单选题Company.com wants to put two Micro-Partitions on a p5-570 and attach to a SAN. What is the best LPAR configuration to maximize SAN availability using four Host Bus Adapters (HBAs)?()A Two HBAs assigned to each redundant VIOS which provides VSCSI access

题目
单选题
Company.com wants to put two Micro-Partitions on a p5-570 and attach to a SAN. What is the best LPAR configuration to maximize SAN availability using four Host Bus Adapters (HBAs)?()
A

Two HBAs assigned to each redundant VIOS which provides VSCSI access to LUNs

B

Two HBAs assigned to each LPAR with each LPAR owning HBAs on the same PCI busses

C

Two HBAs assigned to each LPAR with each LPAR owning HBAs on separate PCI busses

D

One HBA assigned to each LPAR and two HBAs assigned to a VIOS providing VSCSI access to LUNs


相似考题
更多“单选题Company.com wants to put two Micro-Partitions on a p5-570 and attach to a SAN. What is the best LPAR configuration to maximize SAN availability using four Host Bus Adapters (HBAs)?()A Two HBAs assigned to each redundant VIOS which provides VSCSI access”相关问题
  • 第1题:

    A customer plans to install ten Microsoft Windows servers, three Linux servers, and five AIX servers, with two Fibre Channel host bus adapters each as part of an IBM DS8700 implementation. What multipathing driver is required to build a redundant solution?()

    • A、RDAC
    • B、MPIO
    • C、SSPC
    • D、SDDPCM

    正确答案:B

  • 第2题:

    A customer has an 8-way p5-570 with eight internal disk drives and AIX 5.2.  Which of the following must be added, if anything, to the configuration to support four LPARs, assuming each LPAR requires twodisk drives?()

    • A、7311-D20 drawer with four disks
    • B、Upgrade to AIX 5.3
    • C、Fiber adapters to attach to SAN
    • D、Nothing

    正确答案:D

  • 第3题:

    A customer has an existing DS5300 system attached to two Brocade switches with eight Windowsservers. The customer wants to add their System i p750 server to this SAN. From the followingchoices what is the simplest and least expensive solution for this customer?()

    • A、add twofibre HBAs to the System i and connect to the SAN
    • B、add twofibre HBAs to the System i and connect to the Windows Servers
    • C、add twofibre HBAs to the System i and connect to the System i using VIOS
    • D、add two SAS HBAs to the Systemi array and connect directly to the DS5300

    正确答案:A

  • 第4题:

    A company wants a solution to consolidate their storage using the DS4000 series and implement a disaster recovery solution across two data centers linked by fibre to duplicate the production environment.The customer requires a solution with the least amount of system administration.  Which configuration would provide the best solution?()

    • A、Implement one DS4400 at each location connected to the fibre link and use Remote Volume Mirror (RVM).
    • B、Implement a DS4400 at each location using FlashCopy option and use host based replication to synchronize the sites.
    • C、Implement a switched fabric using redundant SAN switches with a DS4300 using RVM option at each location.
    • D、Implement a switched fabric using SAN switches connected via ISL with a DS4300 using RVM option at each location.

    正确答案:D

  • 第5题:

    A customer is adding a new p5 machine to their environment.  The machine will host several DB2 partitions running AIX 5.2.  They currently have two SAN directors and an IBM ESS.  The SAN design allows for concurrent maintenance.  What is required on each partition to attach to the SAN?()

    • A、A minimum of two HBAs; the customer will need to download SDD
    • B、A minimum of four HBAs; the customer will need to download SDD
    • C、A minimum of two HBAs; the customer will need to configure MPIO
    • D、A minimum of four HBAs; the customer will need to configure MPIO

    正确答案:A

  • 第6题:

    单选题
    A customer plans to install ten Microsoft Windows servers, three Linux servers, and five AIX servers, with two Fibre Channel host bus adapters each as part of an IBM DS8700 implementation. What multipathing driver is required to build a redundant solution?()
    A

    RDAC

    B

    MPIO

    C

    SSPC

    D

    SDDPCM


    正确答案: C
    解析: 暂无解析

  • 第7题:

    单选题
    A customer has an existing DS5300 system attached to two Brocade switches with eight Windowsservers. The customer wants to add their System i p750 server to this SAN. From the followingchoices what is the simplest and least expensive solution for this customer?()
    A

    add twofibre HBAs to the System i and connect to the SAN

    B

    add twofibre HBAs to the System i and connect to the Windows Servers

    C

    add twofibre HBAs to the System i and connect to the System i using VIOS

    D

    add two SAS HBAs to the Systemi array and connect directly to the DS5300


    正确答案: D
    解析: 暂无解析

  • 第8题:

    单选题
    A company wants a solution to consolidate their storage using the DS4000 series and implement a disaster recovery solution across two data centers linked by fibre to duplicate the production environment.The customer requires a solution with the least amount of system administration.  Which configuration would provide the best solution?()
    A

    Implement one DS4400 at each location connected to the fibre link and use Remote Volume Mirror (RVM).

    B

    Implement a DS4400 at each location using FlashCopy option and use host based replication to synchronize the sites.

    C

    Implement a switched fabric using redundant SAN switches with a DS4300 using RVM option at each location.

    D

    Implement a switched fabric using SAN switches connected via ISL with a DS4300 using RVM option at each location.


    正确答案: D
    解析: 暂无解析

  • 第9题:

    单选题
    Which of the following offers the highest level of redundancy in the design of a storage system?()
    A

     A Dual Port HBA with a pair of Point-To-Point connections to the SAN.

    B

     Two Single Port HBAs connected to a fiber switch.

    C

     A Dual Port HBA with a Point-To-Point connection to a SAN.

    D

     Two Dual Port HBAs connected to a pair of fiber switches.


    正确答案: D
    解析: 暂无解析

  • 第10题:

    单选题
    A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()
    A

    Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAs

    B

    Move the existing physical network and storage adapters to the new system and virtualize the I/O using a  single VIO Server.

    C

    Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC  connectors and dual HBAs.

    D

    Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC  connectors and the other with dual HBAs.


    正确答案: A
    解析: 暂无解析

  • 第11题:

    单选题
    Which of the following is true concerning best design practices at the switched Access layer of thetraditional layer2 Enterprise Campus Network?()
    A

     Cisco NSF with SSO and redundant supervisors has the most impact on the campus in theAccess layer

    B

     Provides host-level redundancy by connecting each end device to 2 separate Access switches 

    C

     Offer default gateway redundancy by using dual connections from Access switches toredundant Distribution layer switches using a FHRP

    D

     Include a link between two Access switches to support summarization of routing information


    正确答案: D
    解析: 暂无解析

  • 第12题:

    单选题
    A company has two x346 servers each attached to their own EXP400 containing 367GB of raw SCSI storage.  They want to consolidate their storage infrastructure into a scalable, high availability solution at minimum cost.  Which of the following storage solutions best satisfies the customer’s requirements?()
    A

    Add redundant Fibre HBAs to each server and direct attach them to a DS4300 Turbo SAN solution

    B

    Add iSCSI cards to the servers and direct attach them to a DS300 dual controller model

    C

    Use clustered NAS solution with redundant gigabit network connections

    D

    Add redundant Fibre HBAs to each server and attach them to a DS400 dual controller model


    正确答案: A
    解析: 暂无解析

  • 第13题:

    Which of the following is true concerning best design practices at the switched Access layer of thetraditional layer2 Enterprise Campus Network?()

    • A、 Cisco NSF with SSO and redundant supervisors has the most impact on the campus in theAccess layer
    • B、 Provides host-level redundancy by connecting each end device to 2 separate Access switches 
    • C、 Offer default gateway redundancy by using dual connections from Access switches toredundant Distribution layer switches using a FHRP
    • D、 Include a link between two Access switches to support summarization of routing information

    正确答案:C

  • 第14题:

    A small organization is purchasing a POWER5 to consolidate four applications. Currently, each application has two Host Bus Adapters (HBA) connected to an Enterprise Storage Server (ESS). The customer is concerned about the cost of purchasing eight new HBAs. Which feature of virtualization will be most beneficial to this organization?()

    • A、Virtual Ethernet
    • B、Micro-Partitioning
    • C、Virtual I/O Server
    • D、Capped and uncapped partitions

    正确答案:C

  • 第15题:

    A customer has several single partition POWER5 and POWER6 processor-based systems housed in regional data centers and wants to consolidate into a single Power 770. They must minimize overall cost and the number of adapters, while ensuring a reliable infrastructure. Which solution addresses the customer requirements?()

    • A、Move the storage into a common SAN and virtualize the I/O using a single VIO Server with dual NIC connectors and dual HBAs
    • B、Move the existing physical network and storage adapters to the new system and virtualize the I/O using a  single VIO Server.
    • C、Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, each with dual NIC  connectors and dual HBAs.
    • D、Move the storage into a common SAN and virtualize the I/O using dual VIO Servers, one with dual NIC  connectors and the other with dual HBAs.

    正确答案:C

  • 第16题:

    A company has two x346 servers each attached to their own EXP400 containing 367GB of raw SCSI storage.  They want to consolidate their storage infrastructure into a scalable, high availability solution at minimum cost.  Which of the following storage solutions best satisfies the customer’s requirements?()

    • A、Add redundant Fibre HBAs to each server and direct attach them to a DS4300 Turbo SAN solution
    • B、Add iSCSI cards to the servers and direct attach them to a DS300 dual controller model
    • C、Use clustered NAS solution with redundant gigabit network connections
    • D、Add redundant Fibre HBAs to each server and attach them to a DS400 dual controller model

    正确答案:D

  • 第17题:

    A customer is purchasing a 12-way p5-570 to run light development workloads on eight AIX 5.3 partitions with two network adapters each.  When the current network configuration was reviewed, it was discovered that they only have four Ethernet ports available on their network switch.  Which of the following solutions would prevent them from having to buy another network switch or hub?()

    • A、Add two HMCs with two Ethernet adapters each and run EtherChannel for the original eight partitions.
    • B、Add two HMCs with two Ethernet adapters each and run Virtual Ethernet for the original eight partitions.
    • C、Add two hosting partitions with two Ethernet adapters each and run EtherChannel for the original eight partitions.
    • D、Add two hosting partitions with two Ethernet adapters each and run Virtual Ethernet for the original eight partitions.

    正确答案:D

  • 第18题:

    单选题
    A customer is adding a new p5 machine to their environment.  The machine will host several DB2 partitions running AIX 5.2.  They currently have two SAN directors and an IBM ESS.  The SAN design allows for concurrent maintenance.  What is required on each partition to attach to the SAN?()
    A

    A minimum of two HBAs; the customer will need to download SDD

    B

    A minimum of four HBAs; the customer will need to download SDD

    C

    A minimum of two HBAs; the customer will need to configure MPIO

    D

    A minimum of four HBAs; the customer will need to configure MPIO


    正确答案: D
    解析: 暂无解析

  • 第19题:

    单选题
    Company.com wants to put two Micro-Partitions on a p5-570 and attach to a SAN. What is the best LPAR configuration to maximize SAN availability using four Host Bus Adapters (HBAs)?()
    A

    Two HBAs assigned to each redundant VIOS which provides VSCSI access to LUNs

    B

    Two HBAs assigned to each LPAR with each LPAR owning HBAs on the same PCI busses

    C

    Two HBAs assigned to each LPAR with each LPAR owning HBAs on separate PCI busses

    D

    One HBA assigned to each LPAR and two HBAs assigned to a VIOS providing VSCSI access to LUNs


    正确答案: D
    解析: 暂无解析

  • 第20题:

    单选题
    A customer is purchasing a 12-way p5-570 to run light development workloads on eight AIX 5.3 partitions with two network adapters each.  When the current network configuration was reviewed, it was discovered that they only have four Ethernet ports available on their network switch.  Which of the following solutions would prevent them from having to buy another network switch or hub?()
    A

    Add two HMCs with two Ethernet adapters each and run EtherChannel for the original eight partitions.

    B

    Add two HMCs with two Ethernet adapters each and run Virtual Ethernet for the original eight partitions.

    C

    Add two hosting partitions with two Ethernet adapters each and run EtherChannel for the original eight partitions.

    D

    Add two hosting partitions with two Ethernet adapters each and run Virtual Ethernet for the original eight partitions.


    正确答案: C
    解析: 暂无解析

  • 第21题:

    单选题
    A customer has an 8-way p5-570 with eight internal disk drives and AIX 5.2.  Which of the following must be added, if anything, to the configuration to support four LPARs, assuming each LPAR requires twodisk drives?()
    A

    7311-D20 drawer with four disks

    B

    Upgrade to AIX 5.3

    C

    Fiber adapters to attach to SAN

    D

    Nothing


    正确答案: D
    解析: 暂无解析

  • 第22题:

    单选题
    A small organization is purchasing a POWER5 to consolidate four applications. Currently, each application has two Host Bus Adapters (HBA) connected to an Enterprise Storage Server (ESS). The customer is concerned about the cost of purchasing eight new HBAs. Which feature of virtualization will be most beneficial to this organization?()
    A

    Virtual Ethernet

    B

    Micro-Partitioning

    C

    Virtual I/O Server

    D

    Capped and uncapped partitions


    正确答案: B
    解析: 暂无解析

  • 第23题:

    单选题
    Company.com has two POWER5 servers. They want the two servers’ virtual Ethernets to appear on the same IP subnet. Which of the following will connect the client virtual Ethernet adapters to the physical Ethernet switch connecting the two servers?()
    A

    Configure a Shared Ethernet Adapter on the Virtual I/O Server.

    B

    Use the same virtual LAN ID on each LPAR.

    C

    Set up IP routing through an LPAR on each system.

    D

    Set up an IP firewall through an LPAR on each system.


    正确答案: B
    解析: 暂无解析