The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to______.
A.precipitate(使沉淀) silica (硅石)from solution
B.reduce corrosion in the heating coil
C.prevent clogging and erosion in the coil
D.maintain zero water hardness
第1题:
If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.
A.high steam pressure in the boiler
B.abnormally high feed-water temperature
C.abnormally high boiler water temperature
D.steam demand exceeding feed pump capacity
第2题:
will be modulated in proportion
will be modulated in proportion and integral
will be modulated in proportion and differential
will not be modulated at all
第3题:
The safety valve escape piping should be disconnected from the valve body and a blank inserted
The boiler vent valves should be opened
All hand-hole/manhole covers should be tightened up as much as possible to preclude any leaks
All of the above
第4题:
The safety valve escape piping should be disconnected from the valve body and a blank inserted
The boiler vent valves should be opened
All handhole/manhole covers should be tightened up as much as possible to preclude any leaks
All of the above
第5题:
when the boiler has been secured long enough for most solids to settle
when the boiler has been cooled to ambient temperature
only after raising the water level to within 0~5 inch of the high water cutout only
after bypassing the low pressure
第6题:
firing for extended periods in the low fire mode
overheating, due to waterside deposits
varying the water level above the crown sheet
carrying excessive alkalinity in the boiler water
第7题:
soap hardness
nitrog encontent
chloride content
dissolved CO2
第8题:
total dissolved solids
salt contamination
water hardness
chlorine contamination
第9题:
completely drain the boiler in an emergency
prevent sludge from forming in the drum
remove floating impurities from the boiler water surface
remove settled solids from the water drum
第10题:
check and regulate the water level
close the air cock once fires are lit
blowdown the gage glass
crack the steam stop to assure protective steam flow
第11题:
hour
day
week
month
第12题:
Clean all electrical connections
Lift the relief valves by hand
Inspect and clean all solenoid valves
Inspect for oil and water leaks
第13题:
concentrations of calcium sulfate in the boiler water
fuel oil in the feed water
improper treatment of the feed water with calcium sulfate
excessive feed water alkalinity
第14题:
relieve excess fuel oil pressure during the “off” fire cycle
admit water to the dry pipe
throttle the forced draft fan output for proper combustion
reduce excess steam pressure in the boiler
第15题:
operating the boiler at less than normal water level
installing fins on the firesides of water-tubes
increasing the amount of excess air to the burners
treating the boiler water with chemical oxygen scavengers
第16题:
steam stop valve
dry pipe
feedwater system
generating tubes
第17题:
remove suspended and precipitated solids from the boiler water
completely drain the boiler in an emergency situation
prevent hardened scale deposits in the water drum
remove floating impurities from the oily water surface
第18题:
dissolved oxygen
chlorides
sludge
dissolved nitrogen
第19题:
precipitate silica from solution
reduce corrosion in the heating coil
prevent clogging and erosion in the coil
maintain zero water hardness
第20题:
caustic embrittlement of the boiler metal
acidic corrosion of the boiler metal
hard scale deposits on the boiler tubes
etching of the heat exchange surfaces
第21题:
high steam pressure in the boiler
abnormally high feed water temperature
abnormally high boiler water temperature
steam demand exceeding feed pump capacity
第22题:
10
7
4
1
第23题:
bottom blow the boiler
treat the water with caustic soda
treat the water with chemical scavengers
reduce the water alkalinity to recommended readings