16fibre ports and 0 mega packs
4fibre ports and 8 mega packs
8fibre ports and 4 mega packs
12fibre ports and 0 mega packs
第1题:
A customer is running Microsoft Windows 2003, Sun Solaris, and IBM AIX with a total capacity of20 TB. This customer needs high availability for e-business applications. The servers are currently connected to two EMC Symmetrix subsystems that are running RAID 1. The customer wants to consolidate all storage into an IBM System Storage DS8700. How many Fibre Channel drive sets are needed to satisfy the total capacity for this customer?()
第2题:
A customer has an existing IBM System Storage DS8700 2-way model with 8 mega packs of 300 GB disks and 16 fibre ports. How many additional fibre ports and mega packs can be installed in the base frame()
第3题:
While installing a new IBM System Storage DS5100 into a customer’s data center, it is discoveredthat the customer does not have enough available Fibre Channel ports on their switches. Which ofthe following should have been used to avoid this situation?()
第4题:
A customer has requested an IBM System Storage DS8700 solution to meet the following requirements: - 20% yearly growth - 29,000 IOPS - approximately 50/50 mix of read/write operations - small (4 KB) data transfers The storage specialist has created a Disk Magic model in which each port is capable of approximately 2,900 to 3,100 IOPS. What is the minimum number of ports that should be configured on the DS8700 to handle the projected workload for the first year()
第5题:
A customer wants to install an IBM BladeCenter infrastructure but is concerned about the cost of the full fabric internal fibre switches. Consequently, the customer is considering an N_Port ID Virtualization (NPIV) capable switch.Which of the following should be mentioned to the customer regarding the NPIV switch?()
第6题:
You can not use an NPIV switch in the same IBM BladeCenter chassis as a Cisco Intelligent Ethernet Switch
Using blade servers with the NPIV switch will require more fibre ports on the external fibre switch
Storage devices like Fibre Channel Tape and Disk cannot be attached to the NPIV Switch but must connect to a core fabric switch
The NPIV switch will count against the number of domains in a fabric
第7题:
the Disk Magic configuration report
an engineer from thetelcom providing the dark fiber
the bandwidth calculations
aCompeteLine analysis
第8题:
16fibre ports and 0 mega packs
4fibre ports and 8 mega packs
8fibre ports and 4 mega packs
12fibre ports and 0 mega packs
第9题:
install the Performance Accelerator feature
review the DS Storage Manager Major Event Log (MEL)
add an expansion frame with additionalFibre Channel ports
review the latest TPC for Disk study to identify the source of the performance issue
第10题:
check the output of the vmstat command on LINUX
check the performance reports via Tivoli Storage Productivity Center for Data
check the performance reports via Tivoli Storage Productivity Center for Disk
check the output of the iostat command on AIX
第11题:
8 drive sets of 300 GB drives
4 drive sets of 300 GB drives
14 drive sets of 146 GB drives
18 drive sets of 146 GB drives
第12题:
additional installation of the first and second expansion frame will increase the backend performance capability
the usage of 300 GB/15k FC disks will give the server a high-performance backend capability
performance Accelerator restricts the number of disks connected to one device adapter pair to 32 disks
the second RIO-G loop between the base frame and the first expansion increases the backend performance
第13题:
The Business Partner technical specialist is called to determine if the addition of host ports on an IBM System Storage DS8700 has improved users’ response times for an IBM System p server running SAP. How can the improvement be verified()
第14题:
A customer has installed an IBM System Storage DS8700 with 20 TB of storage, two-way processor version, 32 GB cache, and 16 Fibre Channel ports. The customer is beginning to experience throughput performance issues. To address this performance consideration with minimal cost to the customer, which of the following should be the FIRST step to resolve the problem()
第15题:
A customer has installed an IBM System Storage DS8700 with 20 TB of storage, 32 GB cache, and 16 Fibre Channel ports. The customer is beginning to experience throughput performance issues since they have added new workloads. The customer asks the storage specialist for guidance. Which of the following actions should be recommended as a first step?()
第16题:
A customer wants to purchase an IBM System Storage DS8700 to support a high-performance database environment. Which technical solution gives the customer the best relationship between I/O performance at the machine’s backend vs. capacity installed in the machine()
第17题:
Two DS8700 systems have been proposed for a disk-to-disk BC solution. Each system has 200 TB installed, with a data change rate of 18% per day. Two 2 Gbps CWDM links are in place between the remote data centers with an average utilization rate of 55%. The proposed solution includes additional CWDM ports. Which of the following should justify the additional CWDM ports()
第18题:
8
10
12
16
第19题:
One fibre channel switch
Two fibre channel switches
Two Ethernet cards
Nothing
第20题:
Disk Magic
Capacity Magic
test the workload at an IBM Benchmark Center
test the solution with IBM Storage Performance Center
第21题:
IBM DS5000 Cabling Tool
IBM e-Configurator Tool
IBM Pre-Installation TDA Checklist
IBM Standalone Solutions Configuration Tool
第22题:
perform a Disk Magic study
review eConfig with a technical specialist
confirm that the customer has enough ports available in the SAN infrastructure
submit configuration to IBM System Storage Interoperability Center for validation
第23题:
DS8000 model conversions are generally non-disruptive
a model conversion from DS8100 to DS8700 is disruptive
the DS8100 base frame needs to be sent back to the factory for upgrade
during model conversion the logical configuration can be kept, but the system must be rebooted
第24题:
add an expansion frame with additionalFibre Channel ports
increase the amount of storage by 20 TB
conduct a Disk Magic study to identify the source of the performance issue
add additionalFibre Channel ports to the existing DS8700