A customer had been given a proposal for a p5-570 6-way 32GB system running in Full Partition mode.  After review, the customer asked that the configuration be modified to enhance the reliability and availability of the solution.  However, the customer do

题目

A customer had been given a proposal for a p5-570 6-way 32GB system running in Full Partition mode.  After review, the customer asked that the configuration be modified to enhance the reliability and availability of the solution.  However, the customer does not want to pay for HACMP or additional machines.  What change would be most likely to improve the reliability of the solution?()

  • A、Add CUoD memory.
  • B、Provide CUoD processors.
  • C、Provide redundant disks on separate SCSI buses.
  • D、Add redundant power supplies in the p5-570 CEC (Central Electronics Complex).

相似考题
更多“A customer had been given a proposal for a p5-570 6-way 32GB system running in Full Partition mode.  After review, the customer asked that the configuration be modified to enhance the reliability and availability of the solution.  However, the customer do”相关问题
  • 第1题:

    What IBM resource helps to easily identify a business application that has been validated on IBM Systems?() NOTE:// Solutions that are in this resource represent applications that enable IBM Systems and verify, through customer experience, installing and running in a customer location.

    • A、IBM Standalone Solutions Configuration Tool (SSCT)
    • B、IBM Server Proven
    • C、IBM System x Reference Sheets (xREF)
    • D、IBM Sizing Guides

    正确答案:C

  • 第2题:

    A pharmaceutical company has a requirement for 8.5 TB of usable storage for a new data center. The customer has multiple host applications running on Solaris, Windows 2003, HP-U/X, Linux, and IBM System i platforms.  Which IBM System Storage DS8000 volume configuration providesthe best performance and highest availability for this customer()

    • A、RAID 3
    • B、RAID 5
    • C、RAID 6
    • D、RAID 10

    正确答案:D

  • 第3题:

    A customer requests a solution that will enhance the availability of their servers and ensure that the time needed to recover from an Operating System fault is at a minimum.  What solution do you recommend? ()

    • A、Use RAID protection and add more memory
    • B、Install Operating System in RAID 0 (Parity) Disk Configuration
    • C、Install Operating System in RAID 5 Disk Configuration
    • D、Use RAID protection and ensure systems are backed-up daily

    正确答案:D

  • 第4题:

    A storage specialist is proposing a solution consisting of an IBM System Storage TS3200 TapeLibrary and a SAN Volume Controller, both of which are being added to a customer’s existing SANenvironment for the first time. Which of the following should be completed before the proposal ispresented to the customer?()

    • A、TDA
    • B、Capacity Magic
    • C、business case review
    • D、SAN configuration review

    正确答案:A

  • 第5题:

    A customer needs three 2-way application servers and is evaluating the purchase of three p5-520s versus one partitioned 6-way p5-570.  They like the benefits provided with dynamic processor sparing.  What information should the pSeries technical specialist emphasize to the customer?()

    • A、The p5-570 offers CoD processors.
    • B、The p5-570 requires more rack space than the three p5-520s.
    • C、Redundant power is standard on the p5-570 and is optional on the p5-520.
    • D、Operating system charges will be less expensive with the p5-520 solution.

    正确答案:A

  • 第6题:

    A p5-570 8-way 32GB system has been proposed to a customer as a new test system with four LPARs.  The current applications are certified on AIX 5.2 but not yet on AIX 5.3.  The customer wants to understand the advantages and disadvantages of this solution versus a pair of 4-way p5-550s with 16GB each in testing their current applications. Which of the following points should the pSeries technical specialist highlight?()

    • A、The p5-570 would save rack space over a pair of p5-550 servers.
    • B、The p5-570 allows for more CPU and memory resources to be dynamically allocated to any LPAR for performance testing.
    • C、The p5-570 can only be upgraded to 64GB of RAM without replacing memory.
    • D、The p5-570 supports advanced features such as Micro-Partitioning and Virtual I/O allowing more LPARs of the customer’s applications with fewer processors and fewer I/O adapters.

    正确答案:B

  • 第7题:

    The account team designed a p5-570 solution to strategically position the customer for future IBM announcements.  The customer was dissatisfied upon implementing the solution.  An AIX v5.1 partition was added to the requirements halfway through the solution design process and it was not considered in the final design. What should the pSeries technical specialist have done to prevent this situation?()

    • A、Submitted an RPQ (Request for Quote) for AIX v5.1 support on a p5-570
    • B、Designed a p670 because it supports AIX 5.1 partitions
    • C、Initially designed a solution supporting AIX 5.1 partitions
    • D、Gained customer approval for the final design prior to ordering the system

    正确答案:D

  • 第8题:

    A customer indicates that a system is experiencing printing problems. After checking the system, and successfully printing, no problem has been found.  Which of the following procedures should be performed next to further clarify the problem?()

    • A、 Reboot the system.
    • B、 Check the file system sizes.
    • C、 Have the customer repeat the task to recreate the problem.
    • D、 Inform the customer that no problems were found, and to call back if the problem reoccurs.

    正确答案:C

  • 第9题:

    The account team is putting together a very complex solution for the customer.  During the solution design phase, many of the customer’s requirements have changed and additional requirements are being identified.  What should the pSeries technical specialist do to ensure the greatest possible customer satisfaction?()

    • A、Use eConfig to configure and validate each pSeries and p5 system.
    • B、Engage Advanced Technical Support to review any outstanding technical issues.
    • C、Confirm with the customer that the solution design meets their requirements.
    • D、Perform a Pre-Install Solution Assurance Review to validate required power requirements.

    正确答案:C

  • 第10题:

    单选题
    A customer requires an 8-way 16GB AIX system.  They are evaluating the following three systems: ? p5-570   ? p5-570 Express  ? p650   The pSeries technical specialist has been asked to explain the pros and cons of the three solutions.   What information will help the customer decide on the best solution for their environment?()
    A

    The p5-570 Express can support DDR2 memory.

    B

    The p650 and p5-570 Express provide faster processors.

    C

    The p5-570 Express is limited to eight 1.5GHz processors.

    D

    Neither the p5-570 nor the p5-570 Express supports Capacity on Demand.


    正确答案: B
    解析: 暂无解析

  • 第11题:

    单选题
    A customer left a message on the pSeries technical specialist’s voicemail that a proposal is needed for a p5-550 4-way 1.4GHz 8GB machine.  The specialist configured a p5-570 4-way 1.5GHz 8GB machine and sent it to the customer with a note that this system was the closest match to that requested.could the specialist have done to minimize any customer dissatisfaction in an efficient manner?()
    A

    A

    B

    B

    C

    C

    D

    D


    正确答案: B
    解析: 暂无解析

  • 第12题:

    单选题
    Your customer requires you to supply a configuration or proposal in xl format.  What tool is available? ()
    A

    IBM Standalone Solutions Configuration Tool (SSCT )

    B

    Server Proven

    C

    Configuration Options Guide (COG)

    D

    xREF (System X reference)


    正确答案: A
    解析: 暂无解析

  • 第13题:

    The customer has recently installed a pSeries p5-570 with EMC attached disk storage.  After installation, the customer complained that the disk access appeared to be too slow.  How should the pSeries technical specialist best assist the customer?()

    • A、Recommend the customer call EMC.
    • B、Recommend the customer call IBM hardware support.
    • C、Recommend the customer contact SupportLine.
    • D、Recommend the customer re-creates the volume groups.

    正确答案:C

  • 第14题:

    Your customer requires you to supply a configuration or proposal in xl format.  What tool is available? ()

    • A、IBM Standalone Solutions Configuration Tool (SSCT )
    • B、Server Proven
    • C、Configuration Options Guide (COG)
    • D、xREF (System X reference)

    正确答案:C

  • 第15题:

    The pSeries technical specialist just finished reviewing the system configurations with the customer. The customer requested that many of the availability options,initially configured,be removed due to budgetary constraints.   What should be done next?()

    • A、Remove the availability options,as requested, and place the systems on order.
    • B、Keep the availability options in the configurations and engage the pricer to provide deep discounting on the solution.
    • C、Remove the availability options and review the new configurations with the customer,highlighting the potential exposures.
    • D、Keep the availability options in the configurations, knowing that these options may prevent a critical situation in the future.

    正确答案:C

  • 第16题:

    A customer requires an 8-way 16GB AIX system.  They are evaluating the following three systems: ? p5-570   ? p5-570 Express  ? p650   The pSeries technical specialist has been asked to explain the pros and cons of the three solutions.   What information will help the customer decide on the best solution for their environment?()

    • A、The p5-570 Express can support DDR2 memory.
    • B、The p650 and p5-570 Express provide faster processors.
    • C、The p5-570 Express is limited to eight 1.5GHz processors.
    • D、Neither the p5-570 nor the p5-570 Express supports Capacity on Demand.

    正确答案:C

  • 第17题:

    A customer has a key application running in a logical partition on a POWER5 system. The customer wants the ability to run the application with minimal down time using Live Partition Mobility.  Which of the following is the minimum PowerVM edition and hardware configuration that will support the customer requirement?()

    • A、 PowerVM Standard Edition on POWER6 hardware
    • B、 PowerVM Standard Edition with POWER5 hardware 
    • C、 PowerVM Enterprise Edition with POWER6 hardware
    • D、 PowerVM Enterprise Edition with POWER5 hardware

    正确答案:C

  • 第18题:

    A System x sales specialist is creating a proposal for a Unix-installed account. The customer is looking to migrate several business-critical applications onto Linux running on Intel.  Which of the following should help IBM meet the customer’s requirements?()

    • A、Propose VMware with Linux on Intel as a solution.
    • B、Provide a special bid on the System x servers.
    • C、Include migration services within the proposal.
    • D、Provide a warranty offering with guaranteed fix levels.

    正确答案:C

  • 第19题:

    A Sales Specialist receives an email from a customer, requesting information on IBM’s best Server Consolidation solution. How should the Sales Specialist proceed? ()

    • A、Send the customer information on VMware
    • B、Send the customer information on IBM BladeCenter 
    • C、Call the customer to ask why they are consolidating
    • D、Send the customer information on IBM System P

    正确答案:C

  • 第20题:

    Which of the following situations would suggest to a System x Sales Specialist that the customer could benefit from an iSCSI solution?()

    • A、The customer is looking for a fibre SAN solution to increase reliability and performance.
    • B、The customer wants to implement an energy-efficient solution to comply with their Go Green initiative.
    • C、The customer is cost-conscious and is looking for a centralized storage solution.
    • D、The customer is a large telecommunications firm and is looking to centralize storage for all their System x,System p,and mainframe servers.

    正确答案:C

  • 第21题:

    What is the correct stage in the sales process for a Pre-Sales Technical & Delivery Assessment (TDA)? ()

    • A、Before the first solution design meeting with the customer
    • B、After the solution design proposal is submitted to manufacturing for review
    • C、Once the customer has supplied the solution design specifications to the sales team
    • D、After the solution design is completed and before the proposal is submitted to the customer

    正确答案:D

  • 第22题:

    单选题
    A customer indicates that a system is experiencing printing problems. After checking the system, and successfully printing, no problem has been found.  Which of the following procedures should be performed next to further clarify the problem?()
    A

     Reboot the system.

    B

     Check the file system sizes.

    C

     Have the customer repeat the task to recreate the problem.

    D

     Inform the customer that no problems were found, and to call back if the problem reoccurs.


    正确答案: D
    解析: 暂无解析

  • 第23题:

    单选题
    Which of the following situations would suggest to a System x Sales Specialist that the customer could benefit from an iSCSI solution?()
    A

    The customer is looking for a fibre SAN solution to increase reliability and performance.

    B

    The customer wants to implement an energy-efficient solution to comply with their Go Green initiative.

    C

    The customer is cost-conscious and is looking for a centralized storage solution.

    D

    The customer is a large telecommunications firm and is looking to centralize storage for all their System x,System p,and mainframe servers.


    正确答案: B
    解析: 暂无解析