Redundant processor pools, UPS, and HACMP
Redundant service processors, HACMP, and mirrored AIX drives
Redundant processor pools, redundant service processors, and HACMP
Redundant power, redundant Virtual I/O Servers, and mirrored AIX drives
第1题:
Company.com has ordered an 8-way p5-570 and plans to deploy four AIX 5L v5.3 LPARs. The pre-installation system design has all eight processors being placed in the shared processor pool, and four Micro-Partitions being assigned resources from the pool. Prior to the implementation of the system, the customer informs the technical specialist that one of the applications is only supported on AIX 5L 5.2. Which of the following changes to the system design should the technical specialist make to accommodate this change?()
第2题:
A customer is interested in obtaining an AIX solution from IBM. They have two primary global requirements: ? Availability (although HACMP is not required) ? Low cost Which of the following approaches should the pSeries technical specialist use to meet the customer’s requirements and ensure customer satisfaction?()
第3题:
A customer has requested five rack mounted servers, and a rack. They want redundant power connections. Which of the following is required to meet these requirements?()
第4题:
Company.com would like to configure a virtual Ethernet between an AIX V5.3 LPAR and an AIX V5.2 LPAR. Which of the following options is necessary to complete this task?()
第5题:
Companycom tells the technical sales specialist that recent announcements state that virtual lan in the datacenter is the best option. The customer wants to use interpartition communication to save on adapters and increase performance. The systems are going to have shared and dedicated processor partitions. Some of the partitions will be running AIX 5.2 and some will be running AIX 5.3. The second p5 590 will be running a mixture of AIX 5.3 and Linux partitions with 2.6 kernel. What limitations of vlan/interpartition communication should be discussed with this customer?()
第6题:
Which of the following items in a single enclosure Power 770 improves Reliability, Availability, and Serviceability?()
第7题:
RDAC
MPIO
SSPC
SDDPCM
第8题:
an additional 1GB RAM to each node.
Another bootable mirrored disk drive.
A 10/100/1000 GB Ethernet adapter to be attached to a redundant switch.
Nothing,because this is a viable cluster solution with no single points of failure.
第9题:
Design the least-cost solution to prevent the competition from winning the business.
Design a disaster recovery (DR) solution and convince the customer why DR is important to their business.
Use the HACMP specialist to design the solution and include HA SmoothStart services as part of the proposal.
Design a solution with redundant parts and explain to the customer the incremental cost associated with the redundancy.
第10题:
Virtual Ethernet uses the system processors for all communication functions instead of offloading that load to processors on network adapter cards. Virtual Ethernet is supported on AIX 5L and Linux 2.5 and above.
Virtual Ethernet can be used within groups of shared OR groups of dedicated processor partitions, but not both simultaneously. Virtual Ethernet comes with AIX 5L, and is supported in AIX 5.2 or AIX 5.3 partitions, but not Linux.
Virtual Ethernet can be used in both shared and dedicated processor partitions. Virtual Ethernet can run in an AIX 5.3 or Linux 2.6 Kernel, but not AIX 5.2 partitions. Virtual Ethernet can only connect partitions within a single system.
Virtual Ethernet uses the system processors for all communication functions instead of offloading that load to processors on network adapter cards. Virtual Ethernet can connect partitions between systems if the HMC is shared between systems.
第11题:
Remove the physical Ethernet adapters from the LPARs
Activate Advanced POWER Virtualization
Update microcode for the virtual adapters
Upgrade AIX V5.2 LPAR to AIX V5.3
第12题:
Any AIX bootable media, providing it is a 64-bit variant
Any AIX bootable media, providing it is AIX 5.1 or later
Any AIX 5.3 bootable media, providing it is TL09 or later
Any AIX 6.1 bootable media, providing it is TL02 or later
第13题:
A p5-550 with AIX 5.3 is being designed for availability. In addition to providing redundant adapters, which of the following should also be provided?()
第14题:
An administrator plans to use bootable AIX media to boot a system into maintenance mode. The system is running AIX 5.3 TL09 with a 64-bit kernel. The administrator has a selection of media available. Which media should the administrator use?()
第15题:
A customer needs a system supporting four partitions, each with the following requirements: ? 0.6 1.65GHz processors ? 2GB memory ? AIX 5.2 They also need the ability to grow the system in the future. Which pSeries system would be positioned best to meet this customer’s requirements?()
第16题:
A cluster administrator has been asked to install HACMP on two nodes with the following hardware: -two CPUs, - 1GB RAM, - one 1 36GB drive, -two 10/100/1000 Ethernet adapters, and -GB Fibre Channel adapters dual attached to SAN storage. In order to eliminate single points of failure,the administrator should first add which of the following:()
第17题:
Company.com has a 2 processor license for SLES 9 and a 2 processor license for AIX V5.3. Which of the following LPAR configurations is valid on a 4-way p5-550?()
第18题:
SLES9:2 dedicated processors AIX: 2.0 processing units,4 virtual processors,uncapped
SLES9:2.0 processing units,2 virtual processors,uncapped AIX:2.0 processing units,4 virtual processors,capped
SLES9:2.0 processing units,3 virtual processors,uncapped AIX:2 dedicated processors SLES9:2.5 processing units,3 virtual processors,capped
AIX:1.5 processing units,2 virtual processors,capped
第19题:
Redundant system clocks
Redundant service processors
eDRAM chips have redundant L3 cache
Main memory DIMMs contain a redundant DRAM chip
第20题:
Redundant power supplies with one power supply connected and one power supply as a hot spare.
Redundant power supplies with each connected to a separate power circuit.
Redundant power supplies connected via a Y-cable.
Redundant power supplies with each connected to the same power circuit.
第21题:
Create all the partitions as AIX 5.2, each having two dedicated processors.
Purchase a system with two additional processors that can be assigned to the AIX 5.2 Partition.
Specify an AIX 5.2 partition using dedicated processors, reducing the number of processors in the shared pool.
Use the virtual I/O server to manage the disks and network connections removing the need for different levels of device drivers.
第22题:
p5-550 with the Advanced POWER Virtualization feature and AIX 5.2
p5-550 with the POWER5 processor technology and AIX 5.2
p5-570 with the Advanced POWER Virtualization feature and AIX 5.3
p5-570 with the POWER5 processor technology and AIX 5.2
第23题:
Dynamic LPAR
Workload Manager
Partition Load Manager
Shared Processor Pools