单选题A file server is setup in a RAID 5 configuration.Recently there was a power failure in the server room while a user was transferring a document from one drive on the server to another drive on the same server.Unfortunately their UPS was in repair durin

题目
单选题
A file server is setup in a RAID 5 configuration.Recently there was a power failure in the server room while a user was transferring a document from one drive on the server to another drive on the same server.Unfortunately their UPS was in repair during this outage, and the file is now corrupt.Which of the following can be done to prevent this situation in the future?()
A

Increase the memory on the server.

B

Reconfigure drives to a RAID 0+1.

C

Install a battery backed write cache module in the system.

D

Instruct the user to save to the local system instead of to the server.


相似考题
参考答案和解析
正确答案: B
解析: 暂无解析
更多“单选题A file server is setup in a RAID 5 configuration.Recently there was a power failure in the server room while a user was transferring a document from one drive on the server to another drive on the same server.Unfortunately their UPS was in repair durin”相关问题
  • 第1题:

    You have a server named Server1 that runs Windows Server 2003 Service Pack 2 (SP2). Server1 runs a custom database application. The database files are stored on drive D. Server1 experiences a power failure. Upon restart, the database engine reports that the log files fail to replay because a log file is corrupt. You need to minimize the risk of a log file becoming corrupt if the power fails. What should you do? ()

    • A、Enable hibernation.
    • B、Enable volume shadow copies.
    • C、Disable read caching on drive.
    • D、Disable write caching on drive.

    正确答案:D

  • 第2题:

    A Windows 2003 server has the operating system installed on a software RAID mirror. After a failure of one disk in the array the server will no longer boot up. The other drive is still functioning. Which of the following should be done to correct the issue? ()

    • A、 Edit the boot.ini file.
    • B、 Change to a hardware RAID solution.
    • C、 Recreate the array.
    • D、 Edit the active drive in the array.

    正确答案:A

  • 第3题:

    Two new servers are purchased and need to be installed to allow sharing of a single external hard drive enclosure.  One server is configured as a local file server, and the other as a database server for a different network.  The onsite technician notices that when both servers are running at the same time, they each receive SCSI errors. When they are running individually, no errors are reported.   Which of the following is the BEST source of information to use for troubleshooting this problem?()

    • A、 the server vendor’s FAQ website
    • B、 the SCSI controller vendor’s user manual
    • C、 the drive enclosure vendor’s user manual
    • D、 the network operating system vendor’s website

    正确答案:C

  • 第4题:

    An administrator reboots a ten drive server, with a RAID 10 array, after a power failure and receives an error logical drive failed. Which of the following is the MOST likely cause?()

    • A、Corrupt file system table
    • B、Backplane failure
    • C、Multiple drive failure
    • D、Bad cable

    正确答案:B

  • 第5题:

    You have a server named Server1 that runs Windows Server 2003 Service Pack 2 (SP2). Server1 runs a custom database application. The database files are stored on drive D. Server1 experiences a power failure. Upon restart, the database engine reports that the log files fail to replay because a log file is corrupt. You need to minimize the risk of a log file becoming corrupt if the power fails. What should you do? ()

    • A、Enable hibernation.
    • B、Enable volume shadow copies.
    • C、Disable read caching on drive 
    • D、Disable write caching on drive

    正确答案:D

  • 第6题:

    单选题
    After performing the initial steps in installing the server OS from a DVD-ROM, the server reboots and goes back into the setup wizard. Which of the following is the MOST likely cause for this problem?()
    A

    The DVD-ROM drive has failed.

    B

    An installation file copied from the DVD to the hard drive is corrupt.

    C

    Faulty OS installation DVD

    D

    Incorrect boot sequence in the BIOS


    正确答案: D
    解析: 暂无解析

  • 第7题:

    单选题
    You have a server named Server1 that runs Windows Server 2003 Service Pack 2 (SP2). Server1 runs a custom database application. The database files are stored on drive D. Server1 experiences a power failure. Upon restart, the database engine reports that the log files fail to replay because a log file is corrupt. You need to minimize the risk of a log file becoming corrupt if the power fails. What should you do? ()
    A

    Enable hibernation.

    B

    Enable volume shadow copies.

    C

    Disable read caching on drive 

    D

    Disable write caching on drive


    正确答案: C
    解析: 暂无解析

  • 第8题:

    单选题
    You have a server named Server1 that runs Windows Server 2003 Service Pack 2 (SP2). Server1 runs a custom database application. The database files are stored on drive D. Server1 experiences a power failure. Upon restart, the database engine reports that the log files fail to replay because a log file is corrupt. You need to minimize the risk of a log file becoming corrupt if the power fails. What should you do? ()
    A

    Enable hibernation.

    B

    Enable volume shadow copies.

    C

    Disable read caching on drive.

    D

    Disable write caching on drive.


    正确答案: D
    解析: 暂无解析

  • 第9题:

    单选题
    A server contains a 3 disk RAID 5 array. The red LED is illuminated on one of the drives. Which of the following should the server administrator perform?()
    A

    Replace the drive

    B

    Restore the drive from backup

    C

    Reboot the server

    D

    Reconfigure RAID 5 to RAID 10


    正确答案: A
    解析: 暂无解析

  • 第10题:

    单选题
    After a server inspection, an administrator notices a single drive failure on a server configured with RAID 5. Which of the following is the NEXT step to start rebuilding the array?()
    A

    Reestablish the mirror array.

    B

    Perform online volume expansion.

    C

    Insert hot plug drive.

    D

    Move data to another volume.


    正确答案: A
    解析: 暂无解析

  • 第11题:

    单选题
    Companycom has five LPARs, but only one CD drive. How should the CD drive be shared among all the users without system administrator action?()
    A

    Allocate the CD to the VIO Server and NFS export the CD to the user LPARs

    B

    Allocate the CD to one of the user LPARs and config the VIO Server to NFS import it

    C

    Allocate the CD to the VIO Server and the LPARs will share it as a Virtual SCSI device

    D

    Allocate the CD to one of the user LPARs and NFS export it to the remaining user LPARs


    正确答案: A
    解析: 暂无解析

  • 第12题:

    单选题
    There is a power outage and all servers are shut down properly by the uninterruptible power supply (UPS) software. When one of the servers starts up it displays a logical drive failed error. This server has two processors, 16GB of memory, and a RAID 5 array with 10 drives. Which of the following is the MOST likely cause?()
    A

    A failed RAID controller

    B

    Two failed processors

    C

    Two failed sticks of memory

    D

    Two failed drives


    正确答案: C
    解析: 暂无解析

  • 第13题:

    After a server inspection, an administrator notices a single drive failure on a server configured with RAID 5. Which of the following is the NEXT step to start rebuilding the array?()

    • A、Reestablish the mirror array.
    • B、Perform online volume expansion.
    • C、Insert hot plug drive.
    • D、Move data to another volume.

    正确答案:C

  • 第14题:

    A server contains a 3 disk RAID 5 array. The red LED is illuminated on one of the drives. Which of the following should the server administrator perform?()

    • A、Replace the drive
    • B、Restore the drive from backup
    • C、Reboot the server
    • D、Reconfigure RAID 5 to RAID 10

    正确答案:A

  • 第15题:

    A file server is setup in a RAID 5 configuration.Recently there was a power failure in the server room while a user was transferring a document from one drive on the server to another drive on the same server.Unfortunately their UPS was in repair during this outage, and the file is now corrupt.Which of the following can be done to prevent this situation in the future?()

    • A、Increase the memory on the server.
    • B、Reconfigure drives to a RAID 0+1.
    • C、Install a battery backed write cache module in the system.
    • D、Instruct the user to save to the local system instead of to the server.

    正确答案:C

  • 第16题:

    Companycom has five LPARs, but only one CD drive. How should the CD drive be shared among all the users without system administrator action?()

    • A、Allocate the CD to the VIO Server and NFS export the CD to the user LPARs
    • B、Allocate the CD to one of the user LPARs and config the VIO Server to NFS import it
    • C、Allocate the CD to the VIO Server and the LPARs will share it as a Virtual SCSI device
    • D、Allocate the CD to one of the user LPARs and NFS export it to the remaining user LPARs

    正确答案:D

  • 第17题:

    You are the network administrator for TestKing. The network consists of a single Active Directory domain that contains five member servers running Windows 2000 Server. All five servers have CD-ROM drives and floppy disk drives. You purchase a new computer that has a CD-RW drive. This computer does not currently have a floppy disk drive, but you plan to install one eventually. You install and configure Windows Server 2003 and Recovery Console on the new computer. You configure it as a member server named Testking6. Now you need to ensure that Testking6 can be restored in the event of an operating system failure. Which two actions should you perform? ()(Each correct answer presents part of the solution. Choose two.)

    • A、Copy Asr.sif, Asrpnp.sif, and Autorun.exe from the appropriate directories on Testking6 to another server. Copy the same files to a CD-Rom.
    • B、Copy Asr.sif and Asrpnp.sif from the appropriate directory on Testking6 to another server. Copy the same files to a floppy disk.
    • C、Start the Automated System Recovery wizard on Testking6.
    • D、Start the Create an Emergency Repair Disk wizard on Testking6.
    • E、Copy Autoexec.nt, Config.nt, Setup.log, and Autorun.exe from the appropriate directories on Testking6 to another server. Copy the same files to a CD-Rom.
    • F、Copy Autoexec.nt, Config.nt, and Setup.log from the appropriate directories on Testking6 to another server. Copy the same files to a floppy disk.

    正确答案:B,C

  • 第18题:

    单选题
    Two new servers are purchased and need to be installed to allow sharing of a single external hard drive enclosure.  One server is configured as a local file server, and the other as a database server for a different network.  The onsite technician notices that when both servers are running at the same time, they each receive SCSI errors. When they are running individually, no errors are reported.   Which of the following is the BEST source of information to use for troubleshooting this problem?()
    A

     the server vendor’s FAQ website

    B

     the SCSI controller vendor’s user manual

    C

     the drive enclosure vendor’s user manual

    D

     the network operating system vendor’s website


    正确答案: D
    解析: 暂无解析

  • 第19题:

    单选题
    After installing a new hard drive into a server for the purpose of mirroring the data from the first drive to the second one, the server displays an “operating system not found” error. Which of the following should the technician do to boot the server from the original drive?()
    A

    Replace the second drive with a hot swappable one.

    B

    Swap the drive boot order in the BIOS

    C

    Make the second disk active under the disk management tool.

    D

    Rebuild the array using the hardware RAID tool at boot.


    正确答案: C
    解析: 暂无解析

  • 第20题:

    单选题
    A Windows 2003 server has the operating system installed on a software RAID mirror. After a failure of one disk in the array the server will no longer boot up. The other drive is still functioning. Which of the following should be done to correct the issue? ()
    A

     Edit the boot.ini file.

    B

     Change to a hardware RAID solution.

    C

     Recreate the array.

    D

     Edit the active drive in the array.


    正确答案: C
    解析: 暂无解析

  • 第21题:

    单选题
    A customer with three Windows servers wants to create a shared storage array. One server runs a200 GB Oracle database with high transaction rates. The second server is a file server with 3 TBof data and the third server is a mail server with 150 GB of storage. The key customer decisionmaker has only purchased EMC CX storage products in his previous employment. Cost is a keyconsideration. From the following which is a key feature that could convince the customer topurchase a DS3500 over an EMC CX storage system?()
    A

     SATA and SAS 2.0 disk drive technology can be mixed in different enclosures 

    B

     nearline SAS 2.0 and SAS 2.0 disk drive technology can be mixed in the same enclosure

    C

     SATA disk drive technology can provide both the high transaction rates and large drive sizesneeded for this solution 

    D

     SAS 2.0 disk drive technology can provide both the high transaction rates and large drive sizesneeded for this solution


    正确答案: A
    解析: 暂无解析

  • 第22题:

    单选题
    A file server is setup in a RAID 5 configuration.Recently there was a power failure in the server room while a user was transferring a document from one drive on the server to another drive on the same server.Unfortunately their UPS was in repair during this outage, and the file is now corrupt.Which of the following can be done to prevent this situation in the future?()
    A

    Increase the memory on the server.

    B

    Reconfigure drives to a RAID 0+1.

    C

    Install a battery backed write cache module in the system.

    D

    Instruct the user to save to the local system instead of to the server.


    正确答案: C
    解析: 暂无解析

  • 第23题:

    单选题
    An administrator reboots a ten drive server, with a RAID 10 array, after a power failure and receives an error logical drive failed. Which of the following is the MOST likely cause?()
    A

    Corrupt file system table

    B

    Backplane failure

    C

    Multiple drive failure

    D

    Bad cable


    正确答案: B
    解析: 暂无解析

  • 第24题:

    单选题
    An administrator reboots a ten drive server, with a RAID 10 array, after a power failure and receives an error logical drive failed.  Which of the following is the MOST likely cause?()
    A

     Corrupt file system table

    B

     Backplane failure

    C

     Multiple drive failure

    D

     Bad cable


    正确答案: B
    解析: 暂无解析