When an auxiliary boiler is panting and emitting(发出) black smoke, you should______.
A.increase the fuel oil temperature
B.decrease the fuel oil temperature
C.decrease the fuel oil supply pressure
D.increase the air supply
第1题:
cold fuel oil
low fuel oil pressure
low atomizing steam pressure
water in the fuel oil
第2题:
low water level
high water level
excessively high fuel pressure
low oil temperature
第3题:
increase the fuel oil temperature
decrease the fuel oil temperature
decrease the fuel oil supply pressure
increase the air supply
第4题:
dissolved oxygen
chlorides
sludge
dissolved nitrogen
第5题:
steam demand is high
salinity is high
safety valve simmers
burner flame is extinguished
第6题:
space limitations prevent separately run pipes
the engines are small auxiliary units
they are arranged to prevent gas backflow to each engine
a waste heat boiler is installed
第7题:
defective solenoid valve
dirty fuel nozzle
grounded high tension lead
faulty ignition cable connector
第8题:
precipitate silica from solution
reduce corrosion in the heating coil
prevent clogging and erosion in the coil
maintain zero water hardness
第9题:
low water level
low oil pressure
excessively high fuel pressure
an improper air/fuel ratio
第10题:
high steam pressure in the boiler
abnormally high feed water temperature
abnormally high boiler water temperature
steam demand exceeding feed pump capacity
第11题:
10
7
4
1
第12题:
Clean all electrical connections
Lift the relief valves by hand
Inspect and clean all solenoid valves
Inspect for oil and water leaks
第13题:
To indicate the location of the auxiliary-instance online redo logs.
To indicate the location of the target database datafiles.
To indicate the location of the auxiliary-instance control file and online redo logs.
To indicate the location of the auxiliary-instance database datafiles.
This is not a valid parameter when duplicating a database.
第14题:
relight the boiler immediately to prevent loss of steam pressure
relight the fire off the brickwork as the bricks are cherry red
purge the furnace of any combustible gases before attempting to relight the fire
speed up the feed pump to prevent dry firing when the burner flame is reestablished
第15题:
engine overload
low combustion temperature
plugged fuel nozzle holes
excessive compression pressure
第16题:
salinity is abnormally high
steam demand is too high
water level is abnormally low
feedwater flow is low
第17题:
air supply is shut off
fuel supply is shut off
water supply is shut off
safety valve lifts
第18题:
monkey
donkey
waste heat
main
第19题:
rise when the steam pressure is increased
remain constant as long as the feed pump operates
fall when the steam pressure is decreased
vary as the steam demand changes
第20题:
caustic embrittlement of the boiler metal
acidic corrosion of the boiler metal
hard scale deposits on the boiler tubes
etching of the heat exchange surfaces
第21题:
check the air filter for obstruction
check for an exhaust leak
check the exhaust temperature
secure the engine
第22题:
check and regulate the water level
close the air cock once fires are lit
blowdown the gage glass
crack the steam stop to assure protective steam flow
第23题:
bottom blow the boiler
treat the water with caustic soda
treat the water with chemical scavengers
reduce the water alkalinity to recommended readings