use different fire hose pressures
use fire hoses of different sizes
not attack the fire from opposite sides
not wear protective clothing
第1题:
Which of the following statements is FALSE concerning the proper procedure in handling a fire hose ________.
A.A 1.5 inch hose should be deployed with a minimum of a nozzleman and hoseman
B.Back-up hosemen should be positioned wherever the hose makes a significant turn
C.The fire hose should be partially charged before deploying it from the fire station
D.The nozzleman should always hold the nozzle with one hand on top,to prevent kickback
第2题:
Fire hose couplings ______.
A.are made of bronze brass, or soft alloy metals
B.should be painted red in order to identify hose lengths
C.are specially hardened to prevent crushing
D.should be greased frequently
第3题:
The fire pump
Exposed hard piping
The hydrant valve
The fire hose
第4题:
Call the owner,operator,or terminal supervisor
Unplug the deck scuppers
Order the dock man to shut down
Run out the vessel's or terminal's fire hose
第5题:
using a 2-1/2 inch hose
there is an outlet for the smoke and heat
the fire is totally contained by the ship's structure
at least two fog streams can be used
第6题:
secure all openings to the tank
discharge an initial charge of CO2 with a hand portable extinguisher
direct a fire hose into the tank and energize the fire main
spray the tank boundaries with a fire hose to promote cooling
第7题:
One man report the fire, and the other two men fight the fire
One man report the fire, one man fight the fire, and one man evacuate and secure the area
One man report the fire, one man fight the fire, and one man act as a safety observer
All three men fight the fire and report it immediately after it is extinguished
第8题:
glycerine
graphite
kerosene
fresh water and soap
第9题:
used only under the supervision and direction of a ship's officer
tightly capped and stowed with other tools near the job site when securing at the end of the day
used only when a pressurized fire hose is laid out ready for immediate use
in a metal container with a tight cap
第10题:
low-velocity fog
high-velocity fog
a straight stream of water
foam spray
第11题:
protect themselves from smoke
obtain the best available air
allow the heat and steam to pass overhead
All of the above
第12题:
over the top of the flames
off a bulkhead into the fire
in front of the fire
at the base of the fire
第13题:
Fire axes required on MV MODU’s must be stored in the enclosure for fire hoses with the location marked ______.
A.Fire Axe Location
B.Hose Station No. …
C.Fire Station No. …
D.Firefighting Equipment
第14题:
消防泵()
第15题:
Trip the pump relief valve
Order the dock man to shut down
Call the owner,operator,or terminal supervisor
Run out the vessel's or terminal's fire hose
第16题:
cross connection line between two main fire lines
special wrench for the couplings in a fire hose line
tackle rigged to support a fire hose
None of the above
第17题:
When attacking the fire directly
When using a steam smothering system
When using the fixed CO2 system
All of the above
第18题:
threads are lubricated
nozzle is attached to the hose
female coupling has a gasket
hose is led out
第19题:
fire hose might be damaged by cargo operations
vessel is in port
fire-main system is not charged
fire pumps are used for purposes other than supplying water to the fire main
第20题:
stop ventilation to the area
stop the vessel
secure electricity to the circuit
apply CO2 to the fire
第21题:
American Petroleum Institute
National Standard Fire hose Coupling
American Society of Mechanical Engineers
Underwriter's Laboratories,Inc
第22题:
cross connection line between two main fire lines
special wrench for tightening couplings in a fire hose line
tackle rigged to support a fire hose
None of the above
第23题:
salt water and a wire brush
caustic soap
mild soap and fresh water
a holystone