The battery on the machine is bad.
The root volume group is corrupted.
The low-level debugger is not enabled.
There is a problem with the CD-ROM.
第1题:
Which of the following types of media would MOST likely cause above normal amounts of machine jamming?()
第2题:
A user is reporting a loud grinding sound when the machine is powered on. The machine loadsinto windows and the user does not notice any performance issues. Which of the following is the MOST likely cause of the noise?()
第3题:
After using the alt_disk_install command to clone a system image to another disk, the system administrator noticed a large number of defined devices not allocated to the LPAR. Which of the following is the most likely cause of this situation?()
第4题:
One of the mirrored disks for the root volume group has failed. Although the logical volumes are mirrored, and the bosboot command was run, the machine will not boot. What is the most probable cause?()
第5题:
A system administrator was able to boot a system from the AIX installation CDROM. The migration install was selected, but the process hung at 92% complete. The system administrator then rebooted the system, which subsequently hung at LED 552. Which of the following options is the most probable cause?()
第6题:
A technician is booting up a computer but the computer never moves beyond POST. The floppydisk drive light stays lit continuously during the boot process. Which of the following is the MOST likely cause?()
第7题:
Establish a new theory of probable cause.
Reverse the change.
Implement the next logical change.
Perform a root cause analysis.
第8题:
Quorum was not turned off
Paging space was not mirrored
The dump space was not mirrored
The surviving disk was too small
第9题:
The ODM is corrupted.
There is a hardware failure.
The bosboot command failed.
Not enough space is available in the filesystems.
第10题:
Verify full system functionality.
Implement the change.
Test the theory to determine the cause.
Root cause analysis.
第11题:
Envelopes
Colored media
Letterhead
Pre punched
第12题:
A corrupted JFS log device
A corrupted boot logical volume
An incorrect rc.boot entry in /etc/inittab file
A problem initializing paging space
第13题:
When an administrator is troubleshooting a system, which of the following describes the NEXT course of action if a change does not solve the problem?()
第14题:
Which of the following describes the FINAL step in the troubleshooting process?()
第15题:
A system administrator is in the process of performing a preservation installation. However, the machine keeps booting up in diagnostic mode. Which of the following is the most probable cause?()
第16题:
When using a mksysb and base media to clone a system, which of the following will cause the installation to fail()
第17题:
A system administrator boots a server in normal mode, the boot process displays and LED 551 and stops. LED 551 indicates the root volume group is being varied on. All of the following are probable causes of the problem EXCEPT:()
第18题:
The battery on the machine is bad.
The root volume group is corrupted.
The low-level debugger is not enabled.
There is a problem with the CD-ROM.
第19题:
It is a hardware problem caused by the power failure.
There is a network problem, most probably with name resolution.
Sine the system was never rebooted, devices are marked defined instead of available and need to be activated.
Some filesets may be marked as broken and need to be reinstalled.
第20题:
mksysb made on a single processor machine but is being installed on a multiple processor machine, no editing of the image.data file
mksysb made on machine with mirrored rootvg and new machine only has one disk in rootvg, no editing of the image.data file
mksysb made on a machine with 32GB of RAM but being installed on a machine with only 8GB of RAM
mksysb made on a machine with virtual Ethernet adapter but being installed on a machine which only has a physical Ethernet adapter
第21题:
The cfgmgr command was not run to reconfigure the devices
The machine was not booted into SMS MultiBoot mode after configuration
The machine was not in full system partition mode when the volume was created
The alt_disk_install command was not run with the -O option to remove references in the ODM
第22题:
Establish a new theory of probable cause.
Reverse the change.
Implement the next logical change.
Perform a root cause analysis.
第23题:
Document the solution and process.
Establish the most probable cause.
Implement and test the solution.
Identify additional symptoms and problems
第24题:
Powersupplyfailure
BadHD
Badfan
FaultyCD-Rom