adapters. Which configuration supports the customer requirement?()

    • A、Configure 2 CFFh combination fibre channel / gigabit Ethernet adapters
    • B、Configure 1 CFFh 2-port fibre channel adapter and 1 CIOv 2-port gigabit Ethernet adapter
    • C、Configure 1 CIOv 2-port fibre channel adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapter
    • D、Configure 1 CIOv 2-port gigabit Ethernet adapter and 1 CFFh combination fibre channel / gigabit Ethernet adapter

    正确答案:C

  • 第9题:

    单选题
    A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch.Which of the following should be mentioned to the customer regarding the NPIV switch?()
    A

    You can not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch 

    B

    Using blade servers with the NPIV switch will require more fibre ports on the external fibre switch 

    C

    Storage devices like Fibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switch

    D

    The NPIV switch will count against the number of domains in a fabric


    正确答案: C
    解析: 暂无解析

  • 第10题:

    单选题
    A customer has the following equipment installed in their data center:  (1)an IBM BladeCenter H chassis (2)two power supplies  (3)six HS22V blades (4)three Nortel 1/10 GB ESMs The retail customer purchased a new HX5 with MAX5.  Which of the following must be added to install the HX5 with MAX5?()
    A

    Two additional power supplies

    B

    Fibre Channel (FC) switches and SAN storage

    C

    A Nortel 1/10 GB ESM

    D

    SSD for the HX5


    正确答案: D
    解析: 暂无解析

  • 第11题:

    单选题
    A customer wants to implement the following Blades in BladeCenter H:Two POWER Blades running IBM i partitions.Two POWER Blades running AIX and LinuxFour x86 Blades running Windows. Which of the following design consideration statements is correct?()
    A

    The Blades must use the same CIOv and CFFh expansion adapter types.

    B

    Two physical BladeCenter H chassis will be required. One for the POWER Blades, the other for the x86  Blades.

    C

    The x86 Blades and POWER Blades may use different expansion adapters provided the POWER Blades  are in bays 1-7 and the x86 Blades are in slots 8-14.

    D

    The x86 Blades and POWER Blades may use different expansion adapters, provided the corresponding I/O modules to Blade midplane connections are configured in the Advanced Management Module (AMM).


    正确答案: A
    解析: 暂无解析

  • 第12题:

    单选题
    A Fibre Channel fabric (or Fibre Channel switched fabric, FC-SW) is a switched fabric of FibreChannel devices enabled by a Fibre Channel switch. Fabrics are normally subdivided by Fibre Channel zoning. Each fabric has a name server and provides other services. Higher redundancy over FC-AL,P2P.Which path selection protocol is used by Fibre Channel fabrics?()
    A

     OSPF

    B

     RIP

    C

     FSPF

    D

     VSANs


    正确答案: D
    解析: 暂无解析

  • 第13题:

    A customer wants to implement the following Blades in BladeCenter H:Two POWER Blades running IBM i partitions.Two POWER Blades running AIX and LinuxFour x86 Blades running Windows. Which of the following design consideration statements is correct?()

    • A、The Blades must use the same CIOv and CFFh expansion adapter types.
    • B、Two physical BladeCenter H chassis will be required. One for the POWER Blades, the other for the x86  Blades.
    • C、The x86 Blades and POWER Blades may use different expansion adapters provided the POWER Blades  are in bays 1-7 and the x86 Blades are in slots 8-14.
    • D、The x86 Blades and POWER Blades may use different expansion adapters, provided the corresponding I/O modules to Blade midplane connections are configured in the Advanced Management Module (AMM).

    正确答案:A

  • 第14题:

    A customer has a Fibre Channel switch residing in a configuration where both production and test data coexist. Which of the following is the simplest method for ensuring that the two types of data do not flow through the same port?()

    • A、VLAN
    • B、zoning
    • C、trunking
    • D、LUN masking

    正确答案:B

  • 第15题:

    A banking customer orders three IBM BladeCenter E chassis and thirty-four HS22 blades. The customer wants to fully populate the chassis with blades where possible. Which of the following is the minimum number of power cables required to provide redundancy?()

    • A、6
    • B、8
    • C、10
    • D、12

    正确答案:C

  • 第16题:

    A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch. Which of the following should be mentioned to the customer regarding the NPIV switch?()

    • A、Youcan not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch
    • B、Using blade servers with the NPIV switch will require morefibre ports on the external fibre switch
    • C、Storage devices likeFibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switch.
    • D、The NPIV switch will count against the number of domains in a fabric

    正确答案:C

  • 第17题:

    A customer is deploying a new database on a PS701 Blade in a BladeCenter H, and requires redundant network and SAN adapters. Which configuration supports the customer requirement?()

    • A、Configure 2CFFh combination fibre channel / gigabit Ethernet adapters
    • B、Configure 1CFFh 2-port fibre channel adapter and 1 CIOv 2-port gigabit Ethernet adapter
    • C、Configure 1CIOv 2-port fibre channel adapter and 1 CFFh combination fibre channel / gigabit Ethernet  adapter
    • D、Configure 1CIOv 2-port gigabit Ethernet adapter and 1 CFFh combination fibre channel / gigabit Ethernet  adapter

    正确答案:C

  • 第18题:

    A retail customer is looking at ways to reduce power requirements. They are considering deploying two hundred IBM HS22 blades running Red Hat Linux in the IBM BladeCenter E chassis. The customer has already chosen Intel L5640 CPUs to reduce power. Which on-board storage option allows the customer to reduce power consumption of each blade?()

    • A、One 50 GB SATA 1.8 inch SSD
    • B、Two 73GB 10K SAS HDD SFF
    • C、Two 31 GB SATA 2.5 inch SSD
    • D、Two 50GB SATA 1.8 inch SSD

    正确答案:C

  • 第19题:

    A customer has the following equipment installed in their data center:  (1)an IBM BladeCenter H chassis (2)two power supplies  (3)six HS22V blades (4)three Nortel 1/10 GB ESMs The retail customer purchased a new HX5 with MAX5.  Which of the following must be added to install the HX5 with MAX5?()

    • A、Two additional power supplies
    • B、Fibre Channel (FC) switches and SAN storage
    • C、A Nortel 1/10 GB ESM
    • D、SSD for the HX5

    正确答案:A

  • 第20题:

    A customer has a BladeCenter E installed and plans to migrate their current Blades to the BladeCenter H.  What options will migrate from the BladeCenter E to the BladeCenter H chassis? ()

    • A、SAN Switch modules
    • B、Blowers
    • C、Power supplies
    • D、Battery backup units

    正确答案:A

  • 第21题:

    单选题
    A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch. Which of the following should be mentioned to the customer regarding the NPIV switch?()
    A

    Youcan not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch

    B

    Using blade servers with the NPIV switch will require morefibre ports on the external fibre switch

    C

    Storage devices likeFibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switch.

    D

    The NPIV switch will count against the number of domains in a fabric


    正确答案: A
    解析: 暂无解析

  • 第22题:

    单选题
    Which of the following describes the advantage of using Fibre Channel over Ethernet (FCoE) in POWER6 and POWER7 Blades?()
    A

    The FCoE card provides both LAN and fibre channel function from a single card on the blade. 

    B

    The FCoE advanced technology removes the need for any BladeCenter switching to support this function.

    C

    Component reliability on the fibre channel over Ethernet is higher than on regular Ethernet and fibre channel adapters.

    D

    The AIX device driver for FCoE has been completely rewritten for the current adapter, eliminating errors and performance issues.


    正确答案: B
    解析: 暂无解析

  • 第23题:

    单选题
    A banking customer orders three IBM BladeCenter E chassis and thirty-four HS22 blades. Theustomer wants to fully populate the chassis with blades where possible. Which of the following is the minimum number of power cables required to provide redundancy? ()
    A

    12 

    B

    10 

    C

    8 

    D

    6


    正确答案: D
    解析: 暂无解析