单选题everal people in an finance customer IT department are asking for fileset updates that the  system administrator received from IBM earlier that day on CD-ROM. The system administrator created an install directory on their machine and made it available 

题目
单选题
everal people in an finance customer IT department are asking for fileset updates that the  system administrator received from IBM earlier that day on CD-ROM. The system administrator created an install directory on their machine and made it available to everyone.  Which of the following commands will allow the system administrator to copy the images from an IBM update CD-ROM to the install directory()
A

smit bffcreate from the target directory

B

tar -xvf /dev/cd0 from the target directory

C

restore -xvqf /dev/cd0 from the target directory

D

mount the cdrom on /cdrom and run cp /cdrom/* . from the target directory


相似考题
更多“单选题everal people in an finance customer IT department are asking for fileset updates that the  system administrator received from IBM earlier that day on CD-ROM. The system administrator created an install directory on their machine and made it available ”相关问题
  • 第1题:

    A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()

    • A、 Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.
    • B、 Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.
    • C、 Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.
    • D、 Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.

    正确答案:D

  • 第2题:

    An IBM XIV system with nine modules and 2 TB disks is being proposed to a customer who needs to increase disk capacity in the data center. The customer is concerned about data growth andcost after the initial purchase. Which of the following factors of the solution should be stressed to the customer to address data growth?()

    • A、the XIV system can be scaled by the addition of modules
    • B、XIV offers thin provisioning for all available host operating systems
    • C、reduced operating costs will pay for another XIV system in less than two years
    • D、the management GUI allows the administrator tovirtualize the entire storage system quickly

    正确答案:A

  • 第3题:

    Several people in an Information Technology (IT) department are asking for fileset updates that the system administrator received earlier that day on CD-ROM. The system administrator created an install directory on their machine and made it available to everyone. Which of the following commands will allow the system administrator to copy the images from the CD-ROM to the install directory?()

    • A、smit bffcreate from the target directory
    • B、tar -xvf /dev/cd0 from the target directory
    • C、restore -xvqf /dev/cd0 from the target directory
    • D、mount the cdrom on /cdrom and cp /cdrom/* . from the target directory

    正确答案:A

  • 第4题:

    A system administrator was able to boot a system from the AIX installation CDROM. The migration install was selected, but the process hung at 92% complete. The system administrator then rebooted the system, which subsequently hung at LED 552. Which of the following options is the most probable cause?()

    • A、The ODM is corrupted.
    • B、There is a hardware failure.
    • C、The bosboot command failed.
    • D、Not enough space is available in the filesystems.

    正确答案:C

  • 第5题:

    The system administrator has created a mksysb to attempt to clone to another system. Which of the following considerations is NOT true?()

    • A、When using a mksysb to clone a system that has had device driver updates applied, the target system does not need to be updated with device driver Updates to match the source systems level, as the mksysb will have the needed drivers.
    • B、CHRP architecture systems cloned form non-CHRP architecture systems with Updates applied may fail to boot due to incompatibilities between the updated kernel in the mksysb image and the base level devices.chrp.base.rte fileset installed during the cloning process.
    • C、If the source and target system kernels are different (for example, rs6k and rspc), one MUST boot from CD-ROM installation media, at the same operating system level as the mksysb being restored.
    • D、The RECOVER_DEVCIES option allows the choice to recover the customized ODM attributes from the mksysb(for example, network addressing, static routes, tty settings, and multi-port adapter cards). The target devices must be in The same location as the source machine, or the install will fail and the device wil not be defined.

    正确答案:A

  • 第6题:

    单选题
    Several people in an Information Technology (IT) department are asking for fileset updates that the system administrator received earlier that day on CD-ROM. The system administrator created an install directory on their machine and made it available to everyone. Which of the following commands will allow the system administrator to copy the images from the CD-ROM to the install directory?()
    A

    smit bffcreate from the target directory

    B

    tar -xvf /dev/cd0 from the target directory

    C

    restore -xvqf /dev/cd0 from the target directory

    D

    mount the cdrom on /cdrom and cp /cdrom/* . from the target directory


    正确答案: C
    解析: 暂无解析

  • 第7题:

    单选题
    everal people in an finance customer IT department are asking for fileset updates that the  system administrator received from IBM earlier that day on CD-ROM. The system administrator created an install directory on their machine and made it available to everyone.  Which of the following commands will allow the system administrator to copy the images from an IBM update CD-ROM to the install directory()
    A

    smit bffcreate from the target directory

    B

    tar -xvf /dev/cd0 from the target directory

    C

    restore -xvqf /dev/cd0 from the target directory

    D

    mount the cdrom on /cdrom and run cp /cdrom/* . from the target directory


    正确答案: A
    解析: 暂无解析

  • 第8题:

    单选题
    An IBM XIV system with nine modules and 2 TB disks is being proposed to a customer who needs to increase disk capacity in the data center. The customer is concerned about data growth andcost after the initial purchase. Which of the following factors of the solution should be stressed to the customer to address data growth?()
    A

    the XIV system can be scaled by the addition of modules

    B

    XIV offers thin provisioning for all available host operating systems

    C

    reduced operating costs will pay for another XIV system in less than two years

    D

    the management GUI allows the administrator tovirtualize the entire storage system quickly


    正确答案: A
    解析: 暂无解析

  • 第9题:

    单选题
    A system administrator was able to boot a system from the AIX installation CDROM. The migration install was selected, but the process hung at 92% complete. The system administrator then rebooted the system, which subsequently hung at LED 552. Which of the following options is the most probable cause?()
    A

    The ODM is corrupted.

    B

    There is a hardware failure.

    C

    The bosboot command failed.

    D

    Not enough space is available in the filesystems.


    正确答案: A
    解析: 暂无解析

  • 第10题:

    单选题
    An install of cluster .es software failed. Output from the failure indicates missing system  requisites. Every subsequent attempt to install the software abended.  In order for the cluster to install,the most likely way for the administrator to resolve this problem is to install the "bos.data" and which other fileset(s)?()
    A

     rsct.*

    B

     xIC* and rsct.*

    C

     bos.adt.* and rsct.*

    D

     csm.*.rte and rsct.*


    正确答案: B
    解析: 暂无解析

  • 第11题:

    单选题
    A retail customer wants to identify the system firmware version information on several IBM System x servers and apply updates as required from a central location without causing server downtime. Which IBM tool provide this capability?()
    A

    CDAT

    B

    Systems Director

    C

    Server Guide

    D

    Tivoli Provisioning Manager for Operational System Deployment (TPMfOSD)


    正确答案: C
    解析: 暂无解析

  • 第12题:

    单选题
    A system administrator is installing a C compiler on a system. According to the compiler’s documenation, the AIX fileset bos.adt.lib must be installed prior to installation of the compiler. Which command would the system administrator use to verify installation of the bos.adt.lib fileset?()
    A

    installp

    B

    instfix

    C

    lsallq

    D

    lslpp


    正确答案: D
    解析: 暂无解析

  • 第13题:

    A major account is considering migrating from a proprietary Unix server to a Linux and Intel-based platform. They are not sure if the Intel-based server will be able to handle the workload of the Unix server.  What would be the best strategy to win with an IBM solution?()

    • A、Suggest to the customer to send their administrator to IBM System x training class to learn more about IBM Intel based servers.
    • B、Propose a try and buy option and offer to help the customer in sizing the new Linux server. Engage the system Engineer on this opportunity.
    • C、Introduce the IBM pSeries Unix product specialist to the account because IBM operating system (AIX) offers an open Unix solution.
    • D、Direct the customer to the IBM Web site to help with sizing and System x server models and types. Follow-up with the customer to answer any sizing question.

    正确答案:B

  • 第14题:

    After updating the system, the system administrator runs the lppchk-v command. During this process, the bos.rte.libc is in a broken state. Which of the following procedures should be performed to fix this problem?()

    • A、Reinstall the system
    • B、Use installp -r to reject the broken fileset
    • C、Use installp -acgFXd to reinstall the fileset at the same level
    • D、Use install -u to remove this broken fileset and reinstall it again

    正确答案:C

  • 第15题:

    A system administrator needs to quickly migrate a machine from AIX 5.1 to AIX 5.2. The administrator will only be allowed enough downtime to reboot the machine. Which installation method should be used to accomplish this task?()

    • A、Perform a migration installation during the reboot process.
    • B、Perform an alternate disk installation and migration using NIM.
    • C、Copy the /usr directory from another 5.2 server to this server.
    • D、Perform an update_all install from 5.2 media to take effect on reboot.

    正确答案:B

  • 第16题:

    A system administrator is installing a C compiler on a system. According to the compiler’s documenation, the AIX fileset bos.adt.lib must be installed prior to installation of the compiler. Which command would the system administrator use to verify installation of the bos.adt.lib fileset?()

    • A、installp
    • B、instfix
    • C、lsallq
    • D、lslpp

    正确答案:D

  • 第17题:

    A system administrator has a mksysb on tape of an AIX 5.2 machine and needs to install it on a different server. How can this be accomplished?()

    • A、Install the base AIX from 5.2 media and then install the mksysb overtop.
    • B、Mount the tape and use the tar command to install AIX and the rest of the contents of the rootvg.
    • C、Insert the mksysb tape and a 5.2 base media CD and then boot to maintenance mode and initiate the install.
    • D、Install AIX 5.2 from base media and then perform an update_all install from the mksysb tape of the original machine.

    正确答案:C

  • 第18题:

    单选题
    The system administrator did a new install of AIX on a server about a week ago. The system was not rebooted after the installation. CDE is running on this system as is TCPIP. The system administrator has started configuring the system percompany directives. The power cable was inadvertently disconnected from the wall causing the sever to lose power. Upon reboot, the system appears to hang during log in from the console or from Xterminals. Which of the following is the most probable cause?()
    A

    It is a hardware problem caused by the power failure.

    B

    There is a network problem, most probably with name resolution.

    C

    Sine the system was never rebooted, devices are marked defined instead of available and need to be activated.

    D

    Some filesets may be marked as broken and need to be reinstalled.


    正确答案: C
    解析: 暂无解析

  • 第19题:

    单选题
    After updating the system, the system administrator runs the lppchk-v command. During this process, the bos.rte.libc is in a broken state. Which of the following procedures should be performed to fix this problem?()
    A

    Reinstall the system

    B

    Use installp -r to reject the broken fileset

    C

    Use installp -acgFXd to reinstall the fileset at the same level

    D

    Use install -u to remove this broken fileset and reinstall it again


    正确答案: D
    解析: 暂无解析

  • 第20题:

    单选题
    A major account is considering migrating from a proprietary Unix server to a Linux and Intel-based platform. They are not sure if the Intel-based server will be able to handle the workload of the Unix server.  What would be the best strategy to win with an IBM solution?()
    A

    Suggest to the customer to send their administrator to IBM System x training class to learn more about IBM Intel based servers.

    B

    Propose a try and buy option and offer to help the customer in sizing the new Linux server. Engage the system Engineer on this opportunity.

    C

    Introduce the IBM pSeries Unix product specialist to the account because IBM operating system (AIX) offers an open Unix solution.

    D

    Direct the customer to the IBM Web site to help with sizing and System x server models and types. Follow-up with the customer to answer any sizing question.


    正确答案: D
    解析: 暂无解析

  • 第21题:

    单选题
    A system administrator needs to quickly migrate a machine from AIX 5.1 to AIX 5.2. The administrator will only be allowed enough downtime to reboot the machine. Which installation method should be used to accomplish this task?()
    A

    Perform a migration installation during the reboot process.

    B

    Perform an alternate disk installation and migration using NIM.

    C

    Copy the /usr directory from another 5.2 server to this server.

    D

    Perform an update_all install from 5.2 media to take effect on reboot.


    正确答案: B
    解析: 暂无解析

  • 第22题:

    单选题
    A system administrator has a mksysb on tape of an AIX 5.2 machine and needs to install it on a different server. How can this be accomplished?()
    A

    Install the base AIX from 5.2 media and then install the mksysb overtop.

    B

    Mount the tape and use the tar command to install AIX and the rest of the contents of the rootvg.

    C

    Insert the mksysb tape and a 5.2 base media CD and then boot to maintenance mode and initiate the install.

    D

    Install AIX 5.2 from base media and then perform an update_all install from the mksysb tape of the original machine.


    正确答案: B
    解析: 暂无解析

  • 第23题:

    单选题
    A customer has an entry level Power System that is currently partitioned and managed by a Hardware Management Console (HMC). For operational reasons, it must be disconnected from the HMC and configured as a new development system.  How should the customer proceed to implement PowerVM Express and Integrated Virtualization Manager (IVM) on this Power System? ()
    A

     Install a VIO server as an additional partition and DLPAR the resources from the existing partition to the VIO server.

    B

     Create a service partition and install a VIO server. This will automatically move resources to the VIO server on reboot of the managed system.

    C

     Delete all the existing LPARs, create a new LPAR and assign all the system resources to this LPAR and then install the VIO server on this LPAR.

    D

     Reset the machine to Manufacturing Default Configuration and install the VIO server on the resulting partition created, which will own all system resources.


    正确答案: D
    解析: 暂无解析

  • 第24题:

    单选题
    The system administrator has created a mksysb to attempt to clone to another system. Which of the following considerations is NOT true?()
    A

    When using a mksysb to clone a system that has had device driver updates applied, the target system does not need to be updated with device driver Updates to match the source systems level, as the mksysb will have the needed drivers.

    B

    CHRP architecture systems cloned form non-CHRP architecture systems with Updates applied may fail to boot due to incompatibilities between the updated kernel in the mksysb image and the base level devices.chrp.base.rte fileset installed during the cloning process.

    C

    If the source and target system kernels are different (for example, rs6k and rspc), one MUST boot from CD-ROM installation media, at the same operating system level as the mksysb being restored.

    D

    The RECOVER_DEVCIES option allows the choice to recover the customized ODM attributes from the mksysb(for example, network addressing, static routes, tty settings, and multi-port adapter cards). The target devices must be in The same location as the source machine, or the install will fail and the device wil not be defined.


    正确答案: D
    解析: 暂无解析