mkvdev -sea ent2 -vadapter ent0 -default ent0 -defaultid 1
mkdev -virtual ent0 -adapter ent3 -default en2 -defaultid 1
mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1
mkvdev ent0 -sea -vadapter ent2 -default ent2 -defaultid 1
第1题:
A customer is planning on having a single Virtual I/O Server (VIOS) configuration in a Power 750. They haveselected a 4-port 1Gb Integrated Virtual Ethernet (IVE). There will be no other network cards installed in the system. One IVE logical port will be used in the VIO Server and will be used as the physicalport in a Shared Ethernet Adapter (SEA). What is the maximum number of IVE logical ports available to use inother LPARs?()
第2题:
Which of the following commands is used to display detailed ethernet statistics for ent0?()
第3题:
Company.com has two POWER5 servers. They want the two servers’ virtual Ethernets to appear on the same IP subnet. Which of the following will connect the client virtual Ethernet adapters to the physical Ethernet switch connecting the two servers?()
第4题:
Company.com has a VIO server with a configured virtual Ethernet adapter and a physical Ethernet adapter with an IP address on their local public network. They want to re-configure the physical Ethernet adapter as Shared Ethernet Adapter. When the mkvdev command is run, the following method error is returned: /usr/lib/methods/cfgsea . Which of the following will most likely resolve the problem?()
第5题:
When configuring Shared Ethernet Adapter (SEA) failover between two VIO servers, which of the following attributes must have a different value on both VIO servers?()
第6题:
Run cfgdev on the VIO server and re-run the mkvdev command.
Run chdev -a sea_enable=yes on the physical Ethernet adapter.
Remove and re-add the virtual Ethernet adapter.
Remove the IP address from the physical adapter and re-run the mkvdev command.
第7题:
mkvdev -lnagg ent0,ent1
mkdev -lnagg -d ent0,ent1
mkvdev -t etherchannel -a ent0,ent1
mkdev -c adapter -s pseudo -t etherchannel ent0,ent1
第8题:
1
7
15
31
第9题:
A virtual Ethernet adapter can only connect to other partitions within the same system.
A virtual Ethernet adapter needs to be connected to an external VLAN capable switch to be able to communicate with other partitions on the same system.
A partition can support an unlimited number of virtual Ethernet devices.
A virtual Ethernet adapter in the VIO Server that is part of a SEA should not have the trunk flag set
第10题:
HA Mode
Trunk priority
Control Channel
Default VLAN ID
第11题:
The physical port can be used as part of a Shared Ethernet Adapter (SEA).
All physical ports on the Host Ethernet Adapter (HEA) default to promiscuous mode.
Multiple logical ports can be assigned to a physical port if that logical port is in promiscuous mode.
All physical ports that belong to the same port group will be set to promiscuous mode on the Host Ethernet Adapter (HEA).
第12题:
mkvdev -sea ent2 -vadapter ent0 -default ent0 -defaultid 1
mkdev -virtual ent0 -adapter ent3 -default en2 -defaultid 1
mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1
mkvdev ent0 -sea -vadapter ent2 -default ent2 -defaultid 1
第13题:
Company.com has installed and configured a VIO server utilizing a Shared Ethernet Adapter and is investigating some network performance issues visible on the clients. The customer wants to understand the total network connectivity from the clients out to the data center routers. Which of the following commands will identify the Shared Ethernet Adapter mapping?()
第14题:
Companycom will be using the Virtual IO Server to share both FC and Ethernet adapters among multiple LPARs. The customer is using mostly web services in the LPARs. Which of the following should be considered?()
第15题:
A technical specialist defined a virtual Ethernet ent2 on the VIO server that has a physical adapter, ent0. Which of the following commands should be used to configure the Shared Ethernet Adapter?()
第16题:
Which of the following allows the user to have two separate Ethernet networks share the same network adapter?()
第17题:
Which of the following is a true statement when promiscuous mode is enabled on an Integrated Virtual Ethernet?()
第18题:
ifconfig -a
netstat -nr
lsmap -all -net
lsdev -Cc adapter
第19题:
ifconfig ent0
entstat -d ent0
netstat -i
lscfg -vl ent0
第20题:
mkvdev -sea ent1 -vadapter ent2 -default ent1 -defaultid 1
mkvdev -sea ent1 -vadapter ent0 -vadapter ent2 -default ent1 -defaultid 1
mkvdev -sea ent0 -vadapter ent1,ent2 -defaultid 1
mkvdev -sea ent0 -vadapter ent1 ent2 -default ent1 -defaultid 1
第21题:
ping
iostat
netstat
ifconfig
第22题:
Etherchannel and trunking
Network Interface Backup and Etherchannel
Shared Ethernet Adapter (SEA) Failover and Etherchannel
Network Interface Backup and Shared Ethernet Adapter failover
第23题:
Configure a Shared Ethernet Adapter on the Virtual I/O Server.
Use the same virtual LAN ID on each LPAR.
Set up IP routing through an LPAR on each system.
Set up an IP firewall through an LPAR on each system.