The ventilation system of your ship has fire dampers restrained by fusible links. Which statement is TRUE?
A.Fusible links must be replaced if a damper is activated
B.Fusible links are tested by applying a source of heat to them
C.Fusible links must be replaced at every inspection for certification
D.A fusible link will automatically open after a fire is extinguished and reset the damper
第1题:
conduction
convection
radiation
windage
第2题:
convection
conduction
radiation
direct contact
第3题:
a break-glass and pull-cable system
electrical controls on the bridge
a mechanical arm outside the vent duct
the heat of a fire melting the link
第4题:
contaminating food with extinguishing agent
shutting all sources of air into the compartment
closing the sea chest
a grease fire in the ventilation system
第5题:
8the heat of a fire melting the link
a break-glass and pull-cable system
electrical controls on the bridge
a mechanical arm outside the vent duct
第6题:
remote operated valve
fusible link
CO2 system pressure switch
heat or smoke detector
第7题:
the accumulation of explosive gases
faster cooling of the fire
the fire to spread through the ventilation system
fixed foam systems to be ineffective
第8题:
Use the C02 system and evacuate the engine room
Use the fire main system and evacuate the engine room
Evacuate the engine room and use the C02 system
Evacuate the engine room and use the fire main system
第9题:
Any compartment containing explosives
Any compartment adjacent to one containing explosives
Enclosed spaces which are specially suitable for vehicles
All of the above
第10题:
Engine room ventilation should be started
Main engines should be secured
The fire pump should be started
The fixed CO2 system should be activated
第11题:
transmitting the heat of a fire through the ship s metal
burning liquids flowing into another space
heated gases flowing through ventilation systems
the transfer of heat across an unobstructed space
第12题:
transferring heat across an unobstructed space
heated gases flowing through ventilation systems
burning liquids flowing into another space
transmitting the heat of a fire through the ship's metal
第13题:
A fusible link will automatically open after a fire is extinguished and reset the damper
Fusible links must be replaced at every inspection for certification
Fusible links are tested by applying a source of heat to them
Fusible links must be replaced if a damper is activated
第14题:
heated gases flowing through ventilation systems
the transfer of heat across an unobstructed space
burning liquids flowing into another space
transmitting the heat of a fire through the ship's metal
第15题:
contaminating food with extinguishing agent
spreading through the engineering space
loss of stability
a grease fire in the ventilation system
第16题:
contaminating food with extinguishing agent
spreading through the engineering space
causing loss of stability
a grease fire in the ventilation system
第17题:
remotely operated valves
fusible links
C02 system pressure switches
heat or smoke detectors
第18题:
convection
conduction
radiation
spontaneous combustion
第19题:
The fire pump should be started
The boiler rims should be secured
The fixed CO2 system should be initiated into action
The engine room ventilation should be secured
第20题:
ventilate the quarters as much as possible
prepare to abandon ship
close all ventilation to the quarters if possible
attempt to put the fire out yourself before sounding the alarm
第21题:
convection
conduction
radiation
direct contact
第22题:
maximum pressure allowed at that branch
name of the space or spaces which it serves
date of the last maintenance inspection
pressure needed to maintain an effective stream at that point
第23题:
fixed foam systems to be ineffective
faster cooling of the fire
the accumulation of explosive gases
the fire to spread through the ventilation system