第1题:
Which of the following server chassis types allows for the HIGHEST server density in a rack?()
第2题:
A customer is considering iDataPlex and several competitive solutions. Which of the following favor iDataPlex?()
第3题:
Which of the following solutions provides maximum core density per rack?()
第4题:
A customer is interested in a power efficient server solution. The Sales Specialist has recommended a BladeCenter solution. The customer debates the price is high compared to rack servers. Which of the following should the Sales Specialist emphasize to address the pricing difference?()
第5题:
A manufacturing customer wants a consolidation solution that provides scale-out capability and the highest processor density per rack unit. Which of the following solution meets customer’s requirement?()
第6题:
Use rack specific cabling hardware
Let cables hang loosely behind the servers
Channel all power cables down the sides, and all network cables down the center
Keep cables close to the front of the rack for better access
第7题:
Lowest cost of acquisition
Useable density
Flexible configurations ready for integration and testing at the customers data center
Standard rack mounting
第8题:
A Power 795 with MaxCore mode
A Power 780 with MaxCore mode
A Power 755 with TurboCore mode
A Power 780 with TurboCore mode
第9题:
Usable density
Lowest cost of acquisition
Flexible configurations ready for integration and testing at the customer location
Standard rack mounting
第10题:
Higher rack density that reduces data center footprints
Internal upgrades that only IBM can offer
Total Cost of Ownership (TCO) related to innovative components such as Integrated Switches
The Rear Door Heat eXchanger that only IBM can offer
第11题:
Use rack specific cabling hardware
Let cables hang loosely behind the servers
Channel all power cables down the sides, and all network cables down the center
Keep cables close to the front of the rack for better access
第12题:
Humidity monitors, Biometrics, and fire suppression
Cooling, rack space, and power requirements
Service level agreements, uninterruptible power supply (UPS) deployment, and CCTV
Biometrics, fire suppression, and power requirements
第13题:
Which system provides the highest performance per core, and the least cost for applications licensed per core?()
第14题:
When selling against competition, which of the following focus on the iDataPlex value proposition? ()
第15题:
Which is the packaging strategy of iDataPlex of the following?()
第16题:
A customer has requested five rack mounted servers, and a rack. They want redundant power connections. Which of the following is required to meet these requirements?()
第17题:
Power capping helps mainly in reducing data center footprint.
Power capping helps reduce data center cooling.
A single power cap group policy allows you to set power limits across multiple UCS domains.
You can have multiple power cap groups per UCS domain.
Each blade within a UCS 5108 chassis can belong to a separate power cap group.
第18题:
Redundant power supplies on the servers
Redundant PDUs in the rack
edundant power supplies in the servers and redundant PDUs in the rack
Redundant power supplies in the servers, redundant PDUs in the rack, and Active Energy Manager (AEM)
第19题:
x3650 M3 with Microsoft Virtual Server
BladeCenter JS43 with VMware
x3850 X5 with VMware
BladeCenter HS22V with VMware
第20题:
The Blades must use the same CIOv and CFFh expansion adapter types.
Two physical BladeCenter H chassis will be required. One for the POWER Blades, the other for the x86 Blades.
The x86 Blades and POWER Blades may use different expansion adapters provided the POWER Blades are in bays 1-7 and the x86 Blades are in slots 8-14.
The x86 Blades and POWER Blades may use different expansion adapters, provided the corresponding I/O modules to Blade midplane connections are configured in the Advanced Management Module (AMM).
第21题:
Superior chip density
Balance performance, cost, and power+cooling efficiency
Flexible configurations ready for integration and testing at the customers data center
Standard rack mounting
第22题:
Blade server
Tower converted to rack server
Tower server
Rack server
第23题:
Fourteen servers per rack likeBladeCenter
Two servers per rack for optimal cooling cost
One server per rack for optimal cooling and energy efficiency
Four servers per rack (twoexach half high) for optimal cooling