A SAN needs to undergo disruptive maintenance, which will effect a hosted production system with multiple applications and related volume groups, one of which, datavg, resides on the SAN. There is one spare disk in the system but it is smaller than datav

题目

A SAN needs to undergo disruptive maintenance, which will effect a hosted production system with multiple applications and related volume groups, one of which, datavg, resides on the SAN. There is one spare disk in the system but it is smaller than datavg. How can application outages and risk of corruption be minimized?()

  • A、Stop the applications in all data volume groups and shut the system down during the outage period.
  • B、Stop the applications in datavg, unmount all datavg filesystems, varyoff datavg, and export datavg.
  • C、Stop the applications in datavg, unmount all datavg filesystems, and reduce datavg by the SAN disks.
  • D、Use the 'cpvg' command with the -z option to copy and compress datavg to different physical volumes.

相似考题
更多“A SAN needs to undergo disrupti”相关问题
  • 第1题:

    SAN存储组网中,FC-SAN和IP-SAN的对比,错误的是()

    • A、FC-SAN性能更好,但相对昂贵
    • B、IP-SAN可扩展性较好
    • C、FC-SAN在长距离传输上具有优势
    • D、FC-SAN需要光纤交换机,IP-SAN使用常规IP网络设备即可

    正确答案:C

  • 第2题:

    My car()

    • A、needs towash
    • B、needs wash
    • C、needs washing
    • D、needs being washed

    正确答案:C

  • 第3题:

    下列关于IP-SAN描述正确的是()

    • A、IP-SAN存储是基于IP网络来实现块级数据存储的方案
    • B、IP-SAN存储系统具备易部署,高可靠性和高客扩展性特点
    • C、IP-SAN存储适用本地iSCSIinitiator通过IP网络与iSCSItarget建立SAN网络
    • D、IP-SAN存储系统大大节省了投资资本,得到越来越广泛的应用,逐步取代FC-SAN

    正确答案:A,B,C

  • 第4题:

    A prospective client needs to combine Ethernet, FCOE, and iSCSI.  They have not been able to practically combine these in the past. Which of the following IBM products meets this need?()

    • A、BladeCenter Open Fabric Manager (BOFM) 
    • B、SAN Volume Controller (SVC) 
    • C、Virtual Fabric for BladeCenter 
    • D、Network Provisioning on Demand in the AMM 

    正确答案:C

  • 第5题:

    Which network technology addresses these customer business needs: shrinking budgets and IT staffs, more complex networks, and an increased need for network security?()

    • A、Optical network
    • B、Storage-area network (SAN)
    • C、Content delivery network (CDN)
    • D、Network management

    正确答案:D

  • 第6题:

    Where are SAN Port Channel is created in UCS Manager?()

    • A、 Under the Admin tab on the FI
    • B、 Under the Server tab in the service profile
    • C、 Under the SAN tab on each VSAN
    • D、 Under the Admin tab on the chassis
    • E、 Under the SAN tab on the Fabric Interconnect

    正确答案:E

  • 第7题:

    A customer is planning a combined solution of a 2 node SVC and DS8700 with 128x300 GB FC disks. During the TDA the reviewer compares the machine configuration with the customer’s expectations.  Which of the following customer requirements must be considered()

    • A、the number of SAN ports required by the solution
    • B、thin provisioning is mandatory
    • C、the solution needs to support RAID 0
    • D、the solution needs to be supported by the VMware Site Recovery Manager

    正确答案:A

  • 第8题:

    A customer has a combination of fifteen Windows file servers with direct attached storage and three Power Systems with AIX database servers SAN attached to a DS4700.  They would like to upgrade and plan for 40 TB capacity.  The customer needs to move to a more scalable storage system to include all servers.Which of the following would be most appropriate to ask first?()

    • A、What are the plans for Disaster Recovery? 
    • B、What are the plans for data migration? 
    • C、Would iSCSI meet your needs? 
    • D、How much space is available in the current storage systems?

    正确答案:B

  • 第9题:

    A new LPAR has been created that needs SAN attached disk for a database. After AIX has been installed, the fibre cables are attached to the adapters. How should the administrator configure the disks?()

    • A、Run 'mkdev' to force the FC adapter to log into the SAN, have the SAN LUNs zoned to the server, run 'cfgmgr' to discover and configure the disks.
    • B、Run 'mkpath' to force the FC adapter to log into the SAN, have the SAN LUNs zoned to the server, run 'cfgmgr' to discover and configure the disks.
    • C、Run 'chpath' to force the FC adapter to log into the SAN, have the SAN LUNs zoned to the server, run 'cfgmgr' to discover and configure the disks.
    • D、Run 'cfgmgr' to force the FC adapter to log into the SAN, have the SAN LUNs zoned to the server, run 'cfgmgr' to discover and configure the disks.

    正确答案:D

  • 第10题:

    A customer has a combination of fifteen Windows file servers with direct attached storage and three Power Systems with AIX database servers SAN attached to a DS4700. They would like to upgrade and plan for 40 TB capacity. The customer needs to move to a more scalable storage system to include all servers. Which of the following would be most appropriate to ask first?()

    • A、What are Disaster Recoveryplans
    • B、What are plans for datamigration
    • C、What storage system space isavailable
    • D、DoesiSCSI meet the needs

    正确答案:B

  • 第11题:

    单选题
    An administrator needs to load additional disk drivers on the VIOS in order to attach to the SAN. Which of the following will enable this?()
    A

     run updateios 

    B

     run cfgdriver 

    C

     run oem_setup_env 

    D

     run driver_install 


    正确答案: B
    解析: 暂无解析

  • 第12题:

    多选题
    下列关于IP-SAN描述正确的是()
    A

    IP-SAN存储是基于IP网络来实现块级数据存储的方案

    B

    IP-SAN存储系统具备易部署,高可靠性和高客扩展性特点

    C

    IP-SAN存储适用本地iSCSIinitiator通过IP网络与iSCSItarget建立SAN网络

    D

    IP-SAN存储系统大大节省了投资资本,得到越来越广泛的应用,逐步取代FC-SAN


    正确答案: D,A
    解析: 暂无解析

  • 第13题:

    My car()

    • A、needs to wash
    • B、needs washing
    • C、needs being washed
    • D、need swash

    正确答案:B

  • 第14题:

    关于SAN描述正确的是()

    • A、SAN里面可以有很多个存储设备
    • B、SAN网络中可以有很多台服务器
    • C、SAN架构可伸缩性强,可以和NAS结合使用
    • D、SAN架构是目前应用最广泛的存储架构

    正确答案:A,B,C,D

  • 第15题:

    An administrator needs to load additional disk drivers on the VIOS in order to attach to the SAN. Which of the following will enable this?()

    • A、 run updateios 
    • B、 run cfgdriver 
    • C、 run oem_setup_env 
    • D、 run driver_install 

    正确答案:C

  • 第16题:

    以下关于FC SAN与IP SAN的比较,说法正确的有()。

    • A、两者拥有基本相同的特性,又有差异
    • B、FC SAN是高性能的保证,而IP SAN在经济性方面优势更明显
    • C、FC SAN信号传输校验方式不可靠,而IP SAN相对较可靠
    • D、FC SAN传输延时高,而IP SAN相对较低

    正确答案:A,B

  • 第17题:

    Which network technology addresses these customer business needs: shrinking budgets and IT staffs, more complex networks, and an increased need for network security?()

    • A、Optical network
    • B、Network management
    • C、Storage-area network (SAN)
    • D、Content delivery network (CDN)

    正确答案:B

  • 第18题:

    An administrator needs to connect servers to the Fiber Channel SAN. Which of the following should the administrator install in the servers to allow this connection?()

    • A、Riser
    • B、HBA
    • C、SCSI card
    • D、SAS card

    正确答案:B

  • 第19题:

    A retail company needs to add more servers to their Citrix farm.  They are considering 1U servers and High End Enterprise Servers. Their current need is internal storage only, with the possibility to attach to a SAN later.  Which TWO of the following features of the IBM x366 would exceed the 1U server’s capabilities?()

    • A、Ability to add expansion cards
    • B、More Citrix users per server reduces management costs
    • C、Ability to run on both 110V and 220V power input
    • D、Ease of deployment due to infrastructure integration
    • E、Physical sharing of the SCSI Storage Expansion Unit
    • F、Fewer cables and better cable management due to modular switches
    • G、Integrated HBAs for SAN connectivity

    正确答案:A,B

  • 第20题:

    A prospective client needs to combine Ethernet, FCOE, and iSCSI.They have not been able to practically combine these in the past.Which IBM products meets this need of the following?()

    • A、BladeCenter Open Fabric Manager (BOFM)
    • B、SAN Volume Controller (SVC)
    • C、Virtual Fabric forBladeCenter
    • D、Network Provisioning on Demand in the AMM

    正确答案:C

  • 第21题:

    A customer needs to deploy a SAN and connect nine servers running a mix of Windows and Linux.  They currently need 12TB, but their growth requirements will be tripled in the near future.  They will also consolidate 18 legacy Windows servers onto one system using virtualization software and connect that server to the storage solution.  A DS4000 series backup solution needs to be included in the design.  Which of the following solutions will satisfy these requirements?()

    • A、DS4300 with a switched fabric and an x445 running VMWare ESX server
    • B、DS4500 with a switched fabric and an x445 running VMWare ESX server
    • C、DS4300 SAN with a switched fabric and an x445 running Microsoft Virtual Server
    • D、DS4400 Server with an x445 running Virtuozzo VPS

    正确答案:B

  • 第22题:

    A stock exchange needs extremely low latency in their disk subsystem. Which disk storage technology is mostlikely to fulfill their need?()

    • A、SSD
    • B、SSA
    • C、SAS
    • D、SAN

    正确答案:A

  • 第23题:

    单选题
    在筒形活塞柴油机运转中,其曲轴箱油的有机酸与SAN变化是()。
    A

    有机酸与SAN均增加强酸

    B

    有机酸增加,SAN减小

    C

    有机酸减小,SAN增加

    D

    有机酸与SAN均减小


    正确答案: C
    解析: 在筒形活塞柴油机使用过程中,滑油一方面由于含硫燃料的燃烧产物漏入曲轴箱而生成硫酸,另一方面由于滑油中的有机酸在长期储存和使用中受到氧化作用,而使滑油的总酸值(TAN)增加