A system was rebooted and is taking a long time toreturn. The administrator has logged into the HMC and sees reference code 0c9. What does this mean?()
第1题:
A just announced two-port Ethernet card has been installed on a system and it is not recognized. On the HMC the slot shows empty. The device driver has been installed and cfgmgr runs normally. What is the most appropriate action to solve this problem?()
第2题:
A system administrator has just installed a new maintenance level, but "oslevel -r" does not show the correct maintenance level. What command can be used to determine which filesets are downlevel?()
第3题:
What is the likely cause of a system hanging at boot code 557()
第4题:
An administrator is installing AIX 6.1 on a new LPAR and the boot sequence has stalled with reference code 0c31. What is the most likely cause?()
第5题:
A system administrator for a business recovery service center needs to test disaster recovery strategies for their clients running Linux. Each client has a different system configuration. Each time a client comes in, the system configuration of the managed system must change. What is the best way to handle this using LPAR?()
第6题:
A system administrator needs to configure dump devices for the system. Which command would be used to estimate the size required for a dump device?()
第7题:
A system was rebooted and is taking a long time to return. The administrator has logged into the HMC and sees reference code 0c9. What does this mean()?
第8题:
A customer currently has five partitioned POWER4 systems and is adding new systems. When the pSeries technical specialist introduces the first p5 system with CoD into this environment, how should the HMC be handled?()
第9题:
adding small amounts of oil to the system
the system has been overheated
the system has been drained and then filled with new oil
the system has been idle for a long period of time
第10题:
The dump was successful.
A system dump is in progress.
No system dump device configured.
There was an I/O error during the dump.
第11题:
The system is configuring a device.
A system initiated dump has started.
The system is varyingon a volume group.
The system is running an inbuilt self test.
第12题:
An administrator has added a new device to a system and wants to determine if it has been correctly added to the ODM database. Which command would the system administrator use?()
第13题:
A sales team has proposed an IBM System Storage DS8100 configured with 10 TB, split equallybetween IBM System z and IBM System p. The System z environment requires point-in-time copyand the System p environment does not. For the System z environment, 3 TB have beenconfigured with an additional 2 TB for point-in-time copy. What is the least expensive licensescope for point-in-time copy?()
第14题:
After a system has rebooted from a system crash, which of the following commands should be run to find the location of the dump?()
第15题:
A system dump has occured. The LED display shows 0c0. What does this indicate?()
第16题:
A new application has been added to a system which needs to automatically be started at system startup. The system administrator has decided to accomplish this by using the /etc/inittab file. Which command would be used to accomplish this in a supported manner?()
第17题:
A system administrator has been asked to document the hardware configuration of a system. Which command can be used to assist in this task?()
第18题:
A system administrator is monitoring a system that has recently shown a decrease in performance.The administrator suspects that the system may be low on memory and may be paging excessively.Which of the following commands is best to identify a possible paging problem?()
第19题:
It is a hardware problem caused by the power failure.
There is a network problem, most probably with name resolution.
Sine the system was never rebooted, devices are marked defined instead of available and need to be activated.
Some filesets may be marked as broken and need to be reinstalled.
第20题:
The system is configuring a device.
A system initiated dump has started.
The system is varyingon a volume group.
The system is running an inbuilt self test.
第21题:
The system is configuring network adapters.
The system is configuring fibre channel devices.
The system is unable to mount the rootvg filesystems.
The system is unable to access the installation media.
第22题:
lsvg -l rootvg
sysdumpdev -e
sysdumpdev -L
cd /var/adm/ras