UPS form factor
Server form factor
Server power supplys wattage rating
Desired runtime
第1题:
Which of the following is the MOST likely to cause a server power supply fan to fail but allows the power supply to still be functional?()
第2题:
A Windows server has rebooted by itself several times.There are several functioning non-Windows servers in the same rack that are connected to the same uninterruptible power supply(UPS).Which of the following is the MOST likely cause of the reboots?()
第3题:
A technician has found that the uninterruptible power supply (UPS) connected to a server does not have sufficient battery power to allow the server to shutdown gracefully. Which of the following is the MOST cost effective way to allow this server to shutdown gracefully?()
第4题:
When purchasing a UPS for a server room, which of the following are important factors to consider?()
第5题:
Which of the following is the MOST important physical consideration when deploying a new server?()
第6题:
Which of the following is the MOST important physical consideration when deploying a new server?()
第7题:
Network card configuration
Remote access procedures
Estimated runtime
Maximum load
Power cord length
第8题:
Verify uninterruptible power supply (UPS) load
Verify if server consumes 220V
Verify CPU load
Verify if server consumes 110V
第9题:
Humidity monitors, Biometrics, and fire suppression
Cooling, rack space, and power requirements冷
Service level agreements, uninterruptible power supply (UPS) deployment, and CCTV
Biometrics, fire suppression, and power requirements
第10题:
Verify uninterruptible power supply (UPS) load
Verify if server consumes 220V
Verify CPU load
Verify if server consumes 110V
第11题:
UPS form factor
Server form factor
Server power supplys wattage rating
Desired runtime
第12题:
A failed RAID controller
Two failed processors
Two failed sticks of memory
Two failed drives
第13题:
An administrator is working on a rack mount server with all newly installed equipment. Theuninterruptible power supply (UPS) in the rack starts beeping loudly. Which of the following is the FIRST troubleshooting step that should be taken?()
第14题:
Which of the following is MOST useful in HVAC planning? ()
第15题:
An administrator will replace five current servers. Which of the following is the MOST important to review before installing new servers?()
第16题:
Which of the following factors is the MOST important to consider when choosing an uninterruptible power supply (UPS) for a single server? ()
第17题:
There is a power outage and all servers are shut down properly by the uninterruptible power supply(UPS) software. When one of the servers starts up it displays a logical drive failed error. This server has two processors,16GB of memory, and a RAID 5 array with 10 drives. Which of the following is the MOST likely cause?()
第18题:
Which of the following can occur if the maximum rated load is exceeded on an uninterruptible power supply (UPS)?()
第19题:
Add a second DVD drive
Add an extended runtime module(ERM) to the UPS
Configure automated system recovery(ASR)
Add a second NIC
第20题:
Ensure that the power cable for the UPS is plugged in.
Ensure the battery in the UPS is still good.
Check the smart cable connecting the UPS to the server.
Reset the UPS to determine if the problem persists.
第21题:
Install a second UPS.
Increase the size of the swapfile.
Increase the size of the pagefile.
Install an extended battery pack into the UPS
第22题:
The UPS is malfunctioning.
The user traffic to the server is too high.
A BSOD is occurring.
The non-Windows servers cannot be located on the same UPS as the Windows server.
第23题:
There is a fire hazard potential if a power outage occurs.
The last system plugged into the UPS will not be provided any power.
The UPS will draw more power from the circuit to compensate.
The runtime of the UPS will be insufficient if a power outage occurs.
第24题:
Humidity monitors, Biometrics, and fire suppression
Cooling, rack space, and power requirements
Service level agreements, uninterruptible power supply (UPS) deployment, and CCTV
Biometrics, fire suppression, and power requirements