Use lquerypv to read the drive
Use lspv and look at PP Size value
Look on the outside of the drive itself
Use bootinfo to find the LTG on the drive
第1题:
An administrator needs the fastest read/write capabilities with the most redundancy, cost is not afactor. The current data requirement is 750GB but will double in the next year. Which of the following BEST meets these requirements? ()
第2题:
A new array of hard drives has been added to an existing server; however, when the server is booted into the Windows OS the new drives fail to appear in My Computer. From which of the following locations can the new storage drives be added?()
第3题:
A customer has an 8-way p5-570 with eight internal disk drives and AIX 5.2. Which of the following must be added, if anything, to the configuration to support four LPARs, assuming each LPAR requires twodisk drives?()
第4题:
Companycom has just added some new disk drives to a p5 590. The customer needs to know the largest Logical Track Group that these drives will support. What is the best way to locate this information?()
第5题:
A customer has 6.5 TB with 146 GB 15k disk drives on an IBM System Storage DS8700. They want to add 15 TB using 300 GB 15k disk drives. The customer is concerned about performance and wants to know if the DS8700 has the performance capability. What is the appropriate way to model the performance()
第6题:
Company.com needs to add a new file system to an existing volume group that is being made Highly available by HACMP? What is the best procedure that minimizes down time of the applications?()
第7题:
Disk Magic
Capacity Magic
test the workload at an IBM Benchmark Center
test the solution with IBM Storage Performance Center
第8题:
7311-D20 drawer with four disks
Upgrade to AIX 5.3
Fiber adapters to attach to SAN
Nothing
第9题:
chvg -Qn testvg
chlv -Qn testlv
varyoffvg testvg; varyonvg -Qn testvg
varyoffvg testvg; exportvg testvg; importvg -Qn testvg; varyonvg testvg
第10题:
Run lscfg -vl, and check the ROM levels
Run cfgmgr -v, and check the ROM levels
Run inventory scout, and check the installed levels
Run lslpp -l grep devices, and check the filesets installed
第11题:
Use C-SPOC to add the file system while the cluster is running.
Add the file system,and them perform the exportvg and importvg on the required nodes.
Stop the cluster,add the new file system, and synchronize the cluster then restart HACMP.
Break the reservation locks on the disk drives while the cluster is active and add the file system.
第12题:
Back up the data, remove the failing disk from the volume group, then restore the data to the new disk.
Use the migratepv command to move data from one disk to another and then remove the failing disk from the volume group.
Use the mirrorvg command to mirror the data to the new disk, break the mirror and then remove the failing disk from the volume group.
Create a new filesystem on the new disk and use the mv command to move the data to the new filesystem, and then remove the failing disk from the volume group.
第13题:
Which protocol will use a LUN as a way to differentiate the individual disk drives that comprise a targetdevice?()
第14题:
Two new PCs will have a DVD-RW drive for support use. The PCs will be used for Point of Salestransactions and everything will be password protected or disabled. Which of the following is the BEST way to disable the DVD-RW drives?()
第15题:
An administrator has a two-disk volume group (testvg) with one logical volume (testlv) which has just been mirrored across both disk drives. Which of the following commands can be used to turn off quorum()
第16题:
A customer has an IBM System Storage DS5000 and needs to add more disk drives to the unit.There is no record of the configuration for this machine. How can the configuration be retrieved soan upgrade can be configured?()
第17题:
Error log analysis indicates that a disk is starting to fail and will need to be replaced. The failing disk contains multiple logical volumes which span multiple disks. A free disk has been added to the failing disk’s volume group.Which of the following is the most efficient method to move the data from the failing disk to the new disk?()
第18题:
Telnet into the machine and do a shutdown -Fr
Log into ASMI as Administrator and use ASMI menus
Log into the service processor using WebSM and use ASMI menus
Use the off button which is located to the left below the LEDs
第19题:
N6210 with 12 2 TB SATA drives
DS5020 with 24 1 TB SATA drives
Storwize V7000 with 24 1 TB SATA drives
DS3500 with 12 2 TB nearline SAS drives
第20题:
Use RAID 1 with ten 300GB hard drives.
Use RAID 6 with seven 300GB hard drives.
Use RAID 5 with six 300GB hard drives.
Use RAID 10 with ten 300GB hard drives.
第21题:
Use lquerypv to read the drive
Use lspv and look at PP Size value
Look on the outside of the drive itself
Use bootinfo to find the LTG on the drive
第22题:
Enable DHCP server on the HMC
Configure host name and IP address on DNS server
Manually set the IP address of the service processor
Connect a RS-232 cable from the HMC to the service processor
第23题:
Use lquerypv to read the drive
Use lspv and look at PP Size value
Look on the outside of the drive itself
Use bootinfo to find the LTG on the drive
第24题:
SCSI
HBA
ATA
iSCSI