第1题:
What IBM technology makes it easier for a customer to quickly locate and identify a failed server component? ()
第2题:
A server has a single failed hard drive in an array that is accessed through a hot plug backplane to ease replacement of failed drives. After replacing the drive several times, each of the replacement drives failed to power up and rebuild as the failed drive. Which of the following is the MOST likely cause of the failures?()
第3题:
Which of the following BEST describes the function of a DNS server?()
第4题:
Which of the following BEST describes the function of a redundant power supply?()
第5题:
Which of the following listed diagnostics products provides easy notification and identification of a failed component, even if the power is off? ()
第6题:
A server has been having a memory problem. What feature can be used to determine the failing memory module?()
第7题:
The backplane has failed and needs to be replaced.
The array must be disbanded and recreated from a backup source to recognize the replacement drive.
There is a conflict with the optical drive on the server.
The server power supply is failing and not providing enough power for all the drives.
第8题:
Provides additional diagnostic LEDs
Reduces power consumption
Eliminates a single point of failure
Reduces total cost of ownership
第9题:
Turn off all the equipment in the server closet
Install a fan in the server closet
Turn off the power to the server closet
Follow escalation procedures for emergencies
第10题:
TCP/IP settings
RAID configuration
Whether the power cord is attached
Server room access log
第11题:
an +l
a2n
an+2
a3n
an+4
第12题:
A failed RAID controller
Two failed processors
Two failed sticks of memory
Two failed drives
第13题:
Which of the following products and utilities can be used to update all encrypted data as well as the merchant key in a WebSphere Commerce database for a given instance?()
第14题:
A user is reporting that their computer is making strange noises and randomly powers off. Which of the following tools would MOST likely be used to troubleshoot this problem?()
第15题:
A server has been intermittently shutting off. The power going to the server was tested and is giving the appropriate voltages. Which of the following tools would be used to test the power supply?()
第16题:
There is a power outage and all servers are shut down properly by the uninterruptible power supply(UPS) software. When one of the servers starts up it displays a logical drive failed error. This server has two processors,16GB of memory, and a RAID 5 array with 10 drives. Which of the following is the MOST likely cause?()
第17题:
Which of the following IBM products includes a rich set of tools to monitor the health of System x, BladeCenter-based systems and to automatically take action to minimize costly outages?()
第18题:
Memory Mirroring
Predictive Failure Analysis
Processor Clockspeed
Light Path Diagnostics
第19题:
VPN
RIS
LDAP
RAS
第20题:
Turn off all electrical power
Remove all backup media
Implement fire suppression
Evacuate all personnel
第21题:
Provides additional diagnostic LEDs
Reduces power consumption
Eliminates a single point of failure
Reduces total cost of ownership
第22题:
POST diagnostic card
OTDR
TDR
Multimeter
第23题:
Corrupt file system table
Backplane failure
Multiple drive failure
Bad cable