The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to______.

A.precipitate(使沉淀) silica (硅石)from solution

B.reduce corrosion in the heating coil

C.prevent clogging and erosion in the coil

D.maintain zero water hardness


相似考题
参考答案和解析
正确答案:B
更多“The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH ”相关问题
  • 第1题:

    If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause may be ______.

    A.high steam pressure in the boiler

    B.abnormally high feed-water temperature

    C.abnormally high boiler water temperature

    D.steam demand exceeding feed pump capacity


    正确答案:B

  • 第2题:

    单选题
    The water level of an exhaust gas boiler which is independent of the auxiliary boiler and just as the extra heating surface of it ()
    A

    will be modulated in proportion

    B

    will be modulated in proportion and integral

    C

    will be modulated in proportion and differential

    D

    will not be modulated at all


    正确答案: C
    解析: 暂无解析

  • 第3题:

    单选题
    In readying an auxiliary water-tube boiler for a routine hydrostatic test, which of the following procedures should be undertaken prior to filling the boiler with fresh water?()
    A

    The safety valve escape piping should be disconnected from the valve body and a blank inserted

    B

    The boiler vent valves should be opened

    C

    All hand-hole/manhole covers should be tightened up as much as possible to preclude any leaks

    D

    All of the above


    正确答案: D
    解析: 暂无解析

  • 第4题:

    单选题
    In readying an auxiliary water-tube boiler for a routine hydrostatic test, which of the following procedures should be undertaken prior to filling the boiler with fresh water?()
    A

    The safety valve escape piping should be disconnected from the valve body and a blank inserted

    B

    The boiler vent valves should be opened

    C

    All handhole/manhole covers should be tightened up as much as possible to preclude any leaks

    D

    All of the above


    正确答案: B
    解析: 暂无解析

  • 第5题:

    单选题
    The correct procedure for giving an auxiliary boiler a bottom blow, is to begin()
    A

    when the boiler has been secured long enough for most solids to settle

    B

    when the boiler has been cooled to ambient temperature

    C

    only after raising the water level to within 0~5 inch of the high water cutout only

    D

    after bypassing the low pressure


    正确答案: A
    解析: 暂无解析

  • 第6题:

    单选题
    A distorted furnace in a fire-tube auxiliary boiler may be the result of ()
    A

    firing for extended periods in the low fire mode

    B

    overheating, due to waterside deposits

    C

    varying the water level above the crown sheet

    D

    carrying excessive alkalinity in the boiler water


    正确答案: C
    解析: 暂无解析

  • 第7题:

    单选题
    The water in an auxiliary boiler should be chemically tested daily for alkalinity and()
    A

    soap hardness

    B

    nitrog encontent

    C

    chloride content

    D

    dissolved CO2


    正确答案: B
    解析: 暂无解析

  • 第8题:

    单选题
    The water in an auxiliary boiler should be tested for chloride content to determine ().
    A

    total dissolved solids

    B

    salt contamination

    C

    water hardness

    D

    chlorine contamination


    正确答案: B
    解析: 暂无解析

  • 第9题:

    单选题
    Bottom blow valves are installed on auxiliary water-tube boilers to ()
    A

    completely drain the boiler in an emergency

    B

    prevent sludge from forming in the drum

    C

    remove floating impurities from the boiler water surface

    D

    remove settled solids from the water drum


    正确答案: B
    解析: 暂无解析

  • 第10题:

    单选题
    Prior to lighting off a cold automatically fired auxiliary boiler, you should ().
    A

    check and regulate the water level

    B

    close the air cock once fires are lit

    C

    blowdown the gage glass

    D

    crack the steam stop to assure protective steam flow


    正确答案: A
    解析: 暂无解析

  • 第11题:

    单选题
    The water in an operating auxiliary boiler should be tested for alkalinity and chloride content each().
    A

    hour

    B

    day

    C

    week

    D

    month


    正确答案: A
    解析: 暂无解析

  • 第12题:

    单选题
    Which action should be taken when an auxiliary boiler in is operation?()
    A

    Clean all electrical connections

    B

    Lift the relief valves by hand

    C

    Inspect and clean all solenoid valves

    D

    Inspect for oil and water leaks


    正确答案: B
    解析: 暂无解析

  • 第13题:

    单选题
    The most common cause of scale formation in an auxiliary boiler is ()
    A

    concentrations of calcium sulfate in the boiler water

    B

    fuel oil in the feed water

    C

    improper treatment of the feed water with calcium sulfate

    D

    excessive feed water alkalinity


    正确答案: C
    解析: 暂无解析

  • 第14题:

    单选题
    The purpose of the safety relief valves installed on an auxiliary boiler is to ().
    A

    relieve excess fuel oil pressure during the “off” fire cycle

    B

    admit water to the dry pipe

    C

    throttle the forced draft fan output for proper combustion

    D

    reduce excess steam pressure in the boiler


    正确答案: C
    解析: 暂无解析

  • 第15题:

    单选题
    The rate of heat transfer in a water-tube auxiliary boiler can be increased by ().
    A

    operating the boiler at less than normal water level

    B

    installing fins on the firesides of water-tubes

    C

    increasing the amount of excess air to the burners

    D

    treating the boiler water with chemical oxygen scavengers


    正确答案: B
    解析: 暂无解析

  • 第16题:

    单选题
    In an auxiliary boiler steam and water system, the highest pressure will be in the ().
    A

    steam stop valve

    B

    dry pipe

    C

    feedwater system

    D

    generating tubes


    正确答案: B
    解析: 暂无解析

  • 第17题:

    单选题
    Bottom blow valves are installed on auxiliary water-tube boilers to ()
    A

    remove suspended and precipitated solids from the boiler water

    B

    completely drain the boiler in an emergency situation

    C

    prevent hardened scale deposits in the water drum

    D

    remove floating impurities from the oily water surface


    正确答案: B
    解析: 暂无解析

  • 第18题:

    单选题
    The water in an auxiliary boiler should be tested daily for ().
    A

    dissolved oxygen

    B

    chlorides

    C

    sludge

    D

    dissolved nitrogen


    正确答案: C
    解析: 暂无解析

  • 第19题:

    单选题
    The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to()
    A

    precipitate silica from solution

    B

    reduce corrosion in the heating coil

    C

    prevent clogging and erosion in the coil

    D

    maintain zero water hardness


    正确答案: C
    解析: 暂无解析

  • 第20题:

    单选题
    Excessive alkalinity of the water in an auxiliary boiler can cause ().
    A

    caustic embrittlement of the boiler metal

    B

    acidic corrosion of the boiler metal

    C

    hard scale deposits on the boiler tubes

    D

    etching of the heat exchange surfaces


    正确答案: A
    解析: 暂无解析

  • 第21题:

    单选题
    If the feed pump for an auxiliary boiler fails to deliver the feed water to the boiler, the cause maybe ().
    A

    high steam pressure in the boiler

    B

    abnormally high feed water temperature

    C

    abnormally high boiler water temperature

    D

    steam demand exceeding feed pump capacity


    正确答案: C
    解析: 暂无解析

  • 第22题:

    单选题
    Before an auxiliary boiler is shutdown for an extended period of time, the water in the boiler should have a pH value of ().
    A

    10

    B

    7

    C

    4

    D

    1


    正确答案: D
    解析: 暂无解析

  • 第23题:

    单选题
    If an operating auxiliary boiler has a water pH reading of 7, you should ().
    A

    bottom blow the boiler

    B

    treat the water with caustic soda

    C

    treat the water with chemical scavengers

    D

    reduce the water alkalinity to recommended readings


    正确答案: C
    解析: 暂无解析