Which of the following is a true statement when promiscuous mode is enabled on an Integrated Virtual Ethernet?()
第1题:
A customer is planning to buy a two enclosure Power 770, and will implement 4 LPARs with the following requirements:Each LPAR must have a private, dedicated connection to the network.The adapter for this network connection must be hot-swappable.The customer wants to minimize the number of I/O slots used. Which of the following fulfills the customer requirements?()
第2题:
A customer has a 4-core POWER6 570 with 4 partitions and a 2-port 1Gbps Integrated Virtual Ethernet (IVE) Adapter. They are having problems with throughput on the Ethernet adapter and want to improve performance. Which of the following solutions will help the customer with this issue for the least cost and with the least interruption?()
第3题:
When creating a Virtual Ethernet adapter, which of the following steps is done FIRST?()
第4题:
The administrator of a Power 595 server is required to concurrently host LPARs for two different customers. Both customers’ LPARs have the same VLAN ID and subnet range, but their traffic must be isolated from each other. Which feature within the system would provide this functionality?()
第5题:
An administrator has a Power 570 in default configuration with a 4 port 1 Gbps Integrated Virtual Ethernet (IVE) adapter. A new application requires that the MCS value for the first port group of the IVE adapter be set to 1. If this change is made, what is the maximum number of logical ports, across both port groups, that the IVE adapter can provide?()
第6题:
Which of the following allows the user to have two separate Ethernet networks share the same network adapter?()
第7题:
Generate a unique MAC address.
Run cfgmgr to create device special files.
Create a virtual device with smitty vlan.
Add a virtual Ethernet adapter to the partition profile.
第8题:
Order a 2-port 1Gbps Ethernet LAN adapter.
Order a 2-port 10Gbps Ethernet LAN adapter.
Upgrade the IVE adapter to a 4-port 1Gbps IVE adapter.
Upgrade the IVE adapter to a 2-port 10Gbps IVE adapter.
第9题:
2
4
8
16
第10题:
A virtual Ethernet adapter can only connect to other partitions within the same system.
A virtual Ethernet adapter needs to be connected to an external VLAN capable switch to be able to communicate with other partitions on the same system.
A partition can support an unlimited number of virtual Ethernet devices.
A virtual Ethernet adapter in the VIO Server that is part of a SEA should not have the trunk flag set
第11题:
Etherchannel and trunking
Network Interface Backup and Etherchannel
Shared Ethernet Adapter (SEA) Failover and Etherchannel
Network Interface Backup and Shared Ethernet Adapter failover
第12题:
mkvdev -sea ent2 -vadapter ent0 -default ent0 -defaultid 1
mkdev -virtual ent0 -adapter ent3 -default en2 -defaultid 1
mkvdev -sea ent0 -vadapter ent2 -default ent2 -defaultid 1
mkvdev ent0 -sea -vadapter ent2 -default ent2 -defaultid 1
第13题:
When configuring a dual port gigabit Integrated Virtual Ethernet adapter (IVE), what value must be assigned to Multiple Core Scaling (MCS) to enable 8 logical ports in total? ()
第14题:
What type of configuration can provide the best availability in a Virtual IO Server environment?()
第15题:
Company.com has two POWER5 servers. They want the two servers’ virtual Ethernets to appear on the same IP subnet. Which of the following will connect the client virtual Ethernet adapters to the physical Ethernet switch connecting the two servers?()
第16题:
A technical specialist defined a virtual Ethernet ent2 on the VIO server that has a physical adapter, ent0. Which of the following commands should be used to configure the Shared Ethernet Adapter?()
第17题:
Company.com has a VIO server with a configured virtual Ethernet adapter and a physical Ethernet adapter with an IP address on their local public network. They want to re-configure the physical Ethernet adapter as Shared Ethernet Adapter. When the mkvdev command is run, the following method error is returned: /usr/lib/methods/cfgsea . Which of the following will most likely resolve the problem?()
第18题:
When configuring Shared Ethernet Adapter (SEA) failover between two VIO servers, which of the following attributes must have a different value on both VIO servers?()
第19题:
Run cfgdev on the VIO server and re-run the mkvdev command.
Run chdev -a sea_enable=yes on the physical Ethernet adapter.
Remove and re-add the virtual Ethernet adapter.
Remove the IP address from the physical adapter and re-run the mkvdev command.
第20题:
1
7
15
31
第21题:
4
16
20
32
第22题:
HA Mode
Trunk priority
Control Channel
Default VLAN ID
第23题:
Configure a Shared Ethernet Adapter on the Virtual I/O Server.
Use the same virtual LAN ID on each LPAR.
Set up IP routing through an LPAR on each system.
Set up an IP firewall through an LPAR on each system.