Use ssh to connect to the HMC and reboot
The upgrade will display complete and ask you to reboot
Select shutdown in the Management section of the WebSM client
Once logged out of the WebSM client it will ask to logoff, shutdown or reboot. Select reboot.
第1题:
An administrator needs to recover an HMC due to a failed disk. The disk has been replaced, allowing the administrator to reinstall the HMC back to the required release of software. Backups of both the HMC Console Data and Upgrade Data are available. After reloading the HMC with the Recovery DVDs, what are the next steps to restore the HMC configuration?()
第2题:
Which one of these statements is true regarding hot pluggable PCIe and PCI-X slots in a Power 550?()
第3题:
Companycom currently has three p650 servers in their environment and they are implementing a p5 595. The p650 servers are running in an SMP environment, but are connected to a pair of HMCs. In order to follow best practices in the enterprise server environment and maintain HMC connectivity to the p650s, what else will needs to be ordered in addition to the p5 595?()
第4题:
Companycom purchased a p5 570 with no plans to partition. The customer plans to use the ASMI interface to power on and off the machine. How can ASMI be accessed without a HMC?()
第5题:
A system administrator wants to control the HMC from their workstation. Microsoft Windows 2000 is running and the HMC graphical user interface is being used remotely. Which of the following actions will accomplish this task?()
第6题:
A new p5 customer has just installed a partitioned p5-550 alongside some older POWER4 servers. The pSeries technical specialist has received a call to say that the existing HMC (7315) cannot connect to the new server. How can the specialist help the customer?()
第7题:
Include a new HMC in the order to connect to the p5 595
Include a pair of new HMCs in the order to connect to the p5 595
Include a media set for POWER5 HMC in the order to upgrade one of the existing HMC’s to POWER5 capabilities
Include a media set for POWER5 HMC in the order to upgrade both of the existing HMC to POWER5 capabilities Include a media set for POWER5 HMC in the order to upgrade both of the existing HMC? To POWER5 capabilities
第8题:
Both options back up user and partition profile data. Only the Backup Critical Console Data backs up TCP/IP settings or preferences
Both options back up partition profile information. Only the Backup Critical Console Data backs up service function settings, such as Inventory Scout, Service Agent, and Service Focal Point
The Backup Critical Console Data should be performed just before the HMC software update operation. The Save Upgrade Data should be performed each time configuration changes are made to the system or the HMC
The Save Upgrade Data should be performed just before the HMC software update operation. The Backup Critical Console Data should be performed each time configuration changes are made to the system or the HMC
第9题:
Explain to the customer that they need an additional HMC for the POWER5 system.
Obtain a PO from the customer to purchase additional serial connections to the HMC.
Obtain a PO from the customer to purchase additional Ethernet connections to the HMC.
Explain to the customer that they need a firmware update on the HMC to support both POWER4 and POWER5.
第10题:
Use the 'HMC Management > Restore HMC Data' option to first restore just the HMC Data..
Use the 'HMC Management > Restore Upgrade Data' option to first restore just the Upgrade Data.
Use the 'HMC Management > Restore HMC Data' option to first restore the HMC Data and then the Upgrade Data.
Use the 'HMC Management > Restore Upgrade Data' option to first restore the Upgrade Data, and then the HMC Data.
第11题:
Free up one HMC and update the software for use with the p5 570
Connect the new p5 570 server to an existing HMC and manage the p690s and p5 570 from that HMC
Order a new HMC to support the new p5 570 server since the CR3 HMC is not supported for a p5 570
Backup the HMC to DVD-RAM and select HMC migrate to move all the profile data to the new HMC software
第12题:
Use any Windows 2000 to graphically access the HMC
Load, install, and configure WebSM on the workstation
Telnet to the HMC using Exceed or a GUI emulator product from the workstation
Load, install, and configure OpenSSH or SSH on the workstation and access the HMC through the GUI interface
第13题:
Companycom has several CR3 HMCs managing their p690 servers. They have purchased a new p5 570 and would like to manage the new system with an existing HMC. What is required to support this environment?()
第14题:
A system administrator is installing a p5 590 server with an HMC. After pulling the websm client down, it is not possible to connect to the HMC. The HMC can be pinged from the client. Which of the following settings should be verified next?()
第15题:
A customer is buying 10 new Power 720 servers and will integrate them into their existing data center which also has two Power 595s and five Power 750s, taking the total number of systems to 17. All currently installed systems are managed by a single HMC.All the machines will have dual VIO Servers for redundancy, and 10 client LPARs. How can they manage the new machines for the least cost?()
第16题:
A base operating system has just been installed, successfully rebooted, and the user is now logged in as root. The user wants the server software bundle installed, but has additional software that must be installed with the bundle. Which of the following procedures should be performed to complete the installation?()
第17题:
The System Administrator wants to do a backup of the HMC and notices that there are two options on the HMC menu: Backup Critical Console data and Save Upgrade Data. Which of the following best describes the differences between the two options?()
第18题:
Run /usr/sbin/rsct/bin/rmcctrl z as hscroot.
Reboot the HMC, either through the GUI or via the command line.
Disable and re-enable RMC in the Firewall settings in the HMC GUI.
Select the Partition Communication checkbox in the LAN Adapter dialogue box.
第19题:
Cards can be added and then enabled via Hardware Management Console (HMC) GUI or command line.
The HMC allows access to the Advanced System Management Interface (ASMI), where the slots can be managed.
If the empty slot was already allocated to an LPAR, the LPAR can use the card after the cfgmgr script has been run.
The Hardware Management Console (HMC) GUI can guide a customer through the process of adding a card to an empty slot.
第20题:
Add the software to /usr/sys/inst.images
Update the bundle file in /usr/sys/inst.images
Install the bundle filelists and run update all
Add the software to the bundle file in /usr/sys/inst.data/sys_bundles
第21题:
The routes on the HMC
The firewall setting of the LAN adapter
The name resolution protocol on the p5 590 server
The subnet mask settings on the Ethernet adapters
第22题:
Use ssh to connect to the HMC and reboot
The upgrade will display complete and ask you to reboot
Select shutdown in the Management section of the WebSM client
Once logged out of the WebSM client it will ask to logoff, shutdown or reboot. Select reboot.
第23题:
Update the HMC software
Update the system firmware
Re-install the device driver
Flash update the two-port card
第24题:
By typing diags and then going to the ASMI menus
Through SSH from a TCP/IP connection on the server
Through WebSM which is connected to a system Ethernet port
By connecting through a web browser to an HMC Ethernet port