topsvcs,clstrmgr,clsmuxpd,grpsvcs,emsvcs,clinfo
topsvcs,grpsvcs,emsvcs,clstrmgr,clsmupxpd,clinfo
clstrmgr,clsmuxpd,clinfo,topsvcs,grpsvcs,emsvcs
clstrmgr,topsvcs,clxmuxpd,clinfo,grpsvcs,emsvcs
第1题:
During a cluster functionality test, and administrator performs a graceful stop for Node ’B’ in a three-node cluster. What is the expected state of the cluster after Node ’B’successfully completes?()
第2题:
A customer is in the process of testing their configuration prior to going live. The administrator discovers thatPowerHA is taking 31 seconds to deal with a standard NIC failure. What can the administrator do to speed upthe process of NIC failure detection and diagnosis?()
第3题:
An administrator has integrated a new application into an existing resource group. An application server withstart and stop scripts was defined and added to the resource group definition. The cluster was thensynchronized. How can the new application be started with minimal downtime?()
第4题:
During the installation of a cluster, the non-IP network failed. The cause was a connector that was Not properly secured. The customer wants a better notification method in the event that the non-IP network fails in the future. How could customization of the cluster be accomplished?()
第5题:
Which statement about using RMAN stored scripts is true?()
第6题:
AIX was shut down
A fatal corruption occurred in the gsclvmd daemon
The topsvcs daemon was stopped by the system resource controller
The grpsvcs process was stopped by the system resource controller
第7题:
The administrator must use Hardware Address Take over with HACMP.
The clsmuxpd process and the contents of the /etc/cluster/ping_client_list can address the issue.
HACMP does not have any facility to be compatible with older devices that have limited capabilities.
HACMP can use either hardware address take over,or clinfo can update the arp cache of the clients when an adapter event occurs.
第8题:
Customize the node up event script to send an email to the operator.
Have HACMP send mail when the non-IP network fails by customizing the RG_MMOVE event script.
Change the network module to be slower so that a temporary failure of the non-IP network would not report an error.
Use snmp or clinfo to monitor the status of the non-IP network and dispatch some type of warning message.
第9题:
/tmp/hacmp.out
/tmp/clstrmgr.debug
/usr/es/adm/cluster.log
/var/adm/hacmp/hacmp.out
第10题:
/tmp/hacmp.out
/tmp/clstrmgr.debug
/usr/es/adm/cluster.log
/var/hacrmp/clverify/clverify.log
第11题:
Nothing, the Recover From Script Failure will correct the issue.
Disable and re-enable the effected Ethernet adapter by using ifconfig.
Correct the error by setting the hostname on the effected node from the command line.
Verify that the clinfo daemon is running prior to executing the recover from scriptfailure.
第12题:
Tune the topsvcs NIM settings
Tune the grpsvcs NIM settings
Activate the fast failure detection (FFD) feature
Activate the Gigabit fast failover feature on the physical adapters
第13题:
During a planning session, Company.com expresses concern about the behavior of the nodes When HACMP is installed. Once department is reliant on an older piece of equipment that is critical to operations and must communicate to the database server. Previous network changes indicated that this piece of equipment does not support gratuitous ARP. How can HACMP best incorporate this restriction into the cluster design?()
第14题:
A cluster node has been started and has not acquired the resources in the resource groups. Which log file will show the details of any event script processing that has occurred?()
第15题:
When a problem occurs in an HACMP cluster,which log file will show the high level overview of the cluster operation?()
第16题:
To perform SNMP Monitoring of cluster, what daemon must be running?()
第17题:
An administrator was notified that a resource group has failed over from the home node, Node1 to a standbynode, Node2 and that Node1 had been powered off. Upon restarting Node1 the administrator checked the AIXerror log and the cluster.log Which of the following is most likely the cause of the failover?()
第18题:
To create and execute an RMAN stored script,you must use a recovery catalog.
When executing a stored script and a command fails,the remainder of the script is executed,and a message is written to the alert log file.
RMAN stored scripts can always be executed against any target database that is registered in the recovery catalog.
When you execute a stored script,it always executes using the persistent channel settings previously set with the CONFIGURE command.
第19题:
All cluster resources halt on Node ’B’,and one or both surviving nodes will gracefully acquire the resources.
All cluster processes halt on Node ’B’,the cluster resources remain active,and the remaining nodes take no action.
All cluster processes stay active on Node ’B’,cluster resources are halted,and the remaining nodes take no action.
All cluster resources will stop,cluster processes halt on Node ’B’,and the remaining cluster nodes take no action.
第20题:
clstat
clinfo
cldiag
clverify
第21题:
Each process has its own protected memory space
Each process is started manually by the user at boot
All processes are dependent on each other
Multiple processes allow each routing protocol to be independent
第22题:
The administrator will need to perform an rg_move operation
The administrator will need to un-manage and re-manage the resource group
The administrator will need to execute the new start script from the command line
The new start script will be executed as part of the DARE operation to synchronize the cluster
第23题:
/usr/sbin/rsct/bin/hagsd
/usr/sbin/rsct/bin/clinfo
/usr/sbin/rsct/bin/clsmuxpd
/usr/sbin/rsct/bin/clssnmpstatd