第1题:
A.Power710
B.Power720
C.Power730
D.Power740
第2题:
Which of the following is the BEST case scenario for power fault tolerance within a server?()
第3题:
Which system provides the highest performance per core, and the least cost for applications licensed per core?()
第4题:
请问下列哪款IBM产品是由IBM负责免费安装的产品?()
第5题:
A customer has requested five rack mounted servers, and a rack. They want redundant power connections. Which of the following is required to meet these requirements?()
第6题:
A customer needs a system supporting four partitions, each with the following requirements: ? 0.6 1.65GHz processors ? 2GB memory ? AIX 5.2 They also need the ability to grow the system in the future. Which pSeries system would be positioned best to meet this customer’s requirements?()
第7题:
An IT director needs to deploy 3 partitions, each using dedicated internal boot disk. Which system will support the customer requirement using the least amount of rack space?()
第8题:
Redundant power supplies with one power supply connected and one power supply as a hot spare.
Redundant power supplies with each connected to a separate power circuit.
Redundant power supplies connected via a Y-cable.
Redundant power supplies with each connected to the same power circuit.
第9题:
A Power 795 with MaxCore mode
A Power 780 with MaxCore mode
A Power 755 with TurboCore mode
A Power 780 with TurboCore mode
第10题:
Provides additional diagnostic LEDs
Reduces power consumption
Eliminates a single point of failure
Reduces total cost of ownership
第11题:
Physically press the appropriate button on the system.
Physically disconnect and reconnect the power cable on the system.
Log into the IVM using a Web Browser, select the managed-system and select the Power on option from the Operations menu.
Log into the HMC using a Web Browser, select the managed-system and select the Power on option from the Operations menu.
第12题:
p5-550 with the Advanced POWER Virtualization feature and AIX 5.2
p5-550 with the POWER5 processor technology and AIX 5.2
p5-570 with the Advanced POWER Virtualization feature and AIX 5.3
p5-570 with the POWER5 processor technology and AIX 5.2
第13题:
Which of the following accurately describes the meaning of redundant cooling?()
第14题:
Which of the following BEST describes the function of a redundant power supply?()
第15题:
Following an unscheduled power outage, theadministrator needs to power up an IVM-managed system. For the given system,what is the first step in this process?()
第16题:
A customer has a new Power 720 with PowerVM Standard Edition. They plan to migrate their single-partition POWER5 550 to the new Power 720. How can the customer migrate from the POWER5 550 to the Power 720 with minimal effort and down time?()
第17题:
A customer requires two 12X loops on their new POWER7 system. What is the smallest system that will support two loops?()
第18题:
Which system provides redundant system clocks?()
第19题:
Redundant power supplies on the servers
Redundant PDUs in the rack
edundant power supplies in the servers and redundant PDUs in the rack
Redundant power supplies in the servers, redundant PDUs in the rack, and Active Energy Manager (AEM)
第20题:
Add a second DVD drive
Add an extended runtime module(ERM) to the UPS
Configure automated system recovery(ASR)
Add a second NIC
第21题:
Redundant system clock
Redundant service processor
POWER7 cores include redundant L3 caches
Main memory DIMMs contain an extra DRAM chip for improved redundancy
第22题:
Perform Live Partition Mobility between the two systems.
Move the boot disks from the old system to the new system.
Use Tivoli Storage Manager to back up the POWER5 550 and restore on the Power 720.
Upgrade AIX to the latest level on the POWER5 550 and clone using the mksysb command.
第23题:
The source of cooling to a RAID system
The cooling system in a redundant power supply
A cooling system that can be installed in case of failure
A second cooling system in case of a failure