Prolonged operation of a diesel engine with a closed cooling water system, at lower than normal designed operating temperatures can ______.
A.increase power output
B.decrease lube oil viscosity
C.eliminate fuel knock
D.cause sulfuric acid formation
第1题:
a broken shaft on the freshwater pump
an excessive accumulation of scale exchanger
an incorrect thermostatic element operating range
lube oil in the cooling water
第2题:
Baffle plates that have been bent during prior removal
Leaks in the cooler tube nest
Operating the engine while maintaining a high sea water outlet temperature
A punctured sea water strainer supplying cooling water to the heat exchanger
第3题:
air binding of the engine cooling system
a cracked water cooled exhaust manifold
blockage in the heat exchanger
faulty operation of the thermostat
第4题:
air in the cooling system
an overhauled water pump
correct amount of coolant
no air in the cooling system
第5题:
reduce water temperature
reduce water turbulence
provide an air cushion
allow for an increase in water volume as the engine warms up
第6题:
raw water pump discharge
expansion tank outlet
cooling water heat exchanger
outlet engine jacket water outlet
第7题:
loss of suction in the circulating pump
leak in the primary cooling system
broken raw water pump shaft
burned or cracked piston in one cylinder
第8题:
suction pressure regulator
thermostatic bypass valve
sea water temperature
water level in the expansion tank
第9题:
slight acidity
slight alkalinity
excessive alkalinity
excessive acidity
第10题:
jacket water outlet
cooling water pump outlet
heat exchanger outlet
expansion tank atmospheric vent
第11题:
a setting tank
a service tank
a head tank
an expansion joint
第12题:
regulating the level of corrosion inhibitor in the primary cooling system
the level of the freshwater expansion tank
varying the engine load to meet temperature requirements
the operation of the thermostatic valve
第13题:
lube cooler failure
poor heat transfer
mechanical lubricator failure
camshaft seizure
第14题:
fresh water expansion tank
sea water expansion tank
thermostatic expansion valve
jacket water cooler accumulator
第15题:
the proper back pressure
the cooling water temperature
correct timing and proper seating
accurate metering and the exhaust temperature
第16题:
improper venting of the cooling system
carrying the expansion tank water level too high
a totally clogged impeller in the cooling water pump
an incorrectly set cooling system temperature control
第17题:
jacket water outlet
expansion tank inlet
heat exchanger inlet
cooling water pump outlet
第18题:
sea water temperature must never be warmer than 40℃
jacket water pressure should always be greater than the sea water pressure
jacket water temperature must always be less than 60℃
jacket water pressure must always be less than the sea water pressure
第19题:
Defective temperature controls in the system
Cavitation in the cooling water pump
Opened vent in the cooling system
Restricted water passages in the engine
第20题:
cooling water pump
nozzle cooling passages
cylinder jackets
heat exchanger
第21题:
the formation of sulfuric acid
a decrease in lube oil viscosity
a decrease in cooling water pH
a thermostat failure
第22题:
slightly acidic condition
slightly alkaline condition
overtreatment of water
neutral condition of water
第23题:
cooling water of the cooling system
fuel of the FO system
LO of the LO system
cooling water of the cooling system and LO of the LO system