During a NIM install, the system stops with the LED code 611.What is the cause of the issue?()A、A failure to NFS mount filesystems from the NIM clientB、A failure to NFS mount filesystems from the NIM masterC、A failure to retrieve the tftp client info from

题目

During a NIM install, the system stops with the LED code 611.What is the cause of the issue?()

  • A、A failure to NFS mount filesystems from the NIM client
  • B、A failure to NFS mount filesystems from the NIM master
  • C、A failure to retrieve the tftp client info from the NIM master
  • D、A failure to retrieve the tftp server info from the NIM master

相似考题
更多“During a NIM install, the system”相关问题
  • 第1题:

    An administrator is investigating why a non-prompted NIM rte install is failing after the successful netboot of the spot. A matching spot and lpp_source are correctly allocated to the NIM client in addition to a bosinst_data. What is the most likely cause of the install failure?()

    • A、The bosinst_data has an incorrect console defined.
    • B、The bosinst_data is incompatible with the level of spot.
    • C、The bosinst_data has an incorrect disk location defined.
    • D、The bosinst_data has an incorrect language option defined.

    正确答案:C

  • 第2题:

    New AIX systems arrive without a CDROM drive. All systems do not have the system hardware configuration. Which of the following options is the most appropriate way to install AIX on the systems?()

    • A、Install CDROM drives or tape drives on the systems because that is the only way to install AIX.
    • B、Install one system. Take a mksysb from the first system and resotre the mksysb to the remaining systems.
    • C、Install one system. Mirror rootvg onto a disk from each of the remaining systems.
    • D、Setup and NIM master and resources.

    正确答案:D

  • 第3题:

    For NIM to install client machines located in a non-adjacent network, which routing must be defined?()  

    • A、Boot/install servers will be required on each intermediate network.
    • B、When an install is initiated by the client, routing is only required from the LPAR back to the NIM master.
    • C、When an install is initiated by the NIM master, routing is only required from the NIM master to the client.
    • D、Appropriate network NIM resources need to be defined to the NIM master to allow routing in both directions.

    正确答案:D

  • 第4题:

    If a restore from a NIM mksysb install hung on C54, which debug output would be best to investigate the problem?()

    • A、export INST_DEBUG =yes
    • B、bosboot -aID -d /dev/ipldevic
    • C、nim - to check -a debug =yes
    • D、 type 911 at -Welcome to BOS install- menu

    正确答案:D

  • 第5题:

    Which of the following steps should be done FIRST when deploying a Virtual I/O server on a p5-550, which will host three logical partitions: a NIM server and two application servers?()

    • A、Create and install the NIM server
    • B、Create and install the Virtual I/O Server
    • C、Create and install the application servers
    • D、Activate Advanced POWER Virtualization

    正确答案:D

  • 第6题:

    What are the steps required to perform a Preservation install on a server?()

    • A、Shutdown the server and boot it into SMS.Select SMS menu option OS Upgrade,Preservation install for the install type,and allow upgrade to run
    • B、Shut down the server and perform a network boot from a local NIM server.Select Presevation install for the install type,and allow upgrade to run
    • C、Shutdown the server and boot it into SMS.Select SMS menu option OS Upgrade,Presevation install for the install type,and allow for upgrade to run
    • D、Re-boot the server and NFS mount the bos images from a local NIM server.Run smit install.Select Presevation install for the install type,and allow upgrade to run

    正确答案:A

  • 第7题:

    单选题
    New AIX systems arrive without a CDROM drive. All systems do not have the system hardware configuration. Which of the following options is the most appropriate way to install AIX on the systems?()
    A

    Install CDROM drives or tape drives on the systems because that is the only way to install AIX.

    B

    Install one system. Take a mksysb from the first system and resotre the mksysb to the remaining systems.

    C

    Install one system. Mirror rootvg onto a disk from each of the remaining systems.

    D

    Setup and NIM master and resources.


    正确答案: D
    解析: 暂无解析

  • 第8题:

    单选题
    A System p administrator plans to install a new system with AIX 5.3 TL5 using a NIM server.  Which of the following provide post install diagnostics()
    A

    SPOT

    B

    lpp_source

    C

    mksysb

    D

    install CD


    正确答案: A
    解析: 暂无解析

  • 第9题:

    单选题
    During a NIM install,the system stops with the LED code 611.What is the cause of the issue?()
    A

    A failure to NFS mount filesystems from the NIM client

    B

    A failure to NFS mount filesystems from the NIM master

    C

    A failure to retrieve the tftp client info from the NIM master

    D

    A failure to retrieve the tftp server info from the NIM master


    正确答案: D
    解析: 暂无解析

  • 第10题:

    单选题
    If a restore from a NIM mksysb install hung on C54, which debug output would be best to investigate the problem?()
    A

    export INST_DEBUG =yes

    B

    bosboot -aID -d /dev/ipldevic

    C

    nim - to check -a debug =yes

    D

    type 911 at -Welcome to BOS install- menu


    正确答案: B
    解析: 暂无解析

  • 第11题:

    After updating the system, the system administrator runs the lppchk-v command. During this process, the bos.rte.libc is in a broken state. Which of the following procedures should be performed to fix this problem?()

    • A、Reinstall the system
    • B、Use installp -r to reject the broken fileset
    • C、Use installp -acgFXd to reinstall the fileset at the same level
    • D、Use install -u to remove this broken fileset and reinstall it again

    正确答案:C

  • 第12题:

    What are the minimal resources to perform a NIM BOS install?()

    • A、spot, lpp_source
    • B、mksysb, lpp_source
    • C、boot, bundle, nim_script
    • D、aix disks, spot, lpp_source

    正确答案:A

  • 第13题:

    A system administrator needs to quickly migrate a machine from AIX 5.1 to AIX 5.2. The administrator will only be allowed enough downtime to reboot the machine. Which installation method should be used to accomplish this task?()

    • A、Perform a migration installation during the reboot process.
    • B、Perform an alternate disk installation and migration using NIM.
    • C、Copy the /usr directory from another 5.2 server to this server.
    • D、Perform an update_all install from 5.2 media to take effect on reboot.

    正确答案:B

  • 第14题:

    What are the steps required to perform a Preservation install on a server?()

    • A、Shutdown the server and boot it into SMS.Select SMS menu option OS Upgrade, Preservation install for the install type, and allow upgrade to run.
    • B、Shut down the server and perform a network boot from a local NIM server. Select Preservation install for the install type, and allow upgrade to run.
    • C、Shutdown the server and boot it into SMS.Select SMS menu option OS Upgrade, Preservation install for the install type, and allow for upgrade to run.
    • D、Re-boot the server and NFS mount the bos images from a local NIM server. Run smit install. Select Preservation install for the install type, and allow upgrade to run.

    正确答案:A

  • 第15题:

    An administrator migrates from AIX 5.3 to AIX 6.1. Upon completion, a client questions why files are missing from /tmp. How should the administrator respond to the client?()

    • A、Explain that the files never existed in the first place.
    • B、Explain that during a Migration install the /tmp filesystem is overwritten.
    • C、Explain that after a Migration install, all system filesystems will be empty.
    • D、Explain that /tmp is temporary storage and files are automatically removed every 30 days.

    正确答案:B

  • 第16题:

    Which of the following BEST describes the initial process of setting up a new operating system from a CD-ROM? ()

    • A、Format a partition, install device drivers, and install the operating system.
    • B、Create a partition, format the partition, and install the operating system.
    • C、Install the operating system, create a partition, and install device drivers.
    • D、Install the operating system, install device drivers, and create a partition.

    正确答案:B

  • 第17题:

    单选题
    Company.com  with limited AIX skills has purchased a p5-520 2-way which will run Micro-Partitions. To reduce the initial cost of purchase, the customer will be sharing the system resources using a VIO server. The customer is concerned about managing the installation of the operating system. Which of the following should the customer perform?()
    A

    Use alt_disk_install to install AIX on all logical partitions.

    B

    Configure the DVD as a desired resource on all partitions.

    C

    Configure all resources as shared resources between all partitions.

    D

    Create a separate NIM server to manage the installation of all partitions.


    正确答案: A
    解析: 暂无解析

  • 第18题:

    单选题
    Which of the following BEST describes the initial process of setting up a new operating system from a CD-ROM? ()
    A

    Format a partition, install device drivers, and install the operating system.

    B

    Create a partition, format the partition, and install the operating system.

    C

    Install the operating system, create a partition, and install device drivers.

    D

    Install the operating system, install device drivers, and create a partition.


    正确答案: B
    解析: 暂无解析

  • 第19题:

    多选题
    A server technician has been attempting to install an operating system on the company test server for several days. The technician has experienced error messages at several points of theinstallation and the system has frozen during various parts of the boot process. The technician has replaced the power supply, graphics card and installation disk with known good components.Which of the following could be causing these issues?()
    A

    Storage driver not loaded

    B

    Fragmented hard drive

    C

    Damaged or faulty NIC chipset

    D

    Damaged or faulty system board

    E

    Memory incompatible with the processor

    F

    Missing voltage regulator


    正确答案: C,E
    解析: 暂无解析