What kind of cable should be used to establish a trunked line between two Catalyst switches?
A.A straight-through cable
B.An EIA/TIA-232 serial cable
C.An auxiliary cable
D.A modem cable
E.A cross-over cable
第1题:
There is a connectivity problem between the serial 0/0 interface of router TESTKING1 and the serial 0/0 interface of TESTKING2. A leased line point to point circuit is installed between these two routers. The output from the "show interface serial 0/0" command is displayed below for each of these routers:From your observations of the above exhibit, what is the underlying cause of the problem?()
A. The loopback is not set.
B. The serial cable is faulty.
C. The subnet mask is not configured properly.
D. The IP address is not configured properly.
E. The Layer 2 frame types are not compatible.
F. The keepalive setting is not configured properly.
第2题:
A. Set each end of the trunk line to IEEE 802.1Q encapsulation.
B. Set the same VTP management domain name on both switches.
C. Set all ports on the two switched as access ports.
D. Configure one of the two switches as a VTP server.
E. Connect the two switches using a rollover cable.
F. Use a router to forward VTP traffic between the VLANs.
第3题:
Workstation A has been assigned an IP address of 192.0.2.24/28. Workstation B has been assigned an IP address of 192.0.2.100/28. The two workstations are connected with a straight-through cable. Attempts to ping between the hosts are unsuccessful. What two things can be done to allow communications between the hosts? ()
A. Replace the straight-through cable with a crossover cable.
B. Change the subnet mask of the hosts to /25.
C. Change the subnet mask of the hosts to /26.
D. Change the address of Workstation A to 192.0.2.15.
E. Change the address of Workstation B to 192.0.2.111.
第4题:
Workstation A has been assigned an IP address of 192.0.2.24/28. Workstation B has beenassigned an IP address of 192.0.2.100/28. The two workstations are connected with a straight-through cablE.Attempts to ping between the hosts are unsuccessful. What two things can be done to allow communications between the hosts? ()
A.Replace the straight-through cable with a crossover cable
B.Change the subnet mask of the hosts to /25
C.Change the subnet mask of the hosts to /26
D.Change the address of Workstation A to 192.0.2.15
E.Change the address of Workstation B to 192.0.2.111
第5题:
For which type of connection should a straight-through cable be used?()
第6题:
Company.com wishes to use HACMP on two IBM eServer pSeries servers. During the planning session, it was decided to use the native serial ports s1 or s2 for a non-IP heartbeat network. What should be done to ensure the serial network will function with HACMP heartbeats?()
第7题:
What kind of cable should be used to establish a trunked line between two Catalyst 2950 switches?()
第8题:
An administrator is having a hard time adding a new switch to the network. After verifying that allthe ports are configured correctly on each switch, which of the following should the administratorverily NEXT?()
第9题:
When making a serial connection between two Windows 2000 machines, which type of cable is needed for proper communications?()
第10题:
Use either s1 or s2 port configured as a TTY interface with a NULL Modem cable.
Use the s2 serial port on each system configured as a TTY interface with a NULL modem cable.
Use the s1 port on each system configured as a TTY interface with a standard serial modemcable.
Verify with IBM support which native serial ports for the server model can be used for HACM pheartbeats.
第11题:
CAT3 cable
Serial cable
Crossover cable
Rollover cable
第12题:
show interfaces serial 0/0
show running-config
show version
show controllers serial 0/0
show ip interface
show line serial 0/0
第13题:
A. a straight-through cable
B. an EIA/TIA-232 serial cable
C. an auxiliary cable
D. a modem cable
E. a cross-over cable
第14题:
A. Each end of the trunk line must be set to IEEE 802.1E encapsulation.
B. The VTP management domain name of both switches must be set the same.
C. All ports on both the switches must be set as access ports.
D. One of the two switches must be configured as a VTP server.
E. A rollover cable is required to connect the two switches together.
F. A router must be used to forward VTP traffic between VLANs.
第15题:
A.switch to switch
B.switch to hub
C.switch to router
D.hub to hub
E.router to PC
第16题:
Which command can be used to determine the type of cable attached to the Serial 0/0 interface on a router?()
第17题:
What must an administrator do in order to successfully configure a VLAN trunk between two switches?()
第18题:
Which type of cable should be used to make a connection between the Fa0/0 port on a router and the Fa0/0 port switch?()
第19题:
A network administrator needs to add an additional connection to a room. The administrator adds a new Ethernet switch and must connect it to an existing switch. Which cable type should be used to connect the two switches?()
第20题:
Which of the following should be used to check a serial port for functionality?()
第21题:
switch to switch
switch to hub
switch to router
hub to hub
router to PC
第22题:
Rollover cable
Console cab le
Crossover cable
Straight-through cable
Serial cable
第23题:
a straight-through cable
an EIA/TIA-232 serial cable
an auxiliary cable
a modem cable
a cross-over cable